Kamco CF40 Evolution Safety & Operating Manual

Central heating power flushing pumps
Hide thumbs Also See for CF40 Evolution:

Advertisement

Quick Links

CLEARFLOW CENTRAL HEATING POWER FLUSHING PUMPS - SAFETY & OPERATING GUIDE
Central Heating
Power Flushing Pumps
CF40 Evolution & CF90 Quantum
GENERAL SAFETY AND GUIDANCE
Do not commence using this power flushing pump
until you have read these instructions fully. Ask for
clarification if you do not fully understand its use and
application.
It is the user's responsibility to ensure that this pump
is suitable for the work to be carried out, and to wear
suitable personal protective equipment.
This pump weighs more than 10kg and should
only be lifted by the handle when empty.
Do not move or drag the pump by its power
cable or the hoses.
ELECTRICAL SAFETY GUIDANCE
230 volt models are fitted with a 13 ampere plug and
may be operated from a standard 230 volt 13 ampere
power supply.
110 volt models must only be operated through a 110
volt transformer of the correct rating to avoid damage
to the motor.
Always use an RCD or plug the pump into a mains socket
protected with a built in RCD.
Switch the power flushing pump and the power supply off
before plugging into the mains electricity supply.
Always switch off the power flushing pump and isolate it
from the power supply when leaving it unattended.
OVERVIEW OF PUMP LAYOUT
Motor
Combined isolating
& dump valves
Tank
Fresh water
connection
Dump hose
connection
Flow & return
Overflow
connection
Flow reverser
lever
Water inlet valve
ON/OFF switch
Combined isolating
& dump valves
Filler cap
Maximum level
Minimum level
Carry handle
Wheels

Advertisement

loading

Summary of Contents for Kamco CF40 Evolution

  • Page 1 CLEARFLOW CENTRAL HEATING POWER FLUSHING PUMPS - SAFETY & OPERATING GUIDE Central Heating Power Flushing Pumps CF40 Evolution & CF90 Quantum GENERAL SAFETY AND GUIDANCE OVERVIEW OF PUMP LAYOUT Do not commence using this power flushing pump Water inlet valve until you have read these instructions fully.
  • Page 2 Alternatively, use a Kamco CP2 system off. Make a note of the location of each radiator and its pump head adaptor.
  • Page 3 this stage is the chemical added so that it can then work water supply inlet valve once the water level in the tank has specifically to disturb, loosen and dissolve more stubborn stabilised between minimum and maximum marks. accumulations of debris.The chemical can then work Bleed all radiators to expel any air.
  • Page 4 Set the pump to normal re-circulation mode, then with the unit Re-instating the system running, add the corrosion inhibitor to the reservoir. Allow the Reconnect any removed radiator or disconnected boiler or chemical to circulate through the system for about 10 minutes, pump.

This manual is also suitable for:

Cf90 quantum