Kenwood CS-5130 Instruction Manual page 6

40mhz dual trace readout oscilloscope
Hide thumbs Also See for CS-5130:
Table of Contents

Advertisement

CS-5130
CS-5135
READOUT
Set Value
CH1/CH2 scale factor (with probe detec-
tion); V-UNCAL, ADD, INVERT
A/B sweep scale factor (magnification con-
version): SWEEP-UNCAL, AFTER DELAY,
TRIG' D, X-Y
Cursor Mode
A mode only
AV1
Voltage
difference
between
AREF
and
Acursors on a CH1 scale factor basis
AV2
(=
Voltage
difference
between
AREF
and
Acursors on a CH2 scale factor basis
AT
Time difference between AREF and Acur-
sors on the basis of A sweep scale factor
V/AT
Frequency between AREF and Acursors on
the basis of A sweep scale factor
NOTE: The X-Y mode allows AV1 measurement only.
Cursor
Resolution
Meas-
Measurement
urement | accuracy
Measurable range
Ratio:
Voltage and time ratio between
AREF
and
Acursors,
supposing
5-division on the CRT as 100%
Phase:
Phase difference between AREF
and Acursors,
supposing
5-divi-
sion on the CRT as 360°
10 bits
+4%
AV, Ratio: + 3.6 div or more from the CRT
center
AT, 1/AT, Ratio, Phase: + 4.6 div or more
from the CRT center
TRACE ROTATION
(Electrical, adjustable from front panel)
POWER REQUIREMENT
Line Voltage
100 V/120 V/220
V +10%, 216 V—250 V
Line Frequency
50/60 Hz
Power Consumption
Approx. 47 W
|
Approx. 41 W
DIMENSIONS
(WxHxD)
319 (341) x 132 (145)
x 380 (455) mm ~
(__) dimensions include protrusion from basic outline dimensions
WEIGHT
9.0 kg
|
8.5 kg
ENVIRONMENTAL
Within Specifications
10°C to 35°C, 85% max. relative humidity
Full Operation
O°C to 40°C, 85% max. relative humidity
ACCESSORIES SUPPLIED
Probe
PC-33 (READOUT compatible probe) x 2 |
PC-30 x 2
Attenuation
1/10
1/1, 1/10
Input impedance
10 MQ, 25 pF +10%
1 MQ, 200 pF or less
10 MQ, 22 pF +10%
Power supply cable
1
Replacement Fuse
1Ax2,0.5Ax2
Instruction Manual
1
* Circuit and rating are subject to change without notice due to developments in technology.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cs-5135

Table of Contents