Figure 5-16 Connecting the power cable of the tracking system
----End
Connecting the Power Cable to the AC Terminal Block
You need to prepare the M10 OT terminal before installing the power cable of the tracking
system to the AC terminal block.
Step 1 Remove the sealing nut from the cable gland.
Step 2 Prepare a cable.
Step 3 Route the cable through the cable gland.
Step 4 Connect the power cable of the tracking system.
Connect the OT/DT terminal of the AC output cable and the OT terminal of the
power cable of the tracking system to the AC terminal block with the latter placed
on top of the former. Ensure that the terminals are separated in the wiring area
and are connected securely.
Step 5 Tighten the cable gland.