Philio PAN44 Manual

Smart energy plug
Hide thumbs Also See for PAN44:

Advertisement

Quick Links

Smart Energy Plug PAN44
This plug-in ON/OFF switch PAN44 is a devices displaying the Z-Wave Plus
also be used security enabled wireless switch, based on Z-Wave Plus
Wave Plus
TM
enabled with it regardless of the manufacturer, and can also be used in
other manufacturer's Z-Wave
TM
enabled networks. Remote On/Off control of the con-
nected load is possible with another manufacturer's wireless Controller. Each switch is
designed to act as a repeater. Repeaters will re-transmit the RF signal to ensure that the
signal is received by its intended destination by routing the signal around obstacles and
radio dead spots. Because PAN44 supports Security Command Class, it can learn with
Secured controller. Its functionality and supported command classes are identical when
included as a secure and non-secure device.
This plug-in ON/OFF switch is able to detect instance wattage (1560W/UL/TW/JP) and
overload current (14.5A with resistive load) of connected lights or appliances. When de-
tecting overload state, the Switch will be disabled and it's On/Off button will be lockout
of which LED will flash quickly. However, unplug and reconnect the switch will reset its
overload condition to normal status.
Specification
Operating Voltage
Maximum Load (Ampere)
Range
Operating Temperature
Frequency Range
RF Maximum Power
** Specifications are subject to change and improvement without notice.
Troubleshooting
Symptom
TM
logo can
The Switch not working
TM
technology. Z-
and LED off
The Switch LED illumi-
nating, but cannot control
the Switch of the load at-
tached
The Switch LED illumi-
nating, but the Detector
cannot control the Switch
LED keep flashing, but
cannot control
100V-240V~ 50Hz~60Hz
13A (Resistive load) PAN44-1; PAN44-2
Minimum 40 m in door 100m outdoor line of sight
0°C ~ 40°C
908.4MHz & 916.0MHz/ USA (PAN44-1);
920~927MHz/ Taiwan/ Japan (PAN44-2)
+10dBm (Peak), -10dBm (Average)
Cause of Failure
1.The Switch is not plugged into
1. Check power connections
the electrical outlet properly
2. Don't open up the Switch
2.The Switch break down
and send it for repair.
1. Set the ON/OFF switch of
1.Check if the load plugged into
the load attached to ON
the Switch has its own ON/OFF
2. Unprotected the switch or
switch
follow the instruction of pro-
2. The switch is protected
tection.
1. Not carry out association
1. Carry out association
2. Same frequency interference
2. Wait for a while to retry
Remove the load attached or
Overload occurs
check max. load cannot ex-
ceed 13A (Resistive load)
Recommendation

Advertisement

loading
Need help?

Need help?

Do you have a question about the PAN44 and is the answer not in the manual?

Questions and answers

Summary of Contents for Philio PAN44

  • Page 1 2. The switch is protected tection. radio dead spots. Because PAN44 supports Security Command Class, it can learn with The Switch LED illumi- Secured controller. Its functionality and supported command classes are identical when 1. Not carry out association 1.
  • Page 2 For Instruction to http://www.philio-tech.com Adding to Z-Wave Network In the front casing, there is an on/off button with LED indicator below which is used to toggle switch on and off or carries out inclusion, exclusion, reset or association. When first power is applied, its LED flashes on and off alternately and repeatedly at 2 second intervals.
  • Page 3: Led Indication

    NIF for associations, then pressing 3. Without further actions, PAN44 the On/Off button three times within will be automatically included in a 2 seconds will cause the PAN44 to certified Z-Wave™ Controller with send its NIF. SmartStart inclusion ability in 10 2.There is only one group for the...
  • Page 4: Installation

    Learning When PAN44 is in learning mode, LED flashes on and off alternately 1-1 BASIC_GET / BINARY_SWITCH_GET and repeatedly at 0.5 second intervals. Upon receipt of the following commands from a Z-Wave™ Controller, the Overload When overload state occurs, the Switch is disabled of which LED Switch will report its On/Off state to the node asked.
  • Page 5 2-2-2 Accumulated Power Consumption (KWh) When receiving Meter Get Command, it will report Meter Report Command to 2-1-3 Overload alarm report When PAN44 detects the current is more than 14.5A, it will send Alarm Report the node. to Lifeline Group node.
  • Page 6 Meter Value 1 = 0x09(V) Precision = 2,Scale = 0x00,Size = 4,Meter Value (KWh)] Meter Value 2 = 0x01(V) Example: AC load Voltage = (Meter Value 1*256) +(Meter Value 2)= 230.5 (V) Scale = 0x00 (KWh) Precision = 2 2-2-5 AC load current ( I ) Size = 4 Bytes (KWh) When receiving Meter Get Command, it will report Meter Report Command to Meter Value 1 = 0x00(KWh)
  • Page 7 3-2 KWH Meter Report Period: Report Period 1~32767: 0x7FFF If the setting is configured for 1 hour (set value =6), PAN44 will report its Ac- 10min~ 227days cumulated Power Consumption (KWh) to Lifeline Group node every 1 hour. Threshold of 1300*0.01A...
  • Page 8 3-8 Watt differential mode:The default setting is 1 (= 5%). Binary Switch Highest granted Security Class Whenever Watt value of PAN44 changes over 5% of last reading value, it will Configuration Highest granted Security Class send Meter report to the Lifeline Group nodes. However, if Watt differential...
  • Page 9 FCC Caution: Any changes or modifications not expressly approved by the party respon- sible for compliance could void the user's authority to operate this equipment. Company of License Holder:Philio Technology Corporation Address of License Holder :8F., No.653-2, Zhongzheng Rd., Xinzhuang Dist., This transmitter must not be co-located or operating in conjunction with any other an- New Taipei City 24257, Taiwan(R.O.C)