Philio PAN16 Quick Start Manual

Philio PAN16 Quick Start Manual

Smart energy plug in switch

Advertisement

PAN16
Smart energy plug in switch
Introduction
This plug-in ON/OFF switch PAN16 is a security enabled wireless switch, based on
Z-Wave Plus technology. Z-Wave Plus
TM
Plus
logo can also be used with it regardless of the manufacturer, and can also be
used in other manufacturer's Z-Wave
the connected load is possible with other manufacturer's wireless Controller. Each
switch is designed to act as a repeater. Repeaters will re-transmit the RF signal to
ensure that the signal is received by its intended destination by routing the signal
around obstacles and radio dead spots. Because PAN16 supports Security Command
Class, it can learn with Secured controller. Its functionality and supported command
classes is identical when included as a secure and non-secure device.
This plug-in ON/OFF switch is able to detect instance wattage (3000W/230Vac)
(13Ampere) and overload current (14.5A with resistive load) of connected lights or
appliances. When detecting overload state, the Switch will be disabled and its On/Off
button will be lockout of which LED will flash quickly.
re-connect the switch will reset its overload condition to normal status.
TM
enabled devices displaying the Z-Wave
TM
enabled networks. Remote On/Off control of
However, unplug and
Warning:
1.Plug out to disconnect from power supply; Do not plug in line.
2. Do not exceed the max rating.
Warnung:
1.Trennen Sie das Gerät von der Stromzuführung. Verwenden Sie das Gerät nicht mit
einem DIP Schalter.
2. Achten Sie darauf, dass die maximale Spannung niemals überschritten wird.
Warnung:
für zwischenstecker:
nicht hintereinander stecken
Specification
Rated Voltage
100V-240Vac 50Hz-60Hz 13A
Maximum Load (Ampere) 13A (Resistive load)
PAN16-1; PAN16-2; PAN16-3
Maximum Load (Ampere) 10A (Resistive load)
PAN16-4 (Switzerland)
Germany type: PAN16-1
Socket Type:
France type: PAN16-2
UK type: PAN16-3
Switzerland type: PAN16-4
Range
Minimum 40 m in door 100m outdoor line of sight
Operating Temperature
0° C - 40° C
Frequency Range
868.40MHz & 869.85MHz for EU (PAN16-1/-2/-3/-4);
RF Maximum Power
+5dBm
** Specifications are subject to change and improvement without notice.
Troubleshooting
Symptom
Cause of Failure
1.
The Switch not working
The Switch is not
and LED off
plugged into the
electrical outlet
properly
2.
The Switch break down
The Switch LED
1.Check if the load
illuminating, but cannot
plugged into the Switch
1
Recommendation
1.
Check power connections
2. Don't open up the Switch and send it
for repair.
1. Set the ON/OFF switch of the load
attached to ON

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PAN16 and is the answer not in the manual?

Questions and answers

Summary of Contents for Philio PAN16

  • Page 1 PAN16-1; PAN16-2; PAN16-3 Maximum Load (Ampere) 10A (Resistive load) Introduction PAN16-4 (Switzerland) This plug-in ON/OFF switch PAN16 is a security enabled wireless switch, based on Germany type: PAN16-1 Socket Type: Z-Wave Plus technology. Z-Wave Plus enabled devices displaying the Z-Wave...
  • Page 2: Danger Of Electrocution

    13A (Resistive Danger of electrocution! load) For Instruction to http:// www.philio-tech.com All works on the device may be performed only by a qualified and licensed electrician. Observe national regulations. Any works introducing changes into the configuration must be always performed with disconnected voltage.
  • Page 3: Led Indication

    Node ID and just plug the switch into a wall outlet. Association The PAN16 is an always listening Z-Wave device, so associations may Note: Auto inclusion timeout is 2 minute during which the node information of explorer be added or removed by a controller frame will be emitted once several seconds.
  • Page 4: Choosing A Suitable Location

    By pressing On/Off button, it will stop flashing temporarily. report its On/Off state to the node asked. Learning When PAN16 is in learning mode, LED flashes on and off alternately and repeatedly at 0.5 second intervals. Basic Get Command: [Command Class Basic, Basic Get]...
  • Page 5 [Command Class Meter, , , , Meter Report, , , , Rate Type = 0x01, , , , Meter Type = 0x01, , , , When PAN16 detects the current is more than 14.5A, it will send Alarm Report to Precision = 2,...
  • Page 6 can use Meter Reset Command to clear it. AC load current = (Meter Value 1*256) +(Meter Value 2)= 2.89 (A) 2-2-6 load power factor (PF) Meter Reset Command: [Command Class Meter, Meter Reset] When receiving Meter Get Command, it will report Meter Report Command to the node.
  • Page 7 Meter Report Period: 3-8 Auto off timer:The default setting is 0. If the setting is configured for 1hour (set value =720), PAN16 will report its instant Whenever PAN16 switches to on, the auto off timer begin to count down. After the power consumption to Group1 node every 1 hour.
  • Page 8 1450 for 14.5A. (1450 * 0.01A = 14.5A) 3-13 Watt differential mode:The default setting is 1 (= 5%). Whenever Watt value of PAN16 changes over 5% of last reading value, it will send Disposal Meter report to the group 1 nodes. However if Watt differential mode as 0, the This marking indicates that this product should not be disposed with unsolicited report will be disabled.