Download Print this page

Philio PAN45 Manual

Smart energy plug
Hide thumbs Also See for PAN45:

Advertisement

Quick Links

Smart Energy Plug
This plug-in ON/OFF switch PAN45 is a devices displaying the Z-Wave Plus
also be used security enabled wireless switch, based on Z-Wave Plus technology. Z-
Wave Plus
TM
enabled with it regardless of the manufacturer, and can also be used in
other manufacturer's Z-Wave
TM
enabled networks. Remote On/Off control of the con-
nected load is possible with another manufacturer's wireless Controller. Each switch is
designed to act as a repeater. Repeaters will re-transmit the RF signal to ensure that the
signal is received by its intended destination by routing the signal around obstacles and
radio dead spots. Because PAN45 supports Security Command Class, it can learn with
Secured controller. Its functionality and supported command classes are identical when
included as a secure and non-secure device. It also have Zigbee as a repeater.
This plug-in ON/OFF switch is able to detect instance wattage (3000W/230Vac/13A)
and overload current (14.5A with resistive load) of connected lights or appliances. When
detecting overload state, the Switch will be disabled and it's On/Off button will be lock-
out of which LED will flash quickly. However, unplug and reconnect the switch will re-
set its overload condition to normal status.
PAN45
Specification
Operating Voltage
Maximum Load (Ampere)
Range
Operating Temperature
Location
Frequency Range
RF Maximum Power
TM
logo can
** Specifications are subject to change and improvement without notice.
Troubleshooting
Symptom
The Switch not working
and LED off
The Switch LED illumi-
nating, but cannot control
the Switch of the load at-
tached
The Switch LED illumi-
nating, but the Detector
cannot control the Switch
LED keep flashing, but
cannot control
100V-240V~ 50Hz-60Hz
13A (Resistive load)
Minimum 40 m in door 100m outdoor line of sight
0°C ~ 40°C, 85%RH max
In door use
Z-Wave: 868.40MHz & 869.85MHz (EU)
Zigbee: 2405-2480MHz
+10dBm (Peak), -10dBm (Average) for Z-wave
+10dBm for Zigbee
Cause of Failure
1.The Switch is not plugged into
1. Check power connections
the electrical outlet properly
2. Don't open up the Switch
2.The Switch break down
and send it for repair.
1. Set the ON/OFF switch of
1.Check if the load plugged into
the load attached to ON
the Switch has its own ON/OFF
2. Unprotected the switch or
switch
follow the instruction of pro-
2. The switch is protected
tection.
1. Not carry out association
1. Carry out association
2. Same frequency interference
2. Wait for a while to retry
Remove the load attached or
Overload occurs
check max. load cannot ex-
ceed 13A (Resistive load)
Recommendation

Advertisement

loading
Need help?

Need help?

Do you have a question about the PAN45 and is the answer not in the manual?

Questions and answers

Summary of Contents for Philio PAN45

  • Page 1 1. Set the ON/OFF switch of radio dead spots. Because PAN45 supports Security Command Class, it can learn with The Switch LED illumi- 1.Check if the load plugged into the load attached to ON Secured controller.
  • Page 2: Product Overview

    Product overview For Instruction to http://www.philio-tech.com Warning: DANGER 1.Plug out to disconnect from power supply; Do not plug in line. Danger of electrocution! 2. Do not exceed the max rating. All works on the device may be performed only by a qualified and licensed elec- trician.
  • Page 3 Z-Wave and Zigbee functions. Please refer to the QR code. The QR Code can be instructions for your Z-Wave or Zigbee Certificated Primary Controller to ac- found on PAN45 or in the box. cess the Setup function, and to include/exclude/reset devices. DSK:18112-24021-58001-62259- 57092- 27453-08187-47408 Warning: 2.PAN45 is supported with Smart-...
  • Page 4 Off button three times within 2 sec- Reset 1.Pressing On/Off button six times Use this procedure only in onds will cause the PAN45 to send its within 3 seconds and hold at least the event that the primary NIF. 5s at the sixth time to reset device.
  • Page 5: Installation

    The LED will turn OFF and the load plugged into the Switch will also Learning When PAN45 is in learning mode, LED flashes on and off alternately and turn OFF. repeatedly at 0.5 second intervals. Programming Zigbee 1. Basic Command Class / Binary Switch Command Class...
  • Page 6 Switch turns on. When PAN45 detects the current is more than 14.5A, it will send Alarm Report to Group 1 node. [Command Class Basic, Basic Set, Value = 0(0x00)]: the load attached to the Switch turns off.
  • Page 7 Type = 0x01 , Precision = 1 , Scale = 0x04 , Size = 2 , Meter the node. Meter Get Command: Value(V)] [Command Class Meter, Meter Get, Scale = 0x00 KWh)] Example: Meter Report Command: Scale = 0x04 (V) [Command Class Meter,Meter Report,Rate Type = 0x01 ,...
  • Page 8 Report Period Report 3-2 KWH Meter Report Period: 0x7FFF 1~32767: If the setting is configured for 1hour (set value =6), PAN45 will report its Ac- 10min~ 227days cumulated Power Consumption (KWh) to Group1 node every 1 hour. The Threshold of 1300*0.01A...
  • Page 9 3-8 Watt differential mode:The default setting is 1 (= 5%). Binary Switch Highest granted Security Class Whenever Watt value of PAN45 changes over 5% of last reading value, it will Configuration Highest granted Security Class send Meter report to the group 1 nodes. However, if Watt differential mode as...