This plug-in ON/OFF switch PAN38 is a security enabled wireless switch, based on Z-
Wave Plus technology. Z-Wave Plus
logo can also be used with it regardless of the manufacturer, and can also be used in
TM
other manufacturer's Z-Wave
enabled networks. Remote On/Off control of the con-
nected load is possible with another manufacturer's wireless Controller. Each switch is
designed to act as a repeater. Repeaters will re-transmit the RF signal to ensure that the
signal is received by its intended destination by routing the signal around obstacles and
radio dead spots. Because PAN38 supports Security Command Class, it can learn with
Secured controller. Its functionality and supported command classes are identical when
included as a secure and non-secure device.
This plug-in ON/OFF switch is able to detect instance wattage (3000W/230VAC/13A)
and overload current (14.5A with resistive load) of connected lights or appliances. When
detecting overload state, the Switch will be disabled and it's On/Off button will be lock-
out of which LED will flash quickly. However, unplug and reconnect the switch will re-
set its overload condition to normal status.
TM
enabled devices displaying the Z-Wave Plus
Specification
Operating Voltage
Maximum Load (Ampere)
Maximum Load (Ampere)
Socket Type:
Range
Operating Temperature
Frequency Range
RF Maximum Power
** Specifications are subject to change and improvement without notice.
Troubleshooting
TM
Symptom
1.The Switch is not plugged into
The Switch not working
the electrical outlet properly
and LED off
2.The Switch break down
The Switch LED illumi-
1.Check if the load plugged into
nating, but cannot control
the Switch has its own ON/OFF
the Switch of the load at-
switch
tached
2. The switch is protected
The Switch LED illumi-
1. Not carry out association
nating, but the Detector
2. Same frequency interference
cannot control the Switch
LED keep flashing, but
Overload occurs
cannot control
100V-240V~ 50Hz-60Hz
13A (Resistive load) PAN38-1; PAN38-2; PAN38-3
10A (Resistive load) PAN38-4 (Switzerland)
Germany type: PAN38-1
France type: PAN38-2
UK type: PAN38-3
Switzerland type: PAN38-4
Minimum 40 m in door 100m outdoor line of sight
0°C ~ 40°C
868.40MHz & 869.85MHz/ EU (PAN38-1/-2/-3/-4);
+10dBm (Peak), -10dBm (Average)
Cause of Failure
Recommendation
1. Check power connections
2. Don't open up the Switch
and send it for repair.
1. Set the ON/OFF switch of
the load attached to ON
2. Unprotected the switch or
follow the instruction of pro-
tection.
1. Carry out association
2. Wait for a while to re-try
Remove the load attached or
check max. load cannot ex-
ceed 13A (Resistive load)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PAN38 and is the answer not in the manual?

Questions and answers

Summary of Contents for Philio PAN38

  • Page 1 RF Maximum Power +10dBm (Peak), -10dBm (Average) ** Specifications are subject to change and improvement without notice. This plug-in ON/OFF switch PAN38 is a security enabled wireless switch, based on Z- Troubleshooting Wave Plus technology. Z-Wave Plus enabled devices displaying the Z-Wave Plus...
  • Page 2 Warning: For Instruction to http://www.philio-tech.com 1.Plug out to disconnect from power supply; Do not plug in line. 2. Do not exceed the max rating. Warnung: 1.Trennen Sie das Gerät von der Stromzuführung. Verwenden Sie das Gerät nicht mit einem DIP Schalter.
  • Page 3: Auto Inclusion

    Z-Wave Certificated Primary Controller to ac- auto inclusion) cess the Setup function, and to Add/Remove/Associate devices Association The PAN38 is an always listen- ing Z-Wave device, so associa- Function Description Annotation tions may be added or removed...
  • Page 4: Led Indication

    On/Off button, it will stop flashing temporarily. 1-1 BASIC_GET / BINARY_SWITCH_GET Learning When PAN38 is in learning mode, LED flashes on and off alternately and Upon receipt of the following commands from a Z-Wave Controller, the repeatedly at 0.5 second intervals.
  • Page 5 [Command Class Switch Binary, Switch Binary Set, Value = 1~99, (255)0xFF]: the load attached to the Switch turns on. When PAN38 detects the current is more than 14.5A, it will send Alarm Report to Group 1 node. [Command Class Switch Binary, Switch Binary Set, Value = 0(0x00)]: the load attached to the Switch turns off.
  • Page 6 Accumulated power consumption (KWh) = (Meter Value 2*65536) + (Meter Value 3*256) + (Meter Value 4) = 800.35 (KWh) Meter Get Command: [Command Class Meter, Meter Get, Scale 2-2-3 Clearing accumulated power consumption =0x02(W)] Whenever re-start counting the accumulated power consumption is needed, you Meter Report Command: can use Meter Reset Command to clear it.
  • Page 7 3. Z-Wave’s Configuration report mode 1:Enable Configuration Size Function Value Unit Default Description Parameter (Byte) 3-1 Watt Meter Report Period: Watt Meter 0x0000 0: Disable Watt If the setting is configured for 1hour (set value =720), PAN38 will report its...
  • Page 8 3-2 KWH Meter Report Period: 3-7-3 One Flash mode : When the state of switch changes, LED will be on If the setting is configured for 1hour (set value =6), PAN38 will report its Ac- only one second, then LED keeps off.
  • Page 9 Binary Switch Highest granted Security Class Configuration Highest granted Security Class Device Reset Locally Highest granted Security Class France type PAN38-2 Firmware Update Meta Data Highest granted Security Class Indicator Highest granted Security Class Manufacturer Specific Highest granted Security Class...
  • Page 10 FCC Caution: Any changes or modifications not expressly approved by the party respon- Company of License Holder:Philio Technology Corporation sible for compliance could void the user's authority to operate this equipment. Address of License Holder : 8F., No.653-2, Zhongzheng Rd., Xinzhuang Dist., This transmitter must not be co-located or operating in conjunction with any other an- New Taipei City 24257, Taiwan(R.O.C)