Smart energy plug PAN38
This plug-in ON/OFF switch PAN38 is a security enabled wireless switch, based on Z-
Wave Plus technology. Z-Wave Plus
logo can also be used with it regardless of the manufacturer, and can also be used in
TM
other manufacturer's Z-Wave
enabled networks. Remote On/Off control of the con-
nected load is possible with another manufacturer's wireless Controller. Each switch is
designed to act as a repeater. Repeaters will re-transmit the RF signal to ensure that the
signal is received by its intended destination by routing the signal around obstacles and
radio dead spots. Because PAN38 supports Security Command Class, it can learn with
Secured controller. Its functionality and supported command classes are identical when
included as a secure and non-secure device.
This plug-in ON/OFF switch is able to detect instance wattage (3000W/230VAC/13A)
and overload current (14.5A with resistive load) of connected lights or appliances. When
detecting overload state, the Switch will be disabled and it's On/Off button will be lock-
out of which LED will flash quickly. However, unplug and reconnect the switch will re-
set its overload condition to normal status.
TM
enabled devices displaying the Z-Wave Plus
Specification
Operating Voltage
Maximum Load (Ampere)
Maximum Load (Ampere)
Socket Type:
Range
Operating Temperature
Frequency Range
RF Maximum Power
** Specifications are subject to change and improvement without notice.
Troubleshooting
TM
Symptom
1.The Switch is not plugged into
The Switch not working
the electrical outlet properly
and LED off
2.The Switch break down
The Switch LED illumi-
1.Check if the load plugged into
nating, but cannot control
the Switch has its own ON/OFF
the Switch of the load at-
switch
tached
2. The switch is protected
The Switch LED illumi-
1. Not carry out association
nating, but the Detector
2. Same frequency interference
cannot control the Switch
LED keep flashing, but
Overload occurs
cannot control
100V-240V~ 50Hz-60Hz
13A (Resistive load) PAN38-1; PAN38-2; PAN38-3
10A (Resistive load) PAN38-4 (Switzerland)
Germany type: PAN38-1
France type: PAN38-2
UK type: PAN38-3
Switzerland type: PAN38-4
Minimum 40 m in door 100m outdoor line of sight
0°C ~ 40°C
868.40MHz & 869.85MHz/ EU (PAN38-1/-2/-3/-4);
+10dBm (Peak), -10dBm (Average)
Cause of Failure
Recommendation
1. Check power connections
2. Don't open up the Switch
and send it for repair.
1. Set the ON/OFF switch of
the load attached to ON
2. Unprotected the switch or
follow the instruction of pro-
tection.
1. Carry out association
2. Wait for a while to re-try
Remove the load attached or
check max. load cannot ex-
ceed 13A (Resistive load)
Need help?
Do you have a question about the PAN38 and is the answer not in the manual?
Questions and answers