ABOUT THESE OPERATING INSTRUCTIONS ..3 INTENDED USE ............. 5 BASIC SAFETY INFORMATION ......6 GENERAL INFORMATION ........9 DESCRIPTION ............10 TECHNICAL DATA ..........15 INSTALLATION AND COMMISSIONING ..... 26 MAINTENANCE ............ 41 ACCESSORIES ............ 43 10. PACKAGING, TRANSPORT ........44 11.
ABOUT THESE OPERATING INSTRUCTIONS The Operating Instructions describe the entire life cycle of the device. Please keep the Operating Instructions in a safe place, accessible to all users and any new owners. The Operating Instructions contain important safety information. Failure to comply with these instructions can lead to hazardous situations.
Page 4
WARNING Warns against a potentially dangerous situation. ▶ Failure to observe this warning can result in serious injury or even death. CAUTION Warns against a possible risk. ▶ Failure to observe this warning can result in sub- stantial or minor injuries. NOTE Warns against material damage.
INTENDED USE Use of the device that does not comply with the instructions could present risks to people, nearby installations and the environment. The flowmeter type 8030 and the flow transmitter type SE30 combined with a sensor-fitting are intended exclusively to measure flow rate in liquids. ▶...
BASIC SAFETY INFORMATION This safety information does not take into account any contingencies or occurrences that may arise during installation, use and maintenance of the device. The operating company is responsible for the respect of the local safety regulations including for the staff safety. Danger due to high pressure in the installation Danger due to electrical voltage Danger due to high temperatures of the fluid...
Page 7
Various dangerous situations To avoid injury: ▶ Do not use the device in an environment incompat- ible with the materials it is made of. ▶ Do not use fluid that is incompatible with the mate- rials the device is made of. ▶...
Page 8
NOTE The device may be damaged by the fluid in contact with ▶ Systematically check the chemical compatibility of the component materials of the device and the fluids likely to come into contact with them (for example: alcohols, strong or concentrated acids, aldehydes, alkaline compounds, esters, aliphatic compounds, ketones, halogenated aromatics or hydrocarbons, oxidants and chlorinated agents).
You may also contact your local Bürkert sales office. The addresses of our international sales offices are available on the internet at: country.burkert.com Warranty conditions The condition governing the legal warranty is the con- forming use of the device in observance of the operating conditions specified in these Operating Instructions.
DESCRIPTION Construction of the flow transmitter SE30 The SE30 is a flow transmitter and has: • 1 transistor output NPN • 1 NPN transistor output and 1 PNP transistor output English...
Page 11
The conversion coefficient (K-factor) expressed in pulses per litre is given in the Operating Instructions of the sensor-fitting type S030 used, available at: country.burkert.com. B: Flow transmitter SE30 (see page 10). English...
Page 12
The conversion coefficient (K-factor) expressed in pulses per litre is given in the Operating Instructions of the sensor-fitting type S077 used, available at: country.burkert.com B: Flow transmitter SE30 (see page 10). English...
Page 13
Type label FLOW : SE30 / 8030 HALL 12-36 V DC OPEN COLLECTOR PNP/NPN S/N:59037 00423913 W45LG 1. Type of sensor 2. Measured quantity 3. Type of the device 4. Supply voltage 5. Output data 6. Conformity marking 7. Manufacturing code 8.
Page 14
Symbols on the device Symbol Description Direct current Alternating current Earth terminal Protective conductor terminal English...
TECHNICAL DATA Technical data of an SE30 The technical data of the flow transmitter SE30 may be restricted by the sensor-fitting used. ▶ Refer to the Operating Instructions of the sensor-fitting used. Conditions of use of an SE30 Ambient temperature –15 °C...+60 °C (operating) Air humidity...
Page 16
Type label Polyester Dimensions of an SE30 Please refer to the technical data sheets of the device, available at: country.burkert.com Electrical data of an SE30 Supply voltage • Hall version • 12...36 V DC, filtered and regulated. The device must be con-...
Page 17
Current consumption • Hall version • 30 mA max. • Hall Low Power • 0.8 mA max. version Protection against polarity reversal Transistor output Pulse output, NPN and PNP, (Hall version) open collector, max. 100 mA, frequency up to 300 Hz, duty cycle 1/2 ± 10 % NPN output: 0.2...36 V DC PNP output: supply voltage Transistor output...
Page 18
Technical data of an 8030 Conditions of use of an 8030 → See "Conditions of use of an SE30", page 15. Standards and directives of an 8030 The device complies with the relevant EU harmonisation legislation. In addition, the device also complies with the requirements of the laws of the United Kingdom.
Page 19
Paragraph 1.c.ii or PSxDN ≤ 5000 Dimensions of an 8030 → Please refer to the technical data sheets of the device, available at: country.burkert.com Materials of an 8030 Wetted parts Material • Sensor-fitting S030 • Refer to the Operating Instructions of the sensor- fitting used.
Page 20
Fluid data of an 8030 DN6 to DN65. The appro- Pipe diameter priate diameter is determined using the flow rate / DN / fluid velocity graphs. Depends on the material of Fluid pressure the fitting used and on the fluid temperature: refer to the Operating Instructions of the sensor-fitting used.
Page 21
Flow rate measurement • Measurement range • 0.3...10 m/s • Measurement deviation - ±1 % of the measured - with K-factor value * (at the value of the determined with Teach-In flow rate) a Teach-In pro- cedure - ±2.5 % of the measured - with standard value * K-factor •...
Page 22
Technical data of an SE30 with sensor-fitting S077 Conditions of use of an SE30+S077 Ambient temperature 0...+60 °C (operating) Air humidity < 80 %, non condensated Protection rating IP65, female connector wired, plugged and tightened Standards and directives of an SE30+S077 The device complies with the relevant EU harmonisation legislation.
Page 23
Fluid group 2, Article 4, DN ≤ 32 Paragraph 1.c.i or PSxDN ≤ 1000 Fluid group 1, Article 4, DN ≤ 25 Paragraph 1.c.ii or PSxDN ≤ 2000 DN ≤ 200 Fluid group 2, Article 4, or PS ≤ 10 Paragraph 1.c.ii or PSxDN ≤ 5000 Dimensions of an SE30+S077 → Please refer to the technical data sheets of the SE30+S077, available at: country.burkert.com English...
Page 24
Materials of an SE30+S077 Wetted parts Material • Sensor-fitting S077 • Refer to the Operating Instructions of the sensor-fitting used. → See also "Materials of an SE30", page 16. Fluid data of an SE30+S077 Type and data of the fluid Refer to the Operating Instructions of the sensor- fitting used.
Page 25
Flow rate measurement • Measurement range - viscosity > 5 mPa.s - 2...1200 I/min - viscosity < 5 mPa.s - 3...616 I/min • Measurement deviation - ±0.5 % of the - if "specific" K-factor measured value is used (marked on the name plate of the device) - ±1 % of the - if "standard"...
INSTALLATION AND COMMISSIONING Safety instructions DANGER Risk of injury due to electrical voltage ▶ If a 12...36 V DC powered version is installed either in a wet environment or outdoors, all the electrical voltages must be of max. 35 V DC. ▶ Shut down and isolate the electrical power source before carrying out work on the system.
Page 27
DANGER Risk of injury due to the nature of the fluid ▶ Respect the prevailing regulations on accident prevention and safety relating to the use of danger- ous fluids. WARNING Risk of injury due to unintentional switch on of power supply or uncontrolled restarting of the installation ▶...
Page 28
WARNING Risk of injury due to non-conforming commissioning. Non-conforming commissioning may lead to injuries and damage the device and its surroundings. ▶ Before commissioning, make sure that the staff in charge have read and fully understood the contents of the Operating Instructions. ▶...
Page 29
Fluid Installation of the 8030 The 8030 is inserted into an S030 sensor-fitting mounted on the pipe. The SE30 is assembled on the S030 sensor-fitting by a quarter-turn rotation system. Installing the S030 sensor-fitting on the pipe → Select an S030 sensor-fitting suitable for the fluid in the pipes.
Page 30
Example : - Specification: for a nominal flow rate of 10 m the ideal flow velocity is between 2 and 3 m/s. - Solution: intersection between flow rate and flow velocity in the graph gives the appropriate pipe di- ameter, DN40 (or DN50 for the asterisked fittings). * For the fittings: •...
Page 32
Assembling the SE30 with the S030 sensor-fitting 1. Install the SE30 in the S030 sensor-fitting. 2. Turn the SE30 by a quarter turn. 3. Tighten the lateral screw(s) to lock SE30 in place on the sensor-fitting (tightening torque max. 1 Nm, i.e.
Page 33
Installing the S077 sensor-fitting on the pipe → Select an S077 sensor-fitting adapted to the vis- cosity of the fluid in the pipe. To select a sensor-fitting, refer to the technical data sheet for the relevant sensor-fitting. CAUTION Risk of damage when installing the sensor-fitting. ▶...
Page 34
Correct Incorrect Fig. 3: The spindles of the oval gears must be horizontal Assembling the SE30 with the S077 sensor-fitting → Insert the SE30 in the S077 sensor-fitting. → Turn the SE30 by a SE30 quarter turn. → Tighten the lateral screws to lock the SE30 in place on the S077 sensor-fitting S077 (tightening torque max.
Page 35
Finalising the installation of the SE30 with S077 sensor-fitting → Wire the device and switch it on (see "Wiring", page 35). Wiring DANGER Risk of injury due to electrical discharge ▶ If a 12...36 V DC powered version is installed either in a wet environment or outdoors, all the electrical voltages must be of max.
Page 36
▶ Use a high quality electrical power supply (filtered and regulated). Electrical connection is made via a male fixed connector by a female connector type 2518 or type 2509. Specifications of the connection cables Tab. 1: Specifications of the cables and wires for the female connector type 2518 with article number 00572264 (supplied), or the female connector type 2509 with article number 00162673 (not supplied) Specification of the cables and the Recommended conductors (not supplied) value...
Page 37
Assembling the female connector → Unscrew the pressure screw [1] and remove the pressure ring [2] and the seal [3]. → Remove contact holder [5] from the cover [4]. → Insert the cable into pressure screw [1], through the pressure ring [2], through the seal [3] and finally through the cover [4]. →...
Page 38
→ Place the seal [6] between the connector and the fixed con- nector on the device and then plug the type 2518 connector into the fixed connector. → Insert and tighten the central screw [7] (0.5...0.6 Nm) to ensure tightness and correct electrical contact. Fig. 5: Assembling the female connector type 2518 (supplied)
Page 39
Pulse input on external instrument Terminal block of the 2518 0 V DC 12-36 V DC Power supply Fig. 7: NPN wiring of the Hall version Pulse input on external instrument 0 V DC 12-36 V DC Power supply Fig. 8: PNP wiring of the Hall version English...
Page 40
1. V+ (12...36 V DC) 2. NPN transistor output 3. 0 V DC 4. Not connected Fig. 9: Pin assignment of the male fixed connector, Hall Low Power version Terminal block of the 2518 IN = pulse input on remote transmitter Remote transmitter Fig. 10: NPN wiring of the Hall Low Power version English...
MAINTENANCE Safety instructions DANGER Risk of injury due to electrical voltage. ▶ If a 12...36 V DC powered version is installed either in a wet environment or outdoors, all the electrical voltages must be of max. 35 V DC. ▶ Disconnect the electrical power for all the conductors and isolate it before carrying out work on the system.
Page 42
WARNING Risk of injury due to non-conforming maintenance. ▶ Maintenance must only be carried out by qualified and skilled staff with the appropriate tools. ▶ Ensure that the restart of the installation is controlled after any interventions. Cleaning the device →...
ACCESSORIES CAUTION Risk of injury and/or damage caused by the use of unsuitable parts. Incorrect accessories and unsuitable spare parts may cause injuries and damage the device and the sur- rounding area. ▶ Use only original accessories and original spare parts from Bürkert.
10. PACKAGING, TRANSPORT NOTE Damage due to transport Transport may damage an insufficiently protected device. ▶ Transport the device in shock-resistant packaging and away from humidity and dirt. ▶ Do not expose the device to temperatures that may exceed the admissible storage temperature range. ▶...
12. DISPOSAL Environmentally friendly disposal ▶ Follow national regulations regarding disposal and the environment. ▶ Collect electrical and electronic devices separately and dispose of them as spe- cial waste. Further information country.burkert.com. English...
Need help?
Do you have a question about the 8030-SE30 Series and is the answer not in the manual?
Questions and answers