Table of Contents

1. Technical specifications ................................................................................................................... 2
2. Pack contents ............................................................................................................................... 3
3. Description .................................................................................................................................. 3
3.1. Bluetooth® and Wifi control ......... .......................................................................................... 4
3.2. iOs / Android applications ...................................................................................................... 4
3.3. Automatic treatment - RedOx regulation ..................................................................................... 4
4.1. Wall mounting .............. ...................................................................................................... 5
4.2. Hydraulic connection ............................................................................................................ 5
4.3. Connecting the sensor and flow detector ..................................................................................... 8
4.4. Connection to electricity ............................................................................................ ............ 8
5. Operation .................................................................................................................................... 9
5.1. Control interface ................................................................................................................. 9
5.2. Configuration ..................................................................................................................... 9
6. Appliance operation .......... ............................................................................................................ 12
6.1. Data timer and injection not active: ......................................................................................... 12
6.2. Selecting of set-point value ................................................................................................... 12
6.3. Measured value display ............................................................................................ ............ 13
7. Reset to zero ............................................................................................................................... 13
8. Sensor maintenance ...................................................................................................................... 13
A. Declaration of conformity ............................................................................................................. 15
Read these instructions carefully before installing, commissioning and using this product.
MPNT0466 1.1EN (30/06/2023)
Oxeo POD VP
& Oxeo VP

Advertisement

Table of Contents
loading

Summary of Contents for ccei Oxeo POD VP

  • Page 1: Table Of Contents

    3.1. Bluetooth® and Wifi control ....................4 3.2. iOs / Android applications ...................... 4 3.3. Automatic treatment - RedOx regulation ..................4 4. Installing the Oxeo POD VP & Oxeo VP ..................... 5 4.1. Wall mounting ........................5 4.2. Hydraulic connection ......................5 4.3.
  • Page 2: Technical Specifications

    Oxeo POD VP & Oxeo VP 1.1EN OPERATING INSTRUCTIONS 1. Technical specifications Dimensions 260 x 180 x 80 Power supply voltage 230 V AC 50Hz Power consumption Weight 700 g (Pump only) Protection rating IP-54 Redox regulation Measurement using a combined electrode - +/- 5mV...
  • Page 3: Pack Contents

    • User friendly interface: 1 selection button + 5 indicator lights • User friendly smartphone app • Wifi and Bluetooth connection – Easier installation using the ZeliaPod measuring and injection chamber (if Oxeo POD VP) • Compatible with the Vigipool connected environment...
  • Page 4: Bluetooth® And Wifi Control

    The Oxeo POD VP & Oxeo VP control box has an embedded Bluetooth® and Wifi transmitter used to control your appliance from a smartphone or tablet. To be able to control the Oxeo POD VP & Oxeo VP, you need an iOs (Apple®) or Android smart- phone or tablet running Bluetooth®...
  • Page 5: Installing The Oxeo Pod Vp & Oxeo Vp

    The Oxeo VP model is shipped with 3 pipe saddles to install the accessories required to correct operation. To make installation easier, the Oxeo POD VP model is shipped with the ZeliaPod measuring and injection chamber. This measuring chamber makes it possible to limit the number of drill holes in the piping and to centralise data.
  • Page 6 Oxeo POD VP & Oxeo VP 1.1EN OPERATING INSTRUCTIONS 4.2.2.1. Sensor installation - Oxeo VP model The sensor is installed on the outlet pipe using a pipe saddle into which the sensor holder is screwed. 4.2.3. ZeliaPod hydraulic installation - POD VP model only ZeliaPod installs on a diameter 50mm pipe using the supplied union fittings.
  • Page 7 Oxeo POD VP & Oxeo VP 1.1EN OPERATING INSTRUCTIONS A. Ground rod B. Sensor housing C. Sensor housing (not used) D. Flow detector E. Injector housing F. Injector housing (not used) Use the supplied roll of Teflon tape when assembling the sensor holder and the supplied flat seal for the injector.
  • Page 8: Connecting The Sensor And Flow Detector

    Oxeo POD VP & Oxeo VP 1.1EN OPERATING INSTRUCTIONS 4.3. Connecting the sensor and flow detector 1. Power supply cable 2. RedOx sensor 3. Flow detector 4. Dosing pump 4.4. Connection to electricity Installation of this project involves a hazard of electric shocks. We strongly recommend you contract a professional installer.
  • Page 9: Operation

    5. Operation Oxeo POD VP & Oxeo VP can be configured using the pump interface or from the smartphone app available for iOS and Android. We encourage you to use the app which provides access to additional parameters, in particular for calibration.
  • Page 10 Oxeo POD VP & Oxeo VP 1.1EN OPERATING INSTRUCTIONS 5.2.2. Selecting the "central" Vigipool device • Please refer to the attached "Vigipool Universe" leaflet for more information. Once the control mode has been selected, the multi-colour LED (C) flashes white. This corresponds to the chosen device that will operate the Vigipool "central"...
  • Page 11 Oxeo POD VP & Oxeo VP 1.1EN OPERATING INSTRUCTIONS 5.2.4. Sensor calibration The filtering must be turned off to calibrate the sensor. 1. Immerse the Redox sensor in the 650mV calibration solution 2. Keep the selection button (A) pressed for 3 seconds 3.
  • Page 12: Appliance Operation

    • Incremented in 1 L steps 6. Appliance operation Oxeo POD VP & Oxeo VP does not take any measurements: • during the first 2 minutes after power up (time for the value to be set), • if the flow rate is not detected by the device (to ensure that measurements are only taken when the filtration is running and to guarantee the correct values of the pool water and not of the stagnant water in the pipe).
  • Page 13: Measured Value Display

    7. Reset to zero It is possible that a factory reset may be required to set the OXEO POD VP & OXEO VP back to the original factory settings. To do this, please: 1. Turn off the device ( on/off switch on the box side) and wait for about 10 seconds, 2.
  • Page 14 Oxeo POD VP & Oxeo VP 1.1EN OPERATING INSTRUCTIONS An incorrectly winterised sensor will have a slower response time and make it harder to cali- brate. Sensor regeneration: At the end of winterisation, we recommend immersing the sensor in a 50% PH4, 50% KCl 3 mol/l solution for 12h Calibration: Each sensor is characterised by its drift and slope.
  • Page 15: Declaration Of Conformity

    1.1EN OPERATING INSTRUCTIONS A. Declaration of conformity Bleu Electrique SAS (FR47403521693) declares that the Oxeo POD VP & Oxeo VP product meets the safe- ty and electromagnetic compatibility requirements of European directives 2014/35/EU and 2014/30/EU. Emmanuel Baret Marseille, on 30/06/2023 Distributor's stamp Date of sale: .