ccei Oxeo VP Technical Manual

ccei Oxeo VP Technical Manual

Automatic and connected chlorine regulator
Hide thumbs Also See for Oxeo VP:

Advertisement

Quick Links

Table des matières
1. Important Safety Instructions ....................................................................................................... 2
2. Package Content .......................................................................................................................... 2
3. Description .................................................................................................................................. 3
4. Technical Specifications .............................................................................................................. 3
5. Installation ................................................................................................................................... 4
5.1. Wall Mounting ................................................................................................................. 4
5.2. Hydraulic Connection ....................................................................................................... 4
5.3. Accessories Positioning (Zelia POD, for 1.5" Piping) ....................................................... 5
5.4. Accessories Positioning (for 2" Piping) ............................................................................ 7
5.5. RedOx Sensor, Flow Switch and Tube Connection ........................................................... 8
5.6. Electrical Wiring .............................................................................................................. 8
6. Smartphone Application .............................................................................................................. 9
6.1. App Download ................................................................................................................. 9
6.2. Connect your Device to Vigipool ..................................................................................... 9
7. Setting the Oxeo ........................................................................................................................ 10
7.1. Control Interface ............................................................................................................. 10
7.2. Getting Started with the Oxeo ........................................................................................ 10
7.3. Additional Parameters to be set via the Smartphone App ................................................ 12
8. Operating the Oxeo ................................................................................................................... 12
8.1. Information Delay and Non-Active Injection .................................................................. 12
8.2. Setpoint Selection ........................................................................................................... 13
8.3. Measured Value Display ................................................................................................. 13
8.4. Product Factory Reset ..................................................................................................... 13
9. Sensor Maintenance ................................................................................................................... 14
A. Technical Support / Declaration of Conformity .................................................................... 15
CONT0047 v1.0EN (10/31/2022)
Technical Manual
Oxeo VP &
Oxeo LT VP
Automatic and Connec-
ted Chlorine Regulator
PF10J055 - PF10J056

Advertisement

Table of Contents
loading

Summary of Contents for ccei Oxeo VP

  • Page 1: Table Of Contents

    Technical Manual Oxeo VP & Oxeo LT VP Automatic and Connec- ted Chlorine Regulator PF10J055 - PF10J056 Table des matières 1. Important Safety Instructions ....................... 2 2. Package Content .......................... 2 3. Description ..........................3 4. Technical Specifications ......................3 5.
  • Page 2: Important Safety Instructions

    MUST READ AND UNDERSTAND THE WARNINGS AND INSTRUCTIONS IN THIS MANUAL BEFORE USING THIS PRODUCT. This manual contains instructions for installing and using the Oxeo VP & Oxeo LT VP. Contact CCEI for any questions about the equipment. To the installer: This manual contains important safety information on the instal- lation and use of this product.
  • Page 3: Description

    • Easy installation thanks to the Zelia measuring and injection chamber • Compatible with the Vigipool-connected universe Oxeo VP & Oxeo LT VP measure the RedOx potential and introduce an oxidizing product into the pool water as long as the RedOx potential is below the set threshold.
  • Page 4: Installation

    Technical Manual Oxeo VP & Oxeo LT VP v1.0EN 5. Installation Always mount the controller in a safe and non-floodable area. Never bury the po- wer cable. The controller must not be installed directly outside, it must be protected from rain, cleaning or watering jets and UVs (sunlight).
  • Page 5: Accessories Positioning (Zelia Pod, For 1.5" Piping)

    Technical Manual Oxeo VP & Oxeo LT VP v1.0EN When installing and using the Zelia Pod, make sure that it is loaded relative to the water level of the pool, so that it is constantly filled with water and free of air. If air is present in the measurement chamber, the sensor readings may be distorted.
  • Page 6 Technical Manual Oxeo VP & Oxeo LT VP v1.0EN • D: Flow sensor (when installing, make sure that the arrow on the flow sensor points in the same direction as the flow direction) • E: Housing for injection (not used) •...
  • Page 7: Accessories Positioning (For 2" Piping)

    Technical Manual Oxeo VP & Oxeo LT VP v1.0EN 5.4. Accessories Positioning (for 2" Piping) Using the supplied support clamps, mount the RedOx probe, injector and flow sensor. Do not mount the disinfectant injection before the probe! (The sensor measurement would be distorted) Before installation, water must be drained from the piping.
  • Page 8: Redox Sensor, Flow Switch And Tube Connection

    Technical Manual Oxeo VP & Oxeo LT VP v1.0EN 5.5. RedOx Sensor, Flow Switch and Tube Connection A: Power supply cable (120 VAC) B: BNC socket for the RedOx sensor installation C: Flow switch connector D: Dosing pump For (D): the adapter on the left is for the aspiration of the disinfectant, and the one on the right is for the injection of the product into the pool water 5.6.
  • Page 9: Smartphone Application

    To connect this product to the Vigipool app: • Oxeo VP (PF10J055) only: If no other Vigipool product is connected and the Oxeo is the only one when the product is first powered on, wait for the LED to flash WHITE. Press the "Ox" button on the product to make the Oxeo the "Master"...
  • Page 10: Setting The Oxeo

    7. Setting the Oxeo The Oxeo VP and Oxeo LT VP can be set up via the interface of the box or via the smartphone app available on iOS® and Android®. We encourage you to use the app, which gives access to additional settings, especially for sensor calibration.
  • Page 11 Technical Manual Oxeo VP & Oxeo LT VP v1.0EN 7.2.3. Pump Priming To start the control circuit by rotating the peristaltic pump, it is necessary to hold down the selection button (A) for a long time (more than 10 seconds). After 10 seconds, the multi-color LED (C) will flash Turquoise and the pump will rotate regardless of the status of the flow sensor, for a maximum of 30 seconds, as long as the selector button is held down.
  • Page 12: Additional Parameters To Be Set Via The Smartphone App

    • Volume adjustable from 0 to 50 L • Increment of 1 L at a time 8. Operating the Oxeo Oxeo VP and Oxeo LT VP do not perform measurements: • during the first 2 minutes after powering up (to wait for the stabilization of the measurement), •...
  • Page 13: Setpoint Selection

    Technical Manual Oxeo VP & Oxeo LT VP v1.0EN • When the flow meter detects a flow rate, a 2-minute delay is built in before injection. The injection is instantly stopped when the flow rate returns to OFF. • No injection if ORP measurement is lower than 100 mV or greater than 900 mV (ORP measurement fault).
  • Page 14: Sensor Maintenance

    Technical Manual Oxeo VP & Oxeo LT VP v1.0EN • Press and hold the selection button (A); • Turn on the device while holding down the button; • Wait for the green indicator lights (B) to flash; • Release the button. All the parameters are reset to the factory settings.
  • Page 15: Technical Support / Declaration Of Conformity

    CCEI Inc. (Quebec 1170122155) declares that the Oxeo VP & Oxeo LT VP is compliant with the safety and electromagnetic compatibility requirements of European directives 2006/95/CE and 2004/108/CE. The product Oxeo VP & Oxeo LT VP is UL certified in the file E524688 Pierre-Yves Flattot...

This manual is also suitable for:

Oxeo lt vp

Table of Contents