ccei Phileo VP Technical Manual

ccei Phileo VP Technical Manual

Automated and connected ph controller
Hide thumbs Also See for Phileo VP:

Advertisement

Quick Links

Table of Contents

1. Important Safety Instructions ....................................................................................................... 2
2. Packing Content .......................................................................................................................... 2
3. Description .................................................................................................................................. 3
4. Technical Specifications .............................................................................................................. 3
5. Installation ................................................................................................................................... 4
5.1. Wall Mounting ................................................................................................................. 4
5.2. Hydraulic Connection ....................................................................................................... 4
5.3. Accessories Positioning (Zelia POD, for 1.5" pipes) ......................................................... 5
5.4. Accessories Positioning (for 2" Piping) ............................................................................ 6
5.5. pH Sensor, Flow Switch and Tube Connection ................................................................. 7
5.6. Electrical Wiring .............................................................................................................. 8
6. Smartphone Application .............................................................................................................. 9
6.1. App Download ................................................................................................................. 9
6.2. Connect your Device to Vigipool ..................................................................................... 9
7. Setting the Phileo ...................................................................................................................... 10
7.1. Control Interface ............................................................................................................. 10
7.2. Getting Started with the Phileo ....................................................................................... 10
7.3. Additional Parameters to be set via the Smartphone App ................................................ 12
8. Operating the Phileo .................................................................................................................. 13
8.1. Information Delay and Non-Active Injection .................................................................. 13
8.2. Setpoint Selection ........................................................................................................... 13
8.3. Measured Value Display ................................................................................................. 14
8.4. Product Factory Reset ..................................................................................................... 14
9. Sensor Maintenance ................................................................................................................... 14
A. Technical Support / Declaration of Conformity .................................................................... 15
CONT0045 v1.0EN (11/01/2022)
Technical Manual
Phileo VP
Automated and Con-
nected pH Controller
PF10J050

Advertisement

Table of Contents
loading

Summary of Contents for ccei Phileo VP

  • Page 1: Table Of Contents

    Technical Manual Phileo VP Automated and Con- nected pH Controller PF10J050 Table of Contents 1. Important Safety Instructions ....................... 2 2. Packing Content .......................... 2 3. Description ..........................3 4. Technical Specifications ......................3 5. Installation ........................... 4 5.1. Wall Mounting ......................... 4 5.2.
  • Page 2: Important Safety Instructions

    MUST READ AND UNDERSTAND THE WARNINGS AND INSTRUCTIONS IN THIS MANUAL BEFORE USING THIS PRODUCT. This manual contains instructions for installing and using the Phileo VP. Contact CCEI for any questions about the equipment. To the installer: This manual contains important safety information on the instal- lation and use of this product.
  • Page 3: Description

    (caustic) and considerably reduces the effectiveness of the chlorine. The user can set the Phileo VP in pH- or pH+ mode. In pH- mode, the Phileo VP injects pH minus into the pool and, in pH+ mode, it injects pH plus. To avoid possible measurement errors, it is recommended to inspect the calibration of the probe once a month.
  • Page 4: Installation

    Technical Manual Phileo VP v1.0EN WiFi 802.11 b/g/n and "dual band" (2.4 GHz only) 5. Installation Always mount the controller in a safe and non-floodable area. Never bury the pow- er cable. The controller must not be installed directly outside, it must be protected from rain, cleaning or watering jets and UVs (sunlight).
  • Page 5: Accessories Positioning (Zelia Pod, For 1.5" Pipes)

    Technical Manual Phileo VP v1.0EN When installing and using the Zelia Pod, make sure that it is loaded relative to the water level of the pool, so that it is constantly filled with water and free of air. If air is present in the measurement chamber, the sensor readings may be distorted.
  • Page 6: Accessories Positioning (For 2" Piping)

    Technical Manual Phileo VP v1.0EN • E: Housing for pH injection • F: Housing for injection (not used) 2. pH sensor installation: Open the pH probe box and remove the storage solution. Carefully place the probe in the slot (B or C).
  • Page 7: Ph Sensor, Flow Switch And Tube Connection

    Technical Manual Phileo VP v1.0EN Before installation, water must be drained from the piping. For each location, drill a hole in the top of the pipe between 11/16" and 7/8" (18 - 22 mm) in diameter. Support clamp with 1/2" thread: mount the supplied gland using Teflon tape. Insert the pH probe carefully, until it reaches the bottom of the pipe.
  • Page 8: Electrical Wiring

    Technical Manual Phileo VP v1.0EN For (D): the adapter on the left is for the aspiration of the pH corrector, and the one on the right is for the injection of the product into the pool water 5.6. Electrical Wiring Risk of electric shock.
  • Page 9: Smartphone Application

    For Android® devices: For Apple® devices: The Phileo VP includes a Bluetooth® and Wi-Fi transmitter, which allows your device to be controlled by a smartphone or tablet. To control the Phileo, an iOS (Apple®) or Android® device with a Blue- tooth®...
  • Page 10: Setting The Phileo

    7. Setting the Phileo The Phileo VP can be set up via the interface of the box or via the smartphone app available on iOS® and Android®. We encourage you to use the app, which gives access to additional settings, especially for sensor calibration.
  • Page 11 – And that a device is already configured as Vigipool "Master", restart the Vigipool "Master" device if it has been powered for more than one minute. Your Phileo VP will connect to the Vigipool "Master": it will stop flashing in white and go to normal operation mode.
  • Page 12: Additional Parameters To Be Set Via The Smartphone App

    Technical Manual Phileo VP v1.0EN The colour of the RGB LED (C) lights up depending on the difference compared to the expected measurement: • Green: very small deviation between the measured and expected values (devia- tion less than 0.1). • Yellow / Orange: small deviation between the measured and expected values (deviation between 0.1 and 0.5).
  • Page 13: Operating The Phileo

    • Volume adjustable from 0 to 50 L • Increment of 1 L at a time 8. Operating the Phileo Phileo VP do not perform measurements: • during the first 2 minutes after powering up (to wait for the stabilization of the measurement), •...
  • Page 14: Measured Value Display

    Technical Manual Phileo VP v1.0EN 8.3. Measured Value Display The 5 indicator LEDs on the front panel display the measured ORP value (here 7.2). If the ORP is between two graduations, the LED of the previous graduation remains fixed (here 7.2), and the LED below or above, depending on the reading direction of the ORP, flashes slowly.
  • Page 15: Technical Support / Declaration Of Conformity

    USA: na.ccei-pool.com/us / Tel: +1 424 800 2191 Canada: na.ccei-pool.com/ca / Tel: +1 514 963 4226 CCEI Inc. (Quebec 1170122155) declares that the Phileo VP is compliant with the safe- ty and electromagnetic compatibility requirements of European directives 2006/95/ CE and 2004/108/CE. The product Phileo VP is UL certified in the file E524688...

This manual is also suitable for:

Pf10j050

Table of Contents