Possible screens: Overview

The most common screens are as follows:
+
c1
c3
a

Home screen

b
Main menu screen
c
Lower level screens:
c1: Setpoint screen
c2: Detailed screen with values
c3: Screen with weather-dependent curve
c4: Screen with schedule
5.3.1
Home screen
Press the
button to go back to the home screen. You see an
overview of the unit configuration and the room and setpoint
temperatures. Only symbols applicable for your configuration are
visible on the home screen.
a1
a2
k
55
j1
45
j2
j3
21
35
i
h1
h2 h3
Possible actions on this screen
Go through the list of the main menu.
Go to the main menu screen.
Enable/disable breadcrumbs.
Item
a Domestic hot water
a1
Domestic hot water
55
a2
Measured tank temperature
EWSAH/X06(U)D
Daikin Altherma 3 WS
4P675761-1C – 2023.02
a
OR
b
c
c2
c4
26 Feb 2022
b
22:19
c
d
e
6
f1
1.6
bar
f2
f3
h4
g1
g2
Description
(a)
Item
b Current date and time
c Disinfection / Powerful
Disinfection mode active
Powerful operation mode active
d Emergency
Heat pump failure and system operates in
Emergency mode or heat pump is forced off.
e Space operation mode
Cooling
Heating
f Outdoor / quiet mode
6
f1
Measured outdoor temperature
f2
Quiet mode active
f3
Central water loop circuit
g Indoor unit / domestic hot water tank
g1
Floor-standing indoor unit with integrated tank
g2
Water pressure
h Main zone
h1 Installed room thermostat type:
Unit operation is decided based on the ambient
temperature of the dedicated Human Comfort
Interface (BRC1HHDA used as room thermostat).
Unit operation is decided by the external room
thermostat (wired or wireless).
No room thermostat installed or set. Unit operation
is decided based on the leaving water temperature
regardless of the actual room temperature and/or
heating demand of the room.
h2 Installed heat emitter type:
Underfloor heating
Fancoil unit
Radiator
21
h3
Measured room temperature
35
h4
Leaving water temperature setpoint
i
Holiday mode
Holiday mode active
j
Additional zone
j1 Installed room thermostat type:
Unit operation is decided by the external room
thermostat (wired or wireless).
No room thermostat installed or set. Unit operation
is decided based on the leaving water temperature
regardless of the actual room temperature and/or
heating demand of the room.
j2 Installed heat emitter type:
Underfloor heating
Fancoil unit
Radiator
45
j3
Leaving water temperature setpoint
5 Operation
Description
(a)
(a)
(a)
(a)
Operation manual
9