Balboa CLIM8ZONE II User And Service Manual page 15

Spa heat pump
Hide thumbs Also See for CLIM8ZONE II:
Table of Contents

Advertisement

Press
button to advance to the second password digit and enter "8" by pressing
Press
button to submit the password. After entering, select or change parameters by using
buttons
Press
button to make entry changes or confirm and return to the viewing status.
Parameter
Parameter name
code
P01
Return Difference for
Target Water Temp.
P02
Reserved
P03
Setting temp. In automatic mode
P04
Cooling setting temp.
P05
Heating setting temp.
P06=TP4
The setting temp. that Exhaust
temp. too high protection
P07=TP0
Recover The setting temp. from the
too high exhaust temp.
P08
Compressor current protection
P09
Inlet water temp. compensation
P10
Reserved
P11
Defrosting cycle
P12
Defrosting enters the temp.
P13
Defrosting time
P14
Desrosting exit temperature
P15
Temp. difference between
defrosting environment and coil
pipe
P16
Ambient temperature of the
defrosting
P17
Expansion valve cycle
P18
Overheat Degree in Heating Mode
System parameter table
Adjust range
1℃~18℃
--
5℃~40℃
8℃~28℃
15℃~40℃
80℃~125℃
50℃~100℃
2A~50A
-5℃~15℃
--
20MIN~90MIN
-15℃~-1℃
2MIN~20MIN
1℃~40℃
0℃~15℃
0℃~20℃
20-90
-5-10
or
buttons,
Default value
1℃(2℉)
--
27℃(40℉)
27℃(81℉)
27℃(79℉)
110℃(230℉)
90℃(194℉)
Reserved--Without
this function
0℃(0℉)
--
40MIN
-3℃(27℉)
5MIN
18℃(64℉)
5℃(10℉)
17℃(63℉)
30
3
or
15