6-3
Blade clamp section
6-3-1
Disassembling
1
Remove Shoe. (6-2-1)
Fig.6
[1]
1R312
Fig.7
[1]
1R049
Fig.8
[1]
2
It is easy to disassemble by holding the machine [1]
with the tip faced upward with 1R312.
3
Plug the cord in the outlet and move Blade clamp
section to the most forward position by pulling
Switch slightly. Then unplug the machine.
4
Remove Protector [1].
It is easy to disassemble by putting 1R049 under
Blade clamp section to prevent it from falling down.
5
Remove Retaining ring (EXT) 18 [1] from the end
with a slotted screwdriver, then slide the blade
along the ring while rotating.
7 / 32
Tips