LINCOLN
LISTED
38h9
U.S. Patent
IND. CONT.
EQ.
Series "B"
Model 84530
SYSTEM SENTRY™
APENTAIR AIR COMPANY
SENSOR CONTROLLER - EXTERNAL SCAN
OWNER/OPERATOR
MANUAL
It is the
responsibility
of the Owner/Operator
to properly
use and maintain
this equipment
The
Instructions
and
Warnings
contained
in this
manual
shall
be read
and
understood
by the
Owner/Operator
prior
to
operating
this equipment
It is the
responsibility
of the Owner/Operator
to maintain
the Iegibility
of all Warning
and Instruction
labels
The
Owner/Operator
shall
retain
this
manual
for future
reference
to important
Warnings,
Operating
and
Maintenance
Instructions.
CONTENTS
PAGE
Description
1
Liquid Crystal
Display
2
Programming
Mode
2
Run Mode
4
Alarm Messages
4
Installation
of Sensors
5
Electrical
shock
hazard.
Do
Not
subject
sensor
Field Connections
6
Turn off and lock out power
bodies
to pressure
greater
Service
Parts
7
before
opening
enclosure.
than
6,000
PSIG.
Specifications
8
System
Accessories
8
DESCRIPTION
When programmed
as a Sensor
Controller,
Model 84530
wiII
verify delivery
of Iubricant
into a bearing
The Sensor
Controller
can only detect
faults
which
occur
between
the sensor (located
in the delivery
Iine at the bearing
lube inlet) and the flow source. Continuous flow or no flow during
the delivery
cycle are both signaled
as a fault by this system.
A minimum of 30 seconds
between
the end of one flow to the
beginning
of the next flow is required
for detection.
Sensors
wiII function
at any pressure
up to 6,000
PSIG. The
temperature
of the material
which is to be delivered
past the
sensors must be between
32° F to 145° F for effective operation
of the system. Viton seals and checks in the sensors allow their
use in systems
distributing
synthetic
lubricants
as well as
petroleum
based lubricants.
For reliable
operation,
sensors
can only be used with Model
84530.
When
power
is turned
on to the Controller
and
a Lube
cycle
is immediately
initiated,
a sensor
fault
may occur
due to the sensors
not having
enough
time
to warm.
It is
recommended
that the Delay
Alarm
be set at 2 in order
to
prevent
a nuisance
alarm.
An external
switch
(contact
closure)
or an external
signal
(120/230
VAC) wiII initiate a scan period (amount
of time that
the sensors are scanned
for lube flow). The scan period IS the
time that the external
switch IS closed.
When the external
switch closes the amber Iight turns on and
the timer on the display begins timing up from zero, indicating
the amount of time the external
switch has been closed. If the
sensors
are satisfied
while the external
switch is closed
the
amber
Iight wiII turn off. When the external
switch opens the
timer on the display IS reset to zero and begins timing up again,
indicating
how long since the last scan period
If the sensors
are not satisfied
while the external
switch
is
closed the following
will happen:
Amber Iight on door remains
on.
The timer on the screen is reset to zero and begins timing up
Indicating
when the last scan period took place.
If, after thirty seconds
following
the external
switch opening,
the sensors
still have not been satisfied
and the delay alarm
counter
has reached
its set value the following
will happen
Red light on door turns on
Alarm relay contact
closes
Alarm
message
wiII
alternate
with
Scan
Timer
on
enclosure
door
If lube flow takes place while the external
switch iS open, the
fault wiII be cleared
However,
the next time the external
switch
closes the amber
Iight wiII not turn on
Due to the numerous
options available,
the customer
can field
program
the controller
to match
the system
requirements
Programming is easily accomplished
by following a user friendly
menu displayed
on the LCD and pressing
the active buttons
beneath
the display
An internal jumper
pin provides
security
against unauthorized
programming
All programmed
parameters
are automatically
stored
in a nonvolatile
memory
A Review
Screen
can be easily
activated
to display
what
has been
programmed
Programmed
values
can
be
changed
whenever
necessary
There
are three
Iights on the enclosure
door to Indicate
the
status of the system
Green
- Power On
Amber
- Sensors
are waiting to be satisfied.
Red - Alarm
If an alarm occurs, the cause
of the alarm wiII appear
on the
LCD Turning off power to the controller
when in alarm will reset
the alarm
The LCD is capable
of displaying
the following
messages
Amount of elapsed
time since the External
switch opened
Amount
of elapsed
time
that
the
External
switch
has
been closed
Number
of times each bearing
has received
lube
Indicates
what sensor did not receive
lube
Indicates
what sensor
has a broken
wire
Indicates
what sensor
has a shorted
wire
LINCOLN
One Lincoln Way
Copyright 1993
Section
-
C8
St. Louis, Missouri 63120-1578
Printed inU.S.A.
A
PENTAIR COMPANY
(314)679-4200
Page
-
247-5A
JAN-93
FORM 402435