Disassembly Procedure - Mitsubishi Electric PUZ-SWM60VAA Service Manual

Air to water heat pump units
Table of Contents

Advertisement

[Outdoor unit -– Capacity setting display] (Request code: "70")
Data display
Capacity
9
35
10
50
11
60
14
71
20
100
25
125
28
140
40
200
50
250
[Outdoor unit – Setting information] (Request code: "71")
Data display
0
0

DISASSEMBLY PROCEDURE

11
OPERATING PROCEDURE
1. Removing the service panel and top panel
(1) Remove the service panel fixing screws (3 for front and 1
for right/ 5 × 12), then slide the service panel downward
to remove it.
(The service panel is fixed to the side panel (R) with a
hook on the right side.)
(2) Remove the top panel fixing screws (3 for front, 3 for rear
and 1 for right/ 5 × 12) to remove the top panel.
Note 1: When removing service panel and top panel at the
same time, count 2 less screws since they share
the screws.
OCH809A
Setting information 1
Setting information 1
Setting information 2
Setting information 2
Photo 1
Wire grille
fixing screws
73
Display
Defrost mode
0
Standard
1
For high humidity
Single-/
Heat pump/
Display
Display
Single-/ 3-phase
cooling only
3-phase
0
0
Single-phase
Single-phase
1
1
2
2
3-phase
3-phase
3
3
Cooling only
: Indicates the visible parts in the photos/figures.
: Indicates the invisible parts in the photos/figures.
PHOTOS/ FIGURES
Top panel fixing screws
Wire grille
Wire grille
fixing screws
Heat pump/
cooling only
Heat pump
Heat pump
Cooling only
Cooling only
Heat pump
Heat pump
Cooling only
Top panel
Service panel
fixing screws
Service panel
Side panel (R)
Service panel
fixing screws

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents