CONTENTS Safety and warnings Vacuum seal drawer models Accessory door panels (purchased separately) Unpack your product Electrical specifications Parts supplied Tools required Product dimensions Cabinetry dimensions Installation options Prior to installation Installing the drawer install front panel (sold separately) Adjusting the height Installer checklist...
SAFETY AND WARNINGS WARNING! WARNING! Electric Shock Hazard Tip Hazard Failure to follow this advice may result in This product may tip. Keep children away and electrical shock or death. take care. Failure to follow this advice may result in injury. •...
When installed in combination with a companion product, the companion product can be placed directly onto the appliance. A built-in shelf at the base of the cabinetry must be VB60SMB1-SET, VB60SMG1-SET able to support the weight of both products. & VB60SDB1-SET Ensure the cabinetry is square and level and with correct dimensions.
UNPACK YOUR PRODUCT ELECTRICAL SPECIFICATIONS Remove the Vacuum Seal Drawer and accessories box from the packaging. Recycle the All electrical work must be done by a qualified electrician, or a Fisher & Paykel trained and materials that can be reused. Dispose packaging materials in accordance with local regulations supported service technician.
PARTS SUPPLIED TOOLS REQUIRED VACUUM SEAL DRAWER VACUUM SEAL DRAWER MINIMAL VB60SMB1-SET & VB60SMG1-SET CONTEMPORARY MINIMAL VB60SMB1-SET & VB60SMG1-SET SERVICE & WARRANTY VB60SDB1-SET SERVICE ET GARANTIE CONTEMPORARY ΣΈΡΒΙΣ ΚΑΙ ΕΓΓΎΗΣΗ VB60SDB1-SET SERVIZIO E GARANZIA SERVICE & GARANTIE HUOLTO JA TAKUU...
PRODUCT DIMENSIONS VB60SMB1-SET VB60SMG1-SET PRODUCT DIMENSIONS VB60SDB1-SET A Overall height of drawer B Overall width of drawer C Overall depth of drawer* D Height of chassis E Width of chassis** F Depth of chassis*** G Height of drawer front panel...
CABINETRY DIMENSIONS PROUD INSTALL PROFILE PLAN VB60SMB1-SET FLUSH INSTALL VB60SMG1-SET CABINETRY DIMENSIONS VB60SDB1-SET A Minimum inside height of cavity B Minimum inside width of cavity C Minimum inside depth of cavity D Overall width of cabinetry E Minimum clearance between top of front panel and upper...
INSTALLATION OPTIONS STANDALONE INSTALLATION COMBINED WITH SINGLE OVEN COMBINED WITH COMPANION PRODUCT Suitable for Minimal and Contemporary 60cm Vacuum seal The 60cm Vacuum seal drawer can fully support a 60cm The 60cm Vacuum seal drawer can fully support a 60cm drawers.
PRIOR TO INSTALLATION INSTALL THE AIR FILTER REMOVE THE TRANSIT SCREWS The transport screws must be removed before starting up for the first time to avoid damage to the drawer. power cable holder Unscrew the transport screws from under the power cable and holder. transport screws locking cap...
INSTALLING THE DRAWER Connect the power plug into the power outlet. Open the drawer and extend fully. Slide the drawer carefully into the cabinetry. Push the drawer back into the Secure the attachment flanges of cabinetry. the drawer to the side edges of cabinetry with 4x20 T20 star head Ensure the side brackets engages countersunk screws.
INSTALL FRONT PANEL (SOLD SEPARATELY) ADJUSTING THE HEIGHT The front panel of the drawer can be adjusted vertically to align with the surrounding cabinetry. Ensure the lower adjustment clip is engaged on the outside of the drawer, between the screw and the drawer. Open the drawer fully, and slightly loosen the two screws.
INSTALLER CHECKLIST PRODUCT OFF USER PRESSES ON/OFF BUTTON IMPORTANT! PRODUCT OFF USER PRESSES ON/OFF BUTTON Read all installation instructions in this manual to see if the unit has been correctly installed. ALL OT Ensure that installation has been completed correctly before use. TEMPER MEDIUM ALL OT...