User Programming - Basic System
Table 1 - Dipswitch Options for Switches SW1 - SW4:
(Shaded areas indicate default values - Unit power source must be removed before altering dip switch settings)
Main Board SW2
Station 21 call button NORMAL priority
SW2-1
Station 22 call button NORMAL priority
SW2-2
SW2-3
Station 23 call button NORMAL priority
SW2-4
Station 24 call button NORMAL priority
2 digit dialing plan
SW2-5
SW2-6
No queue tone to speaker/attendant
SW2-7
No dial tone to Attendant
SW2-8
No handsfree alert tone to speaker
Main Board SW3
SW3-1
No 1-way page alert tone to speaker
SW3-2
No ringback tone to Attendant
(HF or group page)
SW3-3
No 15 second privacy tone to HF speaker
SW3-4
Priority phone controls local V-2924 only
External priority blocks local priority
SW3-5
(see "Ringing Pattern Options" table below)
SW3-6
SW3-7
(see "Ringing Pattern Options" table below)
Use internal time and emergency tones
SW3-8
1
Tone will be heard regardless of SW3-2 setting if SW2-8 or SW3-1 is turned on
SW3-6
American
OFF
OFF
Dutch
ON
British
Background Music Options
Main Board SW1
SW1-1
SW1-2
SW1-3
SW1-4
Override Port Options
Main Board SW4
Switch OFF
1
Ringing Pattern Options
SW3-7
OFF
2 seconds ON, 4 seconds OFF
ON
1 second ON, 4 seconds OFF
OFF
Double ring burst, x seconds OFF
Switch OFF
No BGM to group 1
No BGM to group 2
No BGM to group 3
No BGM to group 4
Switch OFF
Tel. System Page Port Access
Station 21 call button LOW priority
Station 22 call button LOW priority
Station 23 call button LOW priority
Station 24 call button LOW priority
3 digit dialing plan
Queue tone to speaker/attendant
Dial tone to Attendant
Handsfree alert tone to speaker
1-way page alert tone to speaker
Ringback tone to Attendant
(HF and group page)
15 second privacy tone to HF speaker
Priority phone controls all connected V-2924s
Local priority overrides external priority
Use V-9927A for time and emergency tones
Switch ON
BGM to group 1
BGM to group 2
BGM to group 3
BGM to group 4
Switch ON
Loop Start Trunk Port
11
Switch ON
Stations 1 - 6
Stations 7-12
Stations 13-18
Stations 19-24
947211