Troubleshooting - Mosa GE 7554 YDE-L Use And Maintenance Manual

Table of Contents

Advertisement

Troubleshooting

● Have qualified personnel do maintenance and troubleshooting work.
● Stop the engine before doing any work inside the machine. If for any reason the machine must be operated while working inside, pay attention moving
parts, hot parts (exhaust manifold and muffler, etc.) electrical parts which may be unprotected when the machine is open.
● Remove guards only when necessary to perform maintenance, and replace them when the maintenance requiring their removal is complete.
● Use suitable tools and clothes.
● Do not modify the components if not authorized.
- See pag. M1.1 -
Problem
The motor does not start up, or
starts up and then stops imme-
diately
The motor does not accelerate.
Inconstant speed.
Too little power provided by
motor.
Other problems or inconvenien-
ces on the engine
Absence of output voltage
No-load voltage too low or too
high
Corrected no-load voltage too
low with load
Unstable tension
!
ATTENTION
Possible cause
1) Lack of fuel in tank or fuel tap closed
2) Fuel filter clogged
3) Air leaks in fuel system
4) Battery not activated, low or faulty
5) Battery cable terminals loose or corroded
6) Motor stopping device defective (solenoid)
7) Other causes
1) Air or fuel filter clogged
2) Overload
GENERATOR
1) Protection tripped due to overload
2) Insulation monitor device tripped
3) Protection devices defective
4) Alternator not sparked
5) Alternator defective
6) Faulty AVR
7) AVR fuse blown
1) Incorrect motor running speed
2) Alternator defective
3) AVR out of calibration
4) Faulty AVR
1) Incorrect motor running speed due to over-
load
2) Load with cos ϕ less than the nominal one.
3) Alternator defective
4) Faulty AVR
1) Contacts malfunctioning
2) Irregular rotation of motor
3) Alternator defective
ENGINE
1) Refill the tank. Open the fuel tap
2) Replace
3) Check the feeding circuit
4) Activate, recharge, or replace the battery
5) Tighten and clean. Replace if corroded.
6) Replace
7) Consult the motor Operating Manual.
1) Clean or replace filter element(s).
Refer to engine manual
2) Check the connected loads and if recessary reduce
Consult the motor Operating Manual.
1) Check the load connected and diminish
2) Check on the generating set and on the entire
installation: cables, connections, utilities connected
have no defective sheathing
3) Replace
4) Carry out external spark test as indicated in alternator
manual. Ask for intervention of Service Department
5) Check winding, diodes, etc. on alternator (Refer to
alternator manual). Repair or replace.
Ask for intervention of Service Department
6) Replace
7) Replace
1) Check position of accelerator lever.
Regulate speed to its nominal no-load value
2) Check winding, diodes, etc. on alternator (Refer to
alternator manual). Repair or replace.
Ask for intervention of Service Department
3) Adjust potentiometer of the AVR
4) Replace
1) Check the load connected and diminish
2) Reduce or rephase load
3) Check winding, diodes, etc. on alternator (Refer to
alternator manual). Repair or replace.
Ask for intervention of Service Department
4) Replace
1) Check electrical connections and tighten
2) Ask for intervention of Service Department
3) Check winding, diodes, etc. on alternator (Refer to
alternator manual). Repair or replace.
Ask for intervention of Service Department
GE 7554 YDE-L
40.2
REV.0-11/10
Solution
M

Advertisement

Table of Contents
loading

Table of Contents