MAINTENANCE

WARNING! As your cooler is mounted on
the roof, we suggest that any maintenance
or checks be carried out by an authorised
Seeley International dealer or service agent.
Climbing onto the roof can be hazardous
and could result in injury to you and
damage to your property.
For gaining access to the cooler refer to the
Removing Pad Frames section.
Maintenance Schedule servicing is essential to
ensure the cooler operates efficiently for many
years. It must be carried out by a qualified,
licensed technician. The following pages
outline the suitable maintenance requirements
to ensure that your cooler continues to operate
efficiently.
We require that the following components
and the operation thereof, be checked/
serviced after the first year, then every 2
years for residential purposes, or every year
for commercial purposes, as Maintenance
Schedule servicing. Refer to the Maintenance
Schedule section.
• Water distribution spreader trays.
• Pump.
• Drain valve.
• Solenoid and associated filter / fittings.
• Fan motor operation.
• Float valve.
• Salinity probes etc
Maintenance Schedule servicing should be
performed before the summer season. It is
important to note that all evaporative coolers
have components that may need periodic
replacement (eg. filter pads, hoses, o-rings
etc).
Note! Failure to carry out the Maintenance
Schedule services will void your warranty
cover.
Note! Maintenance Schedule servicing
may be required more frequently in adverse
environmental situations or where the
appliance is installed in non-domestic
applications. Please consult with the installer
or service personnel to determine if more
frequent servicing is required.

SEASONAL MAINTENANCE

Seasonal Maintenance is only required if you
have a cooler fitted with a bleed system. If your
cooler is fitted with a drain valve, no Seasonal
Maintenance is required.
Seasonal Maintenance services must be
performed before and after the summer
season.

Pre-Season

1. Remove the pad frames as shown on the
next page.
2. Ensure the power is off at the isolating
switch inside the cooler.
3. Gently wash the pad frames to remove
any dust build up during the winter.
Note! Do not wash the pads with high
pressure water spray. If the pads are
salted-up, replace them.
4. Check for water leaks. Check operation of
the float valve.
5. Turn on the water supply to the cooler.
6. Switch on the isolating switch.
7. Refit the pad frames.
8. Run the cooler.
WARNING! Ensure the pad frames are fitted
when operating the cooler.

End of Season

1. Turn off the water supply to the cooler.
2. Remove the pad frames
3. Turn off the power at the isolating switch
inside the cooler.
4. Check and clean the water distributing
spreader tray channels under the lid.
5. Drain the tank.
6. Thoroughly clean the tank, pump filter and
salinity probe (if fitted).
7. If a drain valve is fitted it will automatically
drain. If a bleed funnel is fitted, remove it
from the tank as shown below. Keep the
O'Ring in a safe place for later use.
8. Refit the pad frames.