SEASONAL MAINTENANCE
Maintenance Schedule servicing is essential
to ensure the cooler operates efficiently for
many years. Seasonal Maintenance is only
required if you have a cooler fitted with a
bleed system. The following pages outline the
suitable maintenance requirements to ensure
that your cooler continues to operate efficiently.
If your cooler is fitted with a drain valve, no
Seasonal Maintenance is required. However,
we require that the following components and
the operation thereof, be checked after the
first year, then every 2 years as Maintenance
Schedule servicing.
• Water distribution channels.
• Pump.
• Drain valve.
• Solenoid and associated filter / fittings.
• Fan motor operation.
• Float valve.
• Salinity probes.
Seasonal Maintenance services must be
performed before and after the summer
season. Maintenance Schedule servicing
should be performed before the summer
season. It is important to note that all
evaporative coolers have components that
may need periodic replacement (eg. filter pads,
hoses, o-rings etc).
WARNING! As your cooler is mounted on the
roof, we suggest that any maintenance or
checks be carried out by an authorised Seeley
International dealer or service agent. Climbing
onto the roof can be hazardous and could
result in injury to you and damage to your
property.
Note! Maintenance Schedule servicing
may be required more frequently in adverse
environmental situations and very dusty areas.

PRE-SEASON

• Turn off power supply to the cooler.
• Inspect external cabinet, dropper and
flashing for any damage or deterioration.
• Check water supply to the cooler.
• Remove pad frames
• Ensure power is off at isolating switch inside
the cooler.
• Gently wash pad frames to remove any dust
build up during winter. IMPORTANT! Do not
damage the pads with high pressure water
spray.
• Inspect pad retention pins and washers for
damage and that they are securely fitted.
• Replace the bleed system if it was removed
during previous maintenance and ensure
the O'ring is fitted. (If the cooler is fitted with
a drain valve this will not be necessary as
it will automatically close when the cooler
turns on.
• Check fan motor, mounts and blades for
damage.
• Turn on power supply to cooler and check
electrical isolation switch operates correctly.
• Turn on the water and then the power to
the cooler. Check water hose from pump to
distributor cap is secure.
• Check water distribution channels in the lid
are clean.
• Check drain hose from system is clear of
blockages and there are no leaks.
• Check operation of float valve.
• Refit the pad frames & run the cooler.
• Check MagIQtouch controller operation.
• Check that all pads are evenly wet.

END OF SEASON

• Turn off power supply to the cooler.
• External inspection of cabinet, dropper duct
and water supply valve.
• Turn off the water supply to the cooler.
• Remove the pad frames.
• Turn off the power at the isolating switch
inside the cooler.
• Check and clean the water distributing
channels in the lid.
• If a bleed system is installed, unclip and
remove the bleed funnel. Allow the tank
water to drain. Do not re-fit the bleed system
at the end of the season. Do not lose the
O'ring.
• Clean thoroughly the tank, pump filter and
salinity probe if fitted.
• If a Drain Valve is fitted it will automatically
drain. You can drain the cooler at any time
by accessing the menu item located in the
SETTINGS menu.
• Refit the pad frames.
WARNING! Ensure pad frames are fitted when
operating the cooler.
BREEZAIR TBQ/TBS OWNER'S MANUAL |
5