Hisense HRM260N6TSE User's Operation Manual page 11

Table of Contents

Advertisement

Available languages

Available languages

What you need to have before you begin
1. Power drill and 1/4" drill bit.
2. 1/2" or adjustable wrench.
3.lat blade and Philips head screwdrivers.
1
2
Saddle-type
one 1/4"
Shut Off valve
compression
(1/4" outlet)
4
5
1/4" extension
1 Coupler
tubing
4. You may need to purchase No.1, No.2,
and No.3 parts to complete connection.
You may find these items sold as a kit at
a local hardware store.
Connecting to the water
supply line
1. First, shut off the main water supply.
2.Using a power drill and a 1/4" drill bit drill
into the cold-water line and connect the
saddle-type shutoff valve.
Cold water line
Pipe clamp
Shut off Valve
3
1 ferrule
(sleeve)
6
2 Clips
3.Connect 1/4" extension tubing to shut off
valve outlet.
Saddle-Type
Shutoff Valve
Packing Nut
Outllet Valve
4. Flush the tubing. Turn the main water
supply on and flush out the tubing until the
water is clear. Then, shut the water off at
the water valve after about a quart of
water has flushed through the tubing.
5. Connect the extension tubing line with
the line on the back of the fridge via the
coupler. Fully insert the extension tubing
into the coupler, and then insert the clip
onto the coupler to lock in the tubing. Do
the same with the other end. After both
clips are inserted, check the line to make
sure it is held firmly by the clips.
Cold water line
Note
Ensure that the water line does not get
pinched or bent when installing.
This can result in improper water flow
through the line and will affect the
functionality of the fridge.
Compression Nut
1/4" Extension
tubing
Ferrule(sleeve)
Clip
Cold water line
Coupler