Symptom
FAN WILL NOT START
FAN IS "SWINGING" AS IT
RUNS
A FAN BLADE APPEARS TO
BE 'SAGGING'
For situations beyond the scope of this Guide, please call our Technical Service
Department at 1-844-591-FANS (3267), or email us at: fansupport@hunterfan.com.
24

TROUBLESHOOTING

• Verify that the fan's circuit breaker has power and that it is on.
• Check for secured plug connections. Each connection should be
checked to ensure they are fully engaged.
• Inspect for loose wiring connections. Each termination should be
checked to be sure they are firmly tightened.
• Check for correct fan blade installation. Be sure that all blades have
been properly installed according to color and are tightened.
• Ensure all downrod hardware has been tightened.
• Ensure fans distance is twice the diameter of the fan from the air
discharge locations.
• Make sure that the 'sagging' blade has been properly tightened.
Possible Solution