Logic Output (PL310QMT)
Output Voltage:
Output Current:
Output Terminal:
Output Protection:
Load Regulation:
Load Regulation:
GENERAL
Power Requirements:
Input Voltage:
Input Voltage Range:
Power Consumption:
30V/1A
15V/4A or 30V/2A
30V/3A
Environmental Operating Range:
Environmental Storage Range:
Weight:
30V/1A
15V/4A or 30V/2A
30V/3A
Size:
Electrical Safety:
EMC:
Fixed 5V ± 0.1V
0 to 1.5 Amps
4mm terminals on 19mm (0.75") spacing
Output will withstand up to 16V forward voltage. Diode clamped for
reverse voltages and up to 3 Amps reverse current.
<0.3% for 50% load change
<0.1% for 10% line change
Internally set for 110, 120, 220 or 240VAC 50/60Hz
± 10% of voltage setting
Single
75VA
150VA
250VA
5°C to 40°C, 20% to 80% RH
-20°C to +60°C
Single
4.0kg
5.0kg
6.0kg
155 mm wide x 170mm high x 265/300mm deep (single)
350mm wide x 170mm high x 265/300mm deep (dual)
425mm wide x 170mm high x 265/300 mm deep (triple)
Designed and manufactured to comply with IEC 348
Designed and manufactured to comply with EN50081-1/EN50082-1.
Dual
Triple
150VA
150VA
300VA
375VA
500VA
600VA
Dual
Triple
8.0kg
8.5kg
9.5kg
11.5kg
12.0kg
15.5kg