Note:
Overvoltage Category Definition
Category I: applies to equipment connected to a circuit where measures have been taken to
reduce transient overvoltage to a low level.
Category II: applies to equipment not permanently connected to the installation. For example,
appliances, portable tools and other plug-connected equipment;
Category III: applies to fixed downstream equipment, including the main distribution board. For
example,switchgear and other equipment in an industrial installation;
Category IV: applies to equipment permanently connected at the origin of an installation
(upstream of the main distribution board).For example, electricity meters, primary
overcurrent protection equipment and other equipment connected directly to
outdoor open lines.
Moisture Location Category Definition
Moisture parameters
3K3
Temperature Range
0~+40℃
Humidity Range
5%~85%
Environment Category Definition
Outdoor : the ambient air temperature is -20~50℃. Relative humidity range is from 4% to 100%,
applied to PD3.
Indoor unconditioned: the ambient air temperature is -20~50 ℃. Relative humidity range is from
5% to 95%, applied to PD3.
Indoor conditioned: the ambient air temperature is 0~40 ℃. Relative humidity range is from 5% to
85%, applied to PD2.
Pollution Degree Definition
Pollution degree 1: No pollution or only dry, non-conductive pollution occurs. The pollution has
no influence.
Pollution degree 2: Normally only non-conductive pollution occurs. However, a temporary
conductivity occasionally caused by condensation must be expected.
Pollution degree 3: Conductive pollution occurs. Or dry, non-conductive pollution becomes
conductive due to condensation, which is expected.
Pollution degree 4: Persistent conductive pollution occurs. For example, the pollution cause by
conductive dust, rain and snow.
39
Level
4K2
4K4H
-33~+40℃
-20~+55℃
15%~100%
4%~100%

7.2 Block Diagram

GEP series main circuit is shown in the below figure:
GEP12~20-L-10
GEP25~36-10
SWITCH
BOOST
DC
PV1+
PV1-
DC
BUS
DC
PV2+
DC
EMC
PV2-
DC
Filter
DC
PV3+
PV3-
DC
GEP30~35-L-10
GEP50~60-10
SWITCH
BOOST
DC
PV1+
DC
DC
PV2+
EMC
PV1-
Filter
DC
PV2-
DC
BUS
PV3+
DC
DC
DC
PV4+
EMC
PV3-
Filter
DC
PV4-
DC
PV5+
DC
DC
PV6+
DC
EMC
PV5-
Filter
DC
PV6-
DC
OUT FILTER
INV
AC RELAY
DC
AC
AC
EMC
Filter
Filter
AC
OUT FILTER
AC RELAY
INV
DC
AC
AC
EMC
Filter
Filter
AC
L1
L2
L3
N
PE
L1
L2
L3
N
PE
40