2. Data storage and display
Inverter stores the running information and fault records and display them on the LCD screen.
3. Parameter configuration
Inverter provides various parameter configurations for optional operation.
4. Communication interface
Inverter provides standard RS485 communication interface.
5. Protection functions
>Insulation resistance to ground surveillance.
>Input voltage monitor
>Residual current monitoring unit
>Anti-islanding protection
>PV array string fault monitoring
>DC switch
>DC SPD
>AC SPD
>SPD fault monitoring
>AC over curent protection
>Insulation monitoring

3.4 Package

3.4.1 Unpacking And Inspection
The unit is thoroughly tested and strictly inspected before delivery. Damage may still occur during
shipping.
1. Check the package for any visible damage upon receiving.
2. Check the inner contents for damage after unpacking.
3. Check the Package list and it is shown as below:
Inverter
Backboard
07
Positive DC Plug
Negative DC Plug
Connecting Terminal
RS-485 & DRED
Communication
Terminal
Fixed Screw
Connecting Terminal
Grounding
AC Cover
OT Terminal
Insulation Sleeve
3.4.2 Identify The Inverter
A nameplate is attached on the one side of the inverter. It provides the information about the type
of the inverter along with the most important specifications, marks of certifications, website and
serial number, which are all identified by manufacturer.
Image shown here is for reference only, the received products
A
may be different.
* * * * *
Item
Vmax PV: ****V
d.c.
MPPT voltage range: ***...***V
d.c.
A
Max. PV current: **/**/**A
d.c.
Isc PV: **.*/**.*/**.*A
d.c.
B
Rated grid voltage: 3/N/PE or 3/PE~ 380/400V
a.c.
AC-grid frequency: **/**Hz
B
Max current: **.*Aa.c.
C
Rated active power: **/**kW [1]
Max apparent power: **kVA
D
Inverter topology: Non-isolated
Power factor range: Default >*.**, *.*cap...*.*ind
Operating temperature range: -**...**°C
Overvoltage-category: DCⅡ; ACⅢ
IP degree: IP65
Protective class: ClassⅠ
C
S/N:
D
********************************** Co.,Ltd.
E-mail: **********@****.com
***-*****-**
S/N
Safe Screw
Expansion Bolt
WiFi Module
(WiFi communication
Quick Installation
Or without LCD)
Instruction
Description
Logo and inverter's type
Technical data of the inverter
Marks of certification institution of inverter
S/N No. and company's name, website and origin
Grounding Screw
SolarGo
(Inverter Without
Screen)
User's Guide of
SolarGo App
08

Advertisement

Table of Contents
loading

Table of Contents