Regular Inspection Instructions - Vmac H600013 Installation And Owner's Manual

Hydraulic driven air compressor
Table of Contents

Advertisement

Regular Inspection Instructions

Read the "Maintenance and Repair Safety" section prior to
performing any work on the system (beginning on page 53).
Wear appropriate Personal Protective Equipment and follow all
industry standard safety practices.
The VMAC supplied and approved compressor oil must be used in
this system. Failure to use this special oil will result in damage to
the compressor and will void warranty.
Do not overfill the system. Overfilling the system with oil can flood
the sight glass window and make the system appear empty.
Inspecting and Adding Compressor Oil
Ensure the unit is level and that the compressor system is depressurized and
cool to the touch.
Check the oil level in the sight glass and ensure that it is between the "MAX"
arrow and the "ADD" arrow.
If the level is below the "ADD" mark, perform the following steps:
Remove the fill cap (Figure 20).
Using a funnel, pour oil into the fill fitting until the oil level in the sight glass
reaches the "MAX" arrow.
A 45° #12 ORB fitting can be used to extend the fill port and ease
oil filling.
Replace the fill cap and tighten securely.
Oil fill cap
54
Figure 20 — Inspecting the oil
VMAC - Vehicle Mounted Air Compressors
Oil sight
glass
VMAC Technical Support: 888-241-2289
VMAC Knowledge Base: kb.vmacair.com

Advertisement

Table of Contents
loading

This manual is also suitable for:

H400014H400005