Xylem WTW SenTix H Operating Manual

Xylem WTW SenTix H Operating Manual

Ph combin. electrodes with liquid reference system and ground junction
Hide thumbs Also See for WTW SenTix H:

Advertisement

Quick Links

®
SenTix
H
®
SenTix
HW
®
SenTix
HWD
SenTix
PH COMBIN. ELECTRODES WITH LIQUID REFERENCE SYSTEM AND GROUND JUNCTION
®
OPERATING MANUAL
ba75739e02 07/2013

Advertisement

loading
Need help?

Need help?

Do you have a question about the WTW SenTix H and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Xylem WTW SenTix H

  • Page 1 OPERATING MANUAL ba75739e02 07/2013 ® SenTix ® SenTix ® SenTix ® SenTix PH COMBIN. ELECTRODES WITH LIQUID REFERENCE SYSTEM AND GROUND JUNCTION...
  • Page 2 ® SenTix For the most recent version of the manual, please visit www.WTW.com. Copyright © Weilheim 2013, WTW GmbH Reproduction in whole - or even in part - is prohibited without the express written permission of WTW GmbH, Weilheim. Printed in Germany. ba75739e02 07/2013...
  • Page 3: Technical Data

    ® SenTix Technical data Technical data General data WTW model Reference electro- Junction Special features lyte ® SenTix KCl 3 mol/L, Ag free Ground Adjustable ground junc- tion ® SenTix KCl 3 mol/L, Ag free Ground Adjustable ground junc- tion ®...
  • Page 4 ® Technical data SenTix Commissioning, measuring, calibration Commissioning The combination electrode is filled with reference electrolyte solution in the factory. Prepare the combination electrode for measuring as follows:  Open the refilling opening for the reference electrolyte solution. Depend- ing on the model, the stopper of the refilling opening is an elastomer stop- per or a slider.
  • Page 5 ® SenTix Technical data Ground junction of With the ground junction of the SenTix H and SenTix HW combination elec- SenTix H and trodes, the electrode outflow can be adjusted with a thread: SenTix HW  Hold the combination electrode with the pH glass membrane pointing downward.
  • Page 6 ® Storage SenTix Subsequent cali- The frequency of subsequent calibrations depends on the application. Many brations meters provide an option where you can enter a calibration interval. After the calibration interval has expired, the meter will automatically remind you of the due calibration.
  • Page 7: Maintenance And Cleaning

    ® SenTix Maintenance and cleaning Maintenance and cleaning Refilling the During operation, a small amount of reference electrolyte leaks through the reference junction from the combination electrode into the test sample. If the level of ref- electrolyte erence electrolyte becomes too low with time, refill it through the refilling opening.
  • Page 8: Wear Parts And Accessories

    ® Wear parts and accessories SenTix If you want to clean and rinse the ground junction, you can open it as follows:  SenTix H and SenTix HW: completely unscrew the ground stopper (see figure on Seite 5).  SenTix HWD: slide the ground sleeve from the ground stopper towards the shaft while turning it slightly.
  • Page 12 150 countries, we have strong, long-standing relationships with customers who know us for our powerful combination of leading product brands and applications expertise, backed by a legacy of innovation. For more information on how Xylem can help you, go to www.xyleminc.com Wissenschaftlich-Technische Werkstätten GmbH Dr.-Karl-Slevogt-Straße 1...

This manual is also suitable for:

Wtw sentix hwWtw sentix hwd