3-4. Indoor Side Tubing

Arrangement of tubing by direction
1) Left side, left bottom or right side, right bottom tubing
Cut out the corner of the right/left frame with a hacksaw or the like.
Grille
Left tubing outlet
2) Right-rear or left-rear tubing
In this case, the corner of the frame need not be cut.
3-4-1. Right-rear side, right side, right-bottom side tubing
Be sure to insulate the drain hose and refrigerant tubing to run through the rooms.
Mounting the indoor unit
1) Assemble the refrigerant tubing, drain hose and wiring together with the armoring tape.
Do not wind the tape forcibly more than necessary.
The drain hose should be positioned below the tubing not to apply too much tension. (Cross-
section view)
2) Push the wiring, refrigerant tubing and drain hose through the hole in the wall. Mount the
indoor unit to be seated so it is caught on the tabs of the installation plate.
Installation plate
Apply putty or caulking
materials around the hole.
Cover
Refrigerant tubing
Refrigerant tubing
wiring
Drain hose
Drain hose
Wiring
Cross-section view
Indoor unit
Wiring
Refrigerant tubing *
Drain hose *
* Drain hose should be positioned below the refrigerant tubing.
26
Grille
Right tubing outlet
Indoor unit
Slant
Tubing