universalblue IGUAZU Instruction Manual page 32

Electric water heater 30l / 50l / 80l /100l
Table of Contents

Advertisement

Available languages

Available languages

Keep the hot water inside the appliance at a temperature of not
-
below 50°C.
In case a prolonged absence, adjust to max. for at least 24 hours.
-
Keep showers and taps clean of scale.
-
The thermostat is factory-set to max. Value: to change the setting
Disconnect the power supply then remove the protection cover, turn
the thermostat towards "+" to increase or "-" to decrease the
temperature. Refer to the relevant notch located on the thermostat
To prevent the formation of "legionella" an adjustment close to the
factory setting (towards the "+" notch) is advisable.
Safety limiting device
The appliances are equipped with a thermostat with safety limiting
device in compliance with current European standards. The limiting
device is activated in case of abnormal water heating, automatically
disconnecting the water heater-
The power resetting is manual (See fig.3.4).
To reset, please follow below stepts:
Disconnect the power supply
-
Remove the protection cover fixing screws
-
Lightly press the thermostat button, using an insulated object
-
with round tip.
The operation should be carried out by the means of a
qualified personal.
External cleaning
Clean the outer casing using neutral soapy solutions and never
organic solvent- based abrasive products (alcohol, petrol, etc.).