13 - OPTIONS
Options
High condensing temperature
Condensing temperature
limitation
Control for low cond.
temperature
Dry-cooler control
Energy Management Module
7" user interface
Input contact for Refrigerant
leak detection
Dual relief valves on 3-way
valve
Compliance with Swiss
regulations
Compliance with Russian
regulations
Compliance with Australian
regulations
Low noise level
Welded evaporator
connection kit
Welded condenser water
connection kit
Flanged evaporator water
connection kit
Flanged condenser water
connection kit
Thermal compressor
insulation
230V electrical plug
Free-cooling dry-cooler
control
Compliance with Morocco
regulation
No.
Description
Optimized compressor for operation at high
150
condensing temperature
Limitation of the maximum condenser leaving
150B
water temperature to 45°C
Output signal (0-10 V) to control the condenser
152
water inlet valve
Adaptation of the control box for
communication with the dry-cooler via a bus.
154
For dry cooler need to select the cabinet with
option control cabinet manage by the chiller
control
EMM Control board with additional inputs/
156
outputs. See Energy Management Module
option chapter
Control supplied with a 7 inch colour touch
158A
screen user interface
0-10 V signal to report any refrigerant leakage
in the unit directly on the controlller (the leak
159
detector itself must be supplied by the
customer)
Three-way valve upstream of dual relief valves
194
on the evaporator and the oil separator
Additional tests on the water heat exchangers:
supply (additional of PED documents)
197
supplementary certificates and test 
certifications
199 EAC certification
200 Unit approved to Australian code
257 Evaporator sound insulation
266 Victaulic piping connections with welded joints Easy installation
267 Victaulic piping connections with welded joints Easy installation
268 Victaulic piping connections with flanged joints Easy installation
269 Victaulic piping connections with flanged joints Easy installation
The compressor is covered with a thermal
271
insulation layer
230V AC power supply source provided with
284
plug socket and transformer (180 VA, 0,8
Amps)
Control & connections to a Free Cooling
313
Drycooler 09PE or 09VE fitted with option FC 
control box
Specifics documents according Morroco 
327
regulation
Advantages
Easy and high-speed connection by
ethernet line to a building management
system. Allows access to multiple unit
parameters
Reduced maximum power input and
current absorption: power cables and
protection elements can therefore be
downsized
Simple installation: for applications with
cold water at condenser inlet (ex. ground-
source, groundwater-source, superficial 
water-source applications) the signal
permits to control a 2 or 3-way valve to
maintain condenser water temperature
(and so condensing pressure) at
acceptable values
Easy system management, extended
control capabilities of a remote drycooler
Extended remote control capabilities
(Set-point reset, ice storage end, demand
limits, boiler on/off command...)
Enhanced ease of use.
Immediate customer notification of 
refrigerant losses to the atmosphere,
allowing timely corrective actions
Valve replacement and inspection
facilitated without refrigerant loss.
Comforms to European standard  EN378/
BGVD4
Conformance with Swiss regulations
Conformance with Russian regulations
Conformance with Australian regulations
3 dB(A) quiter than standard unit
Prevents air humidity to condensate on the
compressor surface
Permits connection of a laptop or an
electrical device during unit commissioning
or servicing
Easy system managment, Extended
control capabilities to a dryccoler used
in Free Cooling mode
Conformance with Morocco regulations
Use for 30XW/
30XWH range
-0254-P1762
except 30XW
0254-0354
-0254-P1762
-0254-P1762
-0254-P1762
-0254-P1762
-0254-P1762
-0254-P1762
-0254-P1762
-0254-P1762
-0254-P1762
-0254-P1762
-0402-P1762
-0254-P1762
-0254-P1762
-0254-P1762
-0254-P1762
-0254-P1762
-0254-P1762
-0254-P1762
-0254-P1762