4 - PHYSICAL AND ELECTRICAL DATA
■ Standard-efficiency units
30XW--/30XWH
Sound levels - standard unit
Sound power level
(1)
Sound pressure level at 1 m
(2)
Sound levels - standard unit + option 257
Sound power level
(1)
Sound pressure level at 1 m
(2)
Dimensions - standard unit
Length
Width
Height
Operating weight
(4)
Compressors
Circuit A
Circuit B
Refrigerant
(4)
Circuit A
Circuit B
Oil - standard unit
Circuit A
Circuit B
Capacity control
Minimum capacity
(5)
Evaporator
Net water volume
Water connections (Victaulic)
Drain and vent connections (NPT)
Max. water-side operating pressure
Condenser
Net water volume
Water connections (Victaulic)
Drain and vent connections (NPT)
Max. water-side operating pressure
(1) In dB ref=10
-12
W, (A) weighting. Declared dualnumber noise emission values in accordance with ISO 4871 (with an associated uncertainty of +/-3dB(A)). Measured in
accordance with ISO 9614-1 and certified by Eurovent.
(2) In dB ref 20µPa, (A) weighting. Declared dualnumber noise emission values in accordance with ISO 4871 (with an associated uncertainty of +/-3dB(A)). For information,
calculated from the sound power level Lw(A).
(3) Option 257 = Low noise level.
(4) Weight shown is guideline only. Please refer to the unit nameplate.
(5) Minimum unit capacity corresponds to a physical state of the unit and is given for indication only. The actual capacity at this stage depends on operating conditions.
14
dB(A)
dB(A)
(3)
dB(A)
dB(A)
mm
mm
mm
kg
kg
teqCO
2
kg
teqCO
2
l
l
%
l
in
in
kPa
l
in
in
kPa
Eurovent certified values
852
1002
1052
1154
99
102
102
102
82
84
84
84
96
99
99
99
78
80
80
80
2780
4025
4025
4025
1042
1036
1036
1036
1898
1870
1870
1925
3492
5370
5408
5698
Semi-hermetic 06T screw compressors, 50 r/s
1
1
1
1
-
1
1
1
158
85
85
105
226
122
122
150
-
85
85
105
-
122
122
150
36
32
32
32
-
32
32
32
SmartVu
, electronic expansion valves (EXV)
TM
30
30
30
30
Multi-pipe flooded type
98
182
182
205
6
6
6
8
3/8
3/8
3/8
3/8
1000
1000
1000
1000
Multi-pipe flooded type
137
193
193
193
8
8
8
8
3/8
3/8
3/8
3/8
1000
1000
1000
1000
1252
1352
1452
1552
102
102
102
102
83
83
83
83
99
99
99
99
80
80
80
80
4730
4730
4730
4730
1156
1156
1156
1156
2051
2051
2051
2051
7066
7267
7305
7337
1
1
1
1
1
1
1
1
R-134a
120
115
110
105
172
164
157
150
120
115
110
105
172
164
157
150
36
36
36
36
32
36
36
36
15
15
15
30
301
301
301
301
8
8
8
8
3/8
3/8
3/8
3/8
1000
1000
1000
1000
340
340
340
340
8
8
8
8
3/8
3/8
3/8
3/8
1000
1000
1000
1000
1652
1702
102
102
83
83
99
99
80
80
4790
4790
1902
1902
1515
1515
8681
8699
1
1
1
1
195
195
279
279
195
195
279
279
36
36
36
36
30
30
354
354
8
8
3/8
3/8
1000
1000
426
426
8
8
3/8
3/8
1000
1000

Advertisement