Thank you very much for purchasing this Air Conditioner. Please
read this use and installation instructions carefully before installing
and using this appliance and keep this manual for future reference.
migliori offerte di Condizionatori e Deumidificatori
Hisense

Advertisement

Table of Contents
loading

Summary of Contents for Hisense CBBT241AG

  • Page 1 Questo manuale d’istruzione è fornito da trovaprezzi.it. Scopri tutte le offerte per Hisense CBBT241AG o cerca il tuo prodotto tra le migliori offerte di Condizionatori e Deumidificatori Thank you very much for purchasing this Air Conditioner. Please read this use and installation instructions carefully before installing...
  • Page 2: Table Of Contents

    Contents Safety introduction Preparation before use Safety Precautions Identification of parts Indoor unit Outdoor unit Display introduction Maintenance Protection Troubleshooting Installation instructions Installation diagram Select the installation locations Indoor unit installation Outdoor unit installation Air purging Remote controller operating instructions. See"remote controller instructions".
  • Page 3 Safety instructions To guarantee the unit work normally, please read the manual carefully before installation, and try to install strictly according to this manual. Do not let air enter the refrigeration system or discharge refrigerant when moving the air conditioner. Earth the air conditioner properly.
  • Page 4: Preparation Before Use

    Preparation before use Note When charging refrigerant into the system, make sure to charge in liquid state, if the refrigerant of the appliance is R410A.Otherwise, chemical composition of refrigerant (R410A) inside the system may change and thus affect the performance of the air conditioner.
  • Page 5: Safety Precautions

    Safety precautions Symbols in this Use and Care Manual are interpreted as shown below. Be sure not to do. Grounding is essential. Warning: Incorrect handling could Pay attention to such a situation. cause a serious hazard, such as death, serious injury, etc. Use correct power supply in accordance with the rating plate requirement.
  • Page 6: Identification Of Parts

    Identification of parts Indoor unit Front Panel Air Intake Display Panel Air Outlet Vertical Adjustment Louver Horizontal Adjustment Louver Air Filter Remote Controller Air Intake Outdoor unit Pipes and Power Connection Cord Drain Hose Note: Condensate water drains at COOLING or DRY operation. Air Outlet The figures in this manual are based on the external view of a standard model.
  • Page 7: Display Introduction

    Display introduction Temperature indicator Display set temperature. It shows FC after 200 hours of usage as reminder to clean the filter. After filter cleaning press the filter reset button located on the indoor unit behind the front panel in order to reset the display.(optional) Running indicator It lights up when the AC is running.
  • Page 8 Display introduction VT series /DG(Right side) series SE series The symbols may be different from these models, but the functions are similar.
  • Page 9 Display introduction UL series Comp. Timer Sleep UQ series UP series Sleep Comp. Timer The symbols may be different from these models, but the functions are similar.
  • Page 10 Display introduction NS/DE series NT series SH series VQ/TE/TF/TK/DA/DG(Middle)/DH/SG series The symbols may be different from these models, but the functions are similar.
  • Page 11 Display introduction VM series NM/DF series NK series TA/TC series The symbols may be different from these models, but the functions are similar.
  • Page 12 Display introduction TJ series TJ (hidden display) series TL series VC series Comp. Timer Sleep The symbols may be different from these models, but the functions are similar.
  • Page 13 Display introduction SA/TD/TG/DB/DC series SC series FOR THE WLP TJ SERIES Emergency button To let the AC run or stop by pressing the button. ON/OFF Filter reset button To reset filter clean indicator by pressing the button. Emergency button To let the AC run or stop by pressing the button. ON/OFF The symbols may be different from these models, but the functions are similar.
  • Page 14: Maintenance

    Maintenance Front panel maintenance Air filter maintenance Cut off the power supply It is necessary to clean the air filter after using it for about 100 hours. Turn off the appliance first before disconnecting Clean it as follows: from power supply. Stop the appliance and remove the air filter.
  • Page 15: Protection

    Protection Operating condition Noise pollution The protective device maybe trip and stop Install the air conditioner at a place that the appliance in the cases listed below. can bear its weight in order to operate more quietly. Outdoor air temperature is over 24 C Install the outdoor unit at a place where HEATING Outdoor air temperature is below -7 C...
  • Page 16: Troubleshooting

    Troubleshooting The following cases may not always be a malfunction, please check it before asking for service. Trouble Analysis If the protector trip or fuse is blown. Please wait for 3 minutes and start again, Does not run protector device may be preventing unit to work. If batteries in the remote controller exhausted.
  • Page 17: Installation Instructions

    Installation instructions Installation diagram Distance from ceiling should be over 200 mm Distance from wall should be over 50mm Distance from the wall should be over 50mm Distance from floor should be over 2500mm. Air intake distance from the wall should be over 250mm Air intake distance from the wall should be...
  • Page 18: Select The Installation Locations

    Installation instructions Select the installation location Location for Installing Indoor Unit Where there is no obstacle near the air outlet and air can be easily blown to every corner. Indoor unit Where piping and wall hole can be easily arranged. Keep the required space from the unit to the ceiling and wall according to the installation diagram on previous page.
  • Page 19: Indoor Unit Installation

    Installation instructions Indoor unit installation 1. Installing the Mounting Plate Decide an installing location for the mounting plate according to the indoor unit location and piping direction. Keep the mounting plate horizontally with a horizontal ruler or dropping line. Drill holes of 32mm in depth on the wall for fixing the plate. Insert the plastic plugs to the hole, fix the mounting plate with tapping screws.
  • Page 20 Installation instructions Piping Joints Thermal Insulation: Wrap the piping joints with thermal insulation materials and then wrap with a vinyl tape. wrapped with vinyl type Thermal insulation Piping Thermal Insulation: Large pipe a. Place the drain hose under the piping. Thermal insulation tube b.
  • Page 21 Installation instructions 4. Connecting of the Cable Front panel Terminal (inside) Indoor Unit Connect the power connecting cord to the indoor unit by connecting the wires to the terminals on the control board individually in accordance with the outdoor unit Cabinet connection.
  • Page 22 Installation instructions Wiring Diagram Make sure that the color of wires of the outdoor unit and the terminal No. are the same as those of the indoor unit. 5K,7K,8K,9K,10K,12K,14K,15K,18K,22K,24K,30K Model COOLING ONLY HEAT PUMP HEAT PUMP Indoor unit Indoor unit Indoor unit Indoor unit Outdoor unit...
  • Page 23 Installation instructions 18K,24K,30K Model Indoor unit Outdoor unit Terminal Terminal Black Black Brown Brown Blue Blue Power connecting cord Yellow/Green Yellow/Green For these models, the power supply are connected from indoor unit. 28K.30K.36K Model Outdoor unit Indoor unit Terminal Terminal Brown Power connecting cord Terminal...
  • Page 24: Outdoor Unit Installation

    Installation instructions Outdoor unit installation 1.Install Drain Port and Drain Hose (for heat-pump model only) Rubber pad (optional) Place under the leg pedestal The condensate drains from the outdoor unit when the unit operates in heating mode. In order not to disturb your neighbor and protect the environment, install a drain port and a drain hose to direct the condensate water.
  • Page 25 Installation instructions How to Purge Air Tubes: (1). Unscrew and remove caps from 2 and 3-way valves. (2). Unscrew and remove cap from service valve. (3). Connect vacuum pump flexible hose to the service valve. (4). Start vacuum pump for 10-15 minutes until reaching a vacuum of 10 mm Hg absolutes. (5).
  • Page 26 Version No.1826846-02...