Ventilation; Specifications For The Plumbed Water Connection - Miele KF2811SF Operating And Installation Instructions

Fridge-freezer combination
Hide thumbs Also See for KF2811SF:
Table of Contents

Advertisement

Installation information

Ventilation

WARNING! Risk of fire!
Operation of the appliance is limited.
Keep the required ventilation gaps
free from obstruction.
Noncompliance with the specified di-
mensions for the ventilation grille will
cause the compressor to turn on
more often and run for longer peri-
ods.
This causes increased energy con-
sumption and an increased com-
pressor operating temperature,
which can result in damage to the
compressor.
Do not block the ventilation gaps.
They must also be cleaned on a reg-
ular basis to remove dust.
18
Specifications for the plumbed water
connection
– The machine may only be connected
to the plumbed water connection by
qualified technicians.
– Connection to the household water
supply must comply with the applica-
ble regulations in the country in
which the machine is being installed.
All units and systems used to supply
water to the machine must also com-
ply with the applicable regulations in
the respective country.
– The water quality must comply with
the requirements for drinking water in
the country in which the machine is
being operated.
– The water pressure must be between
29 and 116 psi (2 and 8 bar).
– The appliance is only suitable for
connection to a cold water line.
– The appliance may only be con-
nected directly to a fresh water sup-
ply to ensure that water is circulated
in the cold water line.
– A shut-off valve must be provided
between the water line and the water
supply of the building to ensure that
the water supply can be cut off if
necessary.
– Make sure that the shut-off valve is
still accessible after the appliance
has been installed.