GREISINGER GMH 3201 Operating Manual

GREISINGER GMH 3201 Operating Manual

Quick-response thermometer

Advertisement

Quick Links

H76.0.25.6C-01
as of version 4.0
Please carefully read these instructions
before use!
Please consider the safety instructions!
Please keep for future reference!
GHM GROUP - Greisinger
GHM Messtechnik GmbH | Hans-Sachs-Str. 26 | 93128 Regenstauf | GERMANY
Tel.: +49 9402 9383-0 |
Quick-Response Thermometer
info@greisinger.de
| www.greisinger.de
Operating manual
GMH 3201
WEEE-Reg.-Nr. DE 93889386

Advertisement

Table of Contents
loading

Summary of Contents for GREISINGER GMH 3201

  • Page 1  Please consider the safety instructions!  WEEE-Reg.-Nr. DE 93889386 Please keep for future reference! GHM GROUP - Greisinger GHM Messtechnik GmbH | Hans-Sachs-Str. 26 | 93128 Regenstauf | GERMANY Tel.: +49 9402 9383-0 | info@greisinger.de | www.greisinger.de...
  • Page 2: Table Of Contents

    H76.0.25.6C-01 Operating Manual GMH 3201 page 2 of 12 _____________________________________________________ _____________________________________________________________________________ Index 1 GENERAL NOTE ....................... 2 2 SAFETY ..........................3 2.1 I ........................3 NTENDED 2.2 S .................... 3 AFETY SIGNS AND SYMBOLS 2.3 S ......................4 AFETY GUIDELINES 3 PRODUCT SPECIFICATION ...................
  • Page 3: Safety

    H76.0.25.6C-01 Operating Manual GMH 3201 page 3 of 12 _____________________________________________________ _____________________________________________________________________________ 2 Safety 2.1 Intended Use This device is designed for temperature measurement. You can plug in a thermocouple sensor with Miniature-DIN-plug. The device features a lot of useful features as for example hold, correction factor for surface measurement, interface etc.
  • Page 4: Safety Guidelines

    H76.0.25.6C-01 Operating Manual GMH 3201 page 4 of 12 _____________________________________________________ _____________________________________________________________________________ 2.3 Safety guidelines This device has been designed and tested in accordance with the safety regulations for electronic devices. However, its trouble-free operation and reliability cannot be guaranteed unless the standard safety measures and special safety advises given in this manual will be adhered to when using the device.
  • Page 5: Product Specification

    H76.0.25.6C-01 Operating Manual GMH 3201 page 5 of 12 _____________________________________________________ _____________________________________________________________________________ Product Specification 3.1 Scope of delivery The scope of supply includes:  Device with battery  Operating manual 3.2 Operation and maintenance advice  Battery operation: If ‘bAt’ is shown in the lower display the battery has been used up and needs to be replaced.
  • Page 6: Handling

    H76.0.25.6C-01 Operating Manual GMH 3201 page 6 of 12 _____________________________________________________ _____________________________________________________________________________ 4 Handling 4.1 Display Main display: measuring value Arrows show display options Secondary display: display of min/max, hold corr: appears if offset- , scale correction or correction for surface measurement is <> state of delivery.
  • Page 7: Pop-Up Clip

    H76.0.25.6C-01 Operating Manual GMH 3201 page 7 of 12 _____________________________________________________ _____________________________________________________________________________ 4.4 Pop-up clip Handling: • Pull at label “open” in order to swing open the pop-up clip. • Pull at label “open” again to swing open the pop-up clip further.
  • Page 8: Device Configuration

    H76.0.25.6C-01 Operating Manual GMH 3201 page 8 of 12 _____________________________________________________ _____________________________________________________________________________ 6 Device Configuration To change device settings, press Set (key 4) for 2 seconds. This will call the configuration menu. The parameters can be changed with  (key 2) or  (key 5).
  • Page 9: Adjustment

    H76.0.25.6C-01 Operating Manual GMH 3201 page 9 of 12 _____________________________________________________ _____________________________________________________________________________ Adjustment 8.1 Zero Displacement A zero displacement can be carried out for the measured value: value displayed = value measured - offset Standard setting: 'off' = 0.0°, i.e. no zero displacement will be carried out. Together with the scale correction (see below) this factor is mainly used to compensate for sensor deviations.
  • Page 10: Fault And System Messages

    H76.0.25.6C-01 Operating Manual GMH 3201 page 10 of 12 _____________________________________________________ _____________________________________________________________________________ 9 Fault and System Messages Display Meaning What to do? Low battery power, device will only Replace battery continue operation for a short period of time Battery empty Replace battery...
  • Page 11: Reshipment And Disposal

    H76.0.25.6C-01 Operating Manual GMH 3201 page 11 of 12 _____________________________________________________ _____________________________________________________________________________ 10 Reshipment and disposal 10.1 Reshipment All devices returned to the manufacturer have to be free of any residual of measuring media and other hazardous substances. Measuring residuals at housing or sensor may be a risk for persons or...
  • Page 12: Specification

    H76.0.25.6C-01 Operating Manual GMH 3201 page 12 of 12 _____________________________________________________ _____________________________________________________________________________ 11 Specification Thermocouples: K (NiCr-Ni) Resolution: 0.1°C or 1°C 0.1°F or 1°F Measuring range: -220.0 ... +1372.0°C -364.0 ... +1999.9°F Accuracy: (for thermocouples acc. to DIN EN 60584) ±1digit (at nominal temperature ±...