H76.0.25.6C-01 Operating Manual GMH 3201 page 3 of 12 _____________________________________________________ _____________________________________________________________________________ 2 Safety 2.1 Intended Use This device is designed for temperature measurement. You can plug in a thermocouple sensor with Miniature-DIN-plug. The device features a lot of useful features as for example hold, correction factor for surface measurement, interface etc.
H76.0.25.6C-01 Operating Manual GMH 3201 page 4 of 12 _____________________________________________________ _____________________________________________________________________________ 2.3 Safety guidelines This device has been designed and tested in accordance with the safety regulations for electronic devices. However, its trouble-free operation and reliability cannot be guaranteed unless the standard safety measures and special safety advises given in this manual will be adhered to when using the device.
H76.0.25.6C-01 Operating Manual GMH 3201 page 5 of 12 _____________________________________________________ _____________________________________________________________________________ Product Specification 3.1 Scope of delivery The scope of supply includes: Device with battery Operating manual 3.2 Operation and maintenance advice Battery operation: If ‘bAt’ is shown in the lower display the battery has been used up and needs to be replaced.
H76.0.25.6C-01 Operating Manual GMH 3201 page 6 of 12 _____________________________________________________ _____________________________________________________________________________ 4 Handling 4.1 Display Main display: measuring value Arrows show display options Secondary display: display of min/max, hold corr: appears if offset- , scale correction or correction for surface measurement is <> state of delivery.
H76.0.25.6C-01 Operating Manual GMH 3201 page 7 of 12 _____________________________________________________ _____________________________________________________________________________ 4.4 Pop-up clip Handling: • Pull at label “open” in order to swing open the pop-up clip. • Pull at label “open” again to swing open the pop-up clip further.
H76.0.25.6C-01 Operating Manual GMH 3201 page 8 of 12 _____________________________________________________ _____________________________________________________________________________ 6 Device Configuration To change device settings, press Set (key 4) for 2 seconds. This will call the configuration menu. The parameters can be changed with (key 2) or (key 5).
H76.0.25.6C-01 Operating Manual GMH 3201 page 9 of 12 _____________________________________________________ _____________________________________________________________________________ Adjustment 8.1 Zero Displacement A zero displacement can be carried out for the measured value: value displayed = value measured - offset Standard setting: 'off' = 0.0°, i.e. no zero displacement will be carried out. Together with the scale correction (see below) this factor is mainly used to compensate for sensor deviations.
H76.0.25.6C-01 Operating Manual GMH 3201 page 10 of 12 _____________________________________________________ _____________________________________________________________________________ 9 Fault and System Messages Display Meaning What to do? Low battery power, device will only Replace battery continue operation for a short period of time Battery empty Replace battery...
H76.0.25.6C-01 Operating Manual GMH 3201 page 11 of 12 _____________________________________________________ _____________________________________________________________________________ 10 Reshipment and disposal 10.1 Reshipment All devices returned to the manufacturer have to be free of any residual of measuring media and other hazardous substances. Measuring residuals at housing or sensor may be a risk for persons or...