Siemens SIMATIC NET RUGGEDCOM RS950G Equipment Manual page 24

Rugged ethernet switches
Hide thumbs Also See for SIMATIC NET RUGGEDCOM RS950G:
Table of Contents

Advertisement

2.
3.
4.
RUGGEDCOM RS950G
Equipment Manual, 10/2023, C79000-G8976-1037-08
Braided Ground Cable
4
Figure 2.6
Terminal Block Wiring - Dual DC Power Supply Inputs
Connect the negative wire from the power source to the negative terminal on
the terminal block.
Using a braided wire or other appropriate grounding wire, connect the surge
ground terminal to the chassis ground connection. The surge ground terminal
is used as the ground conductor for all surge and transient suppression circuitry
internal to the unit.
Connect the ground terminal on the power source to the chassis ground
terminal on the device.
Installing the Device
2.5.2 Connecting Low DC Power
15