Appendix
Fault
Product does not
After three successive failed ignition
start up:
attempts, the system switches to fault
mode (fault code: F.28).
– No hot water
– Heating does
not heat up
Hot water gener-
The external controller is not set cor-
ation functioning
rectly.
correctly; heating
does not start up.
16
Cause
Operating instructions EASICOM 0020238425_01
Measure
Press the
button. The product
carries out a new ignition attempt.
If the ignition problem is not rec-
tified after three fault clearance
attempts, contact a competent
person.
Set the external controller cor-
rectly (→ Controller operating in-
structions).