7700 MultiFrame Manual
7751SRG-HD HD-SDI Tri-Level Sync Generator
4.
STATUS LEDS
4.1.
MODULE STATUS LEDS
The location of the status LEDs is shown in Figure 6-1.
MODULE OK:
This Green LED will be On when the module is operating properly.
LOCAL FAULT:
This Red LED will blink on and off if the microprocessor is not running. The LED will
be on solid when there is a fault in the module power supply.
SIGNAL PRESENT: This Green LED will be On when there is a valid genlock signal present at the
module genlock input.
This LED does not necessarily indicate that the genlock signal is the correct frame
rate for the selected sync output format.
required for the selected output video format, but a 50 Hz signal is present at the
genlock input, the SIGNAL PRESENT LED will be On. In this case, the output video
will NOT be properly referenced but will constantly try to re-sync to the genlock
frame reference.
DIVISOR:
This Green LED will be On when the Slave Reference generator is operating with
the 1/1.001 Divisor enabled. This mode is selected when DIP switch 1 in On.
Page - 4
For example, if a 59.94 Hz signal is
Revision 1.5.2