Assessment According To Iec 62061 - Siemens S7-1500F Manual

Safe detection with inductive, clocking sensors up to sil 3 / pl d
Table of Contents

Advertisement

3 Useful information
3.2.4

Assessment according to IEC 62061

An assessment according to IEC 62061 was performed with the Safety Evaluation
in the TIA Selection Tool (SE@TST): You can find a link to the Safety Evaluation in
the TIA Selection Tool on the internet at \11\.
3.2.4.1
Safety function SF1
The individual subsystems of the safety function are explained below.
"Detection" assessment SF1
For the SF1, the GM505S inductive, clocking sensor represents the "Detection"
subsystem.
The safety-related parameters of the component are provided by the manufacturer.
Table 3-9 Result of "Detection" SF1 subsystem
Inductive, clocking sensor
Total
"Evaluation" assessment SF1
In the "Evaluation" subsystem, the fail-safe controller CPU 1516F and the
associated F-DI module of the ET 200SP are involved in evaluating the sensor.
Table 3-10 Result of "Detection" SF1
CPU 1516F-3 PN/DP
ET 200MP, F-DI 16x24VDC
Hierarchy levels: Single-channel
Total
Result of the assessment according to IEC 62061 SF1
Table 3-11 Result of the assessment SF1
Detection
Evaluate
Total
Inductive clocking sensor
Entry ID: 109818998,
V1.0,
Component
Component
Subsystem
1.00 ∙ 10
3.00 ∙ 10
1.30 ∙ 10
05/2023
PFH
SIL
D
1.00 ∙ 10
-8
SIL 3
ifm electronic gmbh
1.00 ∙ 10
-8
SIL 3
PFH
SIL
D
2.00 ∙ 10
-9
SIL 3
Siemens AG
1.00 ∙ 10
-9
SIL 3
3.00 ∙ 10
-9
SIL 3
PFH
D
-8
SIL 3
-9
SIL 3
-8
SIL 3
Specification
Specification
Achieved SIL
27