Summary of Contents for Endress+Hauser Micropilot FMR60B PROFIBUS PA
Page 1
Products Solutions Services TI01693F/00/EN/01.23-00 71627283 2023-09-01 Technical Information Micropilot FMR60B PROFIBUS PA Free space radar Level measurement in liquids Application • Continuous, non-contact level measurement of liquids, pastes and sludges • Process connections: Thread or mounting bracket • Maximum measuring range: 50 m (164 ft) •...
Micropilot FMR60B PROFIBUS PA Important document information Symbols Safety symbols DANGER This symbol alerts you to a dangerous situation. Failure to avoid this situation will result in serious or fatal injury. WARNING This symbol alerts you to a dangerous situation. Failure to avoid this situation can result in serious or fatal injury.
Micropilot FMR60B PROFIBUS PA Graphic conventions • Installation, explosion and electrical connection drawings are presented in simplified format • Devices, assemblies, components and dimensional drawings are presented in reduced-line format • Dimensional drawings are not to-scale representations; the dimensions indicated are rounded off to 2 decimal places •...
Micropilot FMR60B PROFIBUS PA D = (c ∆t) / 2 where c is the speed of propagation of the wave. In summary, D can be calculated from the measured difference frequency Δf. D is then used to determine the content of the tank or silo.
Page 6
Micropilot FMR60B PROFIBUS PA 100% A0051658 3 Usable measuring range Length of antenna + 10 mm (0.4 in) Usable measuring range 50 to 80 mm (1.97 to 3.15 in); medium εr < 2 Vessel height Reference point of measurement, varies depending on the antenna system For further information on the reference point, see →...
Page 7
To measure absorbing gases, either use a guided radar, measuring devices with another measuring frequency or another measuring principle. If measurements must be performed in one of these media, please contact Endress+Hauser. For the dielectric constants (DC values) of many media commonly used in industry, please refer •...
Page 8
Micropilot FMR60B PROFIBUS PA Integrated antenna, PEEK, 40 mm (1.5 in) in storage vessel Media group Measuring range A0 (ε 1.2 to 1.4) 3 m (10 ft) A (ε 1.4 to 1.9) 6 m (20 ft) B (ε 1.9 to 4) 11 m (36 ft) C (ε...
Page 9
Micropilot FMR60B PROFIBUS PA Integrated antenna, PEEK, 40 mm (1.5 in) in buffer vessel Media group Measuring range A0 (ε 1.2 to 1.4) 1.5 m (5 ft) A (ε 1.4 to 1.9) 3 m (10 ft) B (ε 1.9 to 4) 6 m (20 ft) C (ε...
Page 10
Micropilot FMR60B PROFIBUS PA Integrated antenna, PEEK, 20 mm (0.75 in) in vessel with agitator Media group Measuring range A (ε 1.4 to 1.9) 1 m (3.3 ft) B (ε 1.9 to 4) 1.5 m (5 ft) C (ε 4 to 10) 3 m (10 ft) D (ε...
Micropilot FMR60B PROFIBUS PA PTFE Drip-off antenna, 50 mm (2 in) in vessel with agitator Media group Measuring range A0 (ε 1.2 to 1.4) 2 m (7 ft) A (ε 1.4 to 1.9) 4 m (13 ft) B (ε 1.9 to 4) 7 m (23 ft) C (ε...
Micropilot FMR60B PROFIBUS PA Protocol-specific data PROFIBUS PA Manufacturer ID: 17 (0x11) Ident number: 0x1568 or 0x9700 Profile version: 3.02 GSD file and version Information and files available at: • www.endress.com On the product page for the device: Documents/Software → Device drivers •...
Micropilot FMR60B PROFIBUS PA Power supply Terminal assignment Single compartment housing A0042594 4 Connection terminals and ground terminal in the connection compartment Positive terminal Negative terminal Internal ground terminal Dual compartment housing A0042803 5 Connection terminals and ground terminal in the connection compartment...
Micropilot FMR60B PROFIBUS PA Dual compartment housing, L-form A0045842 6 Connection terminals and ground terminal in the connection compartment Positive terminal Negative terminal Internal ground terminal Terminals • Supply voltage and internal ground terminal: 0.5 to 2.5 mm (20 to 14 AWG) •...
Micropilot FMR60B PROFIBUS PA Nominal current 14 mA Failure current FDE (Fault 0 mA Disconnection Electronic) • Use only suitable and certified Profibus PA components (e.g. DP/PA segment coupler) for the power supply • FISCO/FNICO-compliant according to IEC 60079-27 • The supply is not polarity-dependent...
Micropilot FMR60B PROFIBUS PA The type of cable entry depends on the device version ordered. Always route connecting cables downwards so that moisture cannot penetrate the connection compartment. If necessary, create a drip loop or use a weather protection cover.
Micropilot FMR60B PROFIBUS PA Maximum measured error Reference accuracy Accuracy The accuracy is the sum of the non-linearity, non-repeatability and hysteresis. • Measuring distance up to 0.8 m (2.62 ft): max. ±4 mm (±0.16 in) • Measuring distance > 0.8 m (2.62 ft): ±1 mm (±0.04 in) Non-repeatability Non-repeatability is already included in the accuracy.
Micropilot FMR60B PROFIBUS PA error for some typical gases/vapors (with regard to the distance, a positive value means that an excessively large distance is measured): Measured error for some typical gases/vapors Gas phase Temperature Pressure 1 bar (14.5 psi) 10 bar (145 psi)
Micropilot FMR60B PROFIBUS PA Orientation Internal vessel fittings α A0031777 Avoid internal fittings (point level switches, temperature sensors, struts, vacuum rings, heating coils, baffles etc.) inside the signal beam. Pay attention to the beam angle α. Avoiding interference echoes A0031813 Metal deflector plates, installed at an angle to scatter the radar signals, help prevent interference echoes.
Micropilot FMR60B PROFIBUS PA Radial alignment of the antenna Based on the directional characteristic, radial alignment of the antenna is not necessary. Installation instructions Encapsulated antenna, PVDF 40 mm (1.57 in) Information about the mounting nozzle The maximum nozzle length H depends on the nozzle diameter D.
Micropilot FMR60B PROFIBUS PA Maximum nozzle length H as a function of the nozzle diameter D D 40 to 50 mm (1.6 to 2 in) 200 mm (8 in) 50 to 80 mm (2 to 3.2 in) 300 mm (12 in) 80 to 100 mm (3.2 to 4 in)
Page 22
Micropilot FMR60B PROFIBUS PA α α A0031824 9 Relationship between beam angle α, distance D and beamwidth diameter W The beamwidth diameter W depends on the beam angle α and the distance D. Encapsulated antenna, PVDF 40 mm / 1-1/2", α = 8 °...
Micropilot FMR60B PROFIBUS PA The material thickness can be a full multiple of the optimum thickness (table); it is important to note, however, that the microwave transparency decreases significantly with increasing material thickness. Optimum material thickness Material Optimum material thickness PE;...
Page 25
Micropilot FMR60B PROFIBUS PA Plastic housing Plastic housing; process temperature –20 to +150 °C (–4 to +302 °F) A0032024 10 Plastic housing; process temperature –20 to +150 °C (–4 to +302 °F) = T : –20 °C (–4 °F) | T : +76 °C (+169 °F) = T...
Page 26
Micropilot FMR60B PROFIBUS PA Restriction to a process temperature of 0 to +200 °C (+32 to +392 °F) with CSA C/US approval and plastic housing A0048826 13 Plastic housing; process temperature 0 to +200 °C (+32 to +392 °F) with CSA C/US approval = T...
Page 27
Micropilot FMR60B PROFIBUS PA Plastic housing; process temperature –40 to +130 °C (–40 to +266 °F) A0032024 16 Plastic housing; process temperature –40 to +130 °C (–40 to +266 °F) = T : –40 °C (–40 °F) | T : +76 °C (+169 °F) = T...
Page 28
Micropilot FMR60B PROFIBUS PA Restriction to a process temperature of 0 to +150 °C (+32 to +302 °F) with CSA C/US approval and plastic housing A0048826 19 Plastic housing; process temperature 0 to +150 °C (+32 to +302 °F) with CSA C/US approval = T...
Page 29
Micropilot FMR60B PROFIBUS PA Aluminum housing, coated Aluminum housing; process temperature –20 to +150 °C (–4 to +302 °F) A0032024 22 Aluminum housing, coated; process temperature –20 to +150 °C (–4 to +302 °F) = T : –20 °C (–4 °F) | T : +79 °C (+174 °F)
Page 30
Micropilot FMR60B PROFIBUS PA Aluminum housing; process temperature –40 to +130 °C (–40 to +266 °F) A0032024 25 Aluminum housing, coated; process temperature –40 to +130 °C (–40 to +266 °F) = T : –40 °C (–40 °F) | T : +79 °C (+174 °F) = T...
Page 31
Micropilot FMR60B PROFIBUS PA 316L housing 316L housing; process temperature –20 to +150 °C (–4 to +302 °F) A0032024 28 316L housing; process temperature –20 to +150 °C (–4 to +302 °F) = T : –20 °C (–4 °F) | T : +77 °C (+171 °F) = T...
Page 32
Micropilot FMR60B PROFIBUS PA 316L housing; process temperature –40 to +130 °C (–40 to +266 °F) A0032024 31 316L housing; process temperature –40 to +130 °C (–40 to +266 °F) = T : –40 °C (–40 °F) | T : +77 °C (+171 °F) = T...
Page 33
Micropilot FMR60B PROFIBUS PA 316L housing, hygiene 316L housing, hygiene; process temperature –20 to +150 °C (–4 to +302 °F) A0032024 34 316L housing, hygiene; process temperature –20 to +150 °C (–4 to +302 °F) = T : –20 °C (–4 °F) | T : +76 °C (+169 °F)
Micropilot FMR60B PROFIBUS PA 316L housing, hygiene; process temperature –40 to +130 °C (–40 to +266 °F) A0032024 37 316L housing, hygiene; process temperature –40 to +130 °C (–40 to +266 °F) = T : –40 °C (–40 °F) | T : +76 °C (+169 °F) = T...
Micropilot FMR60B PROFIBUS PA Degree of protection Test as per IEC 60529 and NEMA 250-2014 Housing IP66/68, NEMA TYPE 4X/6P IP68 test condition: 1.83 m under water for 24 hours. Cable entries • Gland M20, plastic, IP66/68 NEMA TYPE 4X/6P •...
Page 36
Micropilot FMR60B PROFIBUS PA Encapsulated antenna, PVDF, 40 mm (1.5 in) Process connection thread 1-½" Seal Process pressure range PVDF encapsulated –40 to +80 °C –1 to 3 bar (–14.5 to 43.5 psi) (–40 to +176 °F) PVDF encapsulated –40 to +130 °C –1 to 3 bar (–14.5 to 43.5 psi)
The pressure range may be further restricted in the event of a CRN approval. Dielectric constant For liquids ε ≥ 1.2 Contact Endress+Hauser for applications with lower dielectric constants than indicated. Mechanical construction Dimensions The dimensions of the individual components must be added together for the total dimensions. Endress+Hauser...
Page 38
Micropilot FMR60B PROFIBUS PA Single compartment housing, plastic 94 (3.7) 107.5 (4.23) A0048768 40 Dimensions of single compartment housing, plastic (PBT). Unit of measurement mm (in) Height with cover with plastic viewing window Cover without viewing window Aluminum single compartment housing 101 (3.98)
Page 39
Micropilot FMR60B PROFIBUS PA 316L single compartment housing, hygiene 92 (3.62) 123 (4.84) A0050364 42 Dimensions of 316L single compartment housing, hygiene. Unit of measurement mm (in) Height with cover with glass viewing window (dust Ex) Height with cover with plastic viewing window...
Page 40
Micropilot FMR60B PROFIBUS PA Aluminum dual compartment housing 132 (5.2) 121 (4.76) 115 (4.53) 118 (4.65) 64 (2.52) 54 (2.13) 78 (3.07) 143 (5.63) A0038377 43 Dimensions of dual compartment housing. Unit of measurement mm (in) Height with cover with glass viewing window (devices for Ex d/XP, Dust-Ex)
Page 41
Micropilot FMR60B PROFIBUS PA Dual compartment housing, L-shaped, aluminum or 316 L 110 (4.33) 101 (3.98) 140 (5.51) 138 (5.43) A0038381 44 Dimensions of L-shaped dual compartment housing. Unit of measurement mm (in) Height with cover comprising glass sight glass (devices for Ex d/XP, dust Ex)
Page 42
Micropilot FMR60B PROFIBUS PA Encapsulated antenna, PVDF, 40 mm (1.5 in), process connection UNI flange 50 mm 43.7 (1.72) A0048829 46 Dimensions of encapsulated antenna, PVDF, 40 mm (1.5 in), process connection UNI flange. Unit of measurement mm (in)
Page 43
Micropilot FMR60B PROFIBUS PA UNI flange 4"/DN100/100A 20 (0.79) A0048848 48 Dimensions of UNI flange 4"/DN100/100A. Unit of measurement mm (in) Suitable for ASME B16.5, 4" 150lbs / EN1092-1; DN100 PN16 / JIS B2220; 10K 100A Material: PP, weight 0.70 kg (1.54 lb) UNI flange 6"/DN150/150A...
Page 44
Micropilot FMR60B PROFIBUS PA Drip-off antenna 50 mm (2 in), threaded process connection 55 mm 42.5 (1.67) A0046479 50 Dimensions of Drip-off antenna 50 mm (2 in), threaded process connection. Unit of measurement mm (in) Process temperature version ≤150 °C (302 °F) Process temperature version ≤200 °C (392 °F)
Page 45
Micropilot FMR60B PROFIBUS PA Drip-off antenna 50 mm (2 in), UNI flange process connection 42.5 (1.67) A0046480 51 Dimensions of Drip-off antenna 50 mm (2 in), UNI flange process connection. Unit of measurement mm (in) Process temperature version ≤150 °C (302 °F) Process temperature version ≤200 °C (392 °F)
Page 46
Micropilot FMR60B PROFIBUS PA UNI flange 4"/DN100/100A 20 (0.79) A0048848 53 Dimensions of UNI flange 4"/DN100/100A. Unit of measurement mm (in) Suitable for ASME B16.5, 4" 150lbs / EN1092-1; DN100 PN16 / JIS B2220; 10K 100A Material: • PP, weight 0.70 kg (1.54 lb) •...
Page 47
Micropilot FMR60B PROFIBUS PA Integrated antenna, PEEK, 20 mm (0.75 in) 36 mm 23.8 (0.94) 32.2 (1.27) A0046481 55 Dimensions; integrated antenna, PEEK, 20 mm (0.75 in); process connection, thread 3/4". Unit of measurement mm (in) Process temperature version ≤150 °C (302 °F) Process temperature version ≤200 °C (392 °F)
Micropilot FMR60B PROFIBUS PA Integrated antenna, PEEK, 40 mm (1.5 in) 42.5 (1.67) 54.8 (2.18) A0046482 56 Dimensions; integrated antenna, PEEK, 40 mm (1.5 in); process connection, thread 1-1/2". Unit of measurement mm (in) Process temperature version ≤150 °C (302 °F) Process temperature version ≤200 °C (392 °F)
Micropilot FMR60B PROFIBUS PA Materials Materials not in contact with process Plastic housing • Housing: PBT/PC • Dummy cover: PBT/PC • Cover with window: PBT/PC and PC • Cover seal: EPDM • Potential equalization: 316L • Seal under potential equalization: EPDM •...
Page 50
Micropilot FMR60B PROFIBUS PA Materials in contact with the medium Encapsulated antenna, PVDF, 40 mm (1.5 in) A0046602 57 Material; encapsulated antenna, PVDF, 40 mm (1.5 in) Antenna, PVDF Threaded process connection, PVDF Housing adapter, PBT-GF30 (dust ignition-proof: 304/ 1.4301)
Page 51
Micropilot FMR60B PROFIBUS PA Integrated antenna, PEEK, 20 mm (0.75 in) A0046605 59 Material; integrated antenna, PEEK, 20 mm (0.75 in) Antenna: PEEK, seal material can be selected (order option) Process connection: 316L / 1.4404 Housing adapter: 316L / 1.4404 Integrated antenna, PEEK, 40 mm (1.5 in)
Micropilot FMR60B PROFIBUS PA Display and user interface Operation concept Operator-oriented menu structure for user-specific tasks • User navigation • Diagnosis • Application • System Quick and safe commissioning • Interactive wizard with graphical interface for guided commissioning in FieldCare, DeviceCare or DTM and PDM-based tools from third-party users or SmartBlue •...
Page 53
Micropilot FMR60B PROFIBUS PA A0043059 61 Segment display without keys A0039284 62 Graphic display Optical operating keys Permitted ambient temperature for the display: –20 to +70 °C (–4 to +158 °F) The readability of the display may be impaired at temperatures outside the temperature range.
Via service interface (CDI) A0039148 Computer with FieldCare/DeviceCare operating tool Commubox FXA291 Service interface (CDI) of the measuring device (= Endress+Hauser Common Data Interface) Operation via Bluetooth® wireless technology (optional) Prerequisite • Measuring device with Bluetooth display • Smartphone or tablet with SmartBlue app or PC with DeviceCare, version 1.07.00 and higher, or FieldXpert SMT70 The connection has a range of up to 25 m (82 ft).
Micropilot FMR60B PROFIBUS PA Supported operating tools Smartphone or tablet with Endress+Hauser SmartBlue (app), DeviceCare, version 1.07.00 and higher, FieldCare, DTM, and PDM. Certificates and approvals Current certificates and approvals for the product are available at www.endress.com on the relevant product page: Select the product using the filters and search field.
Micropilot FMR60B PROFIBUS PA The devices are approved for unrestricted use inside and outside closed containers in countries of the EU and the EFTA. As a prerequisite, the countries must have already implemented this standard. The standard is already implemented in the following countries:...
Micropilot FMR60B PROFIBUS PA This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
• Automatic verification of exclusion criteria • Automatic creation of the order code and its breakdown in PDF or Excel output format • Ability to order directly in the Endress+Hauser Online Shop Calibration Factory calibration certificate The calibration points are spread evenly over the measuring range (0 to 100 %).
Micropilot FMR60B PROFIBUS PA Measuring range restrictions The following restrictions must be considered when selecting E and F: • Minimum distance between reference point R and 100% mark A ≥ 400 mm (16 in) • Minimum span F ≥ 45 mm (1.77 in) • Maximum value for Empty calibration E ≥ 450 mm (17.72 in) (maximum 30 m (98 ft))
Condition Monitoring system and the in-situ verification of devices in the application. The application package can be ordered together with the device or can be activated subsequently with an activation code. Detailed information on the order code is available via the Endress+Hauser website www.endress.com...
Micropilot FMR60B PROFIBUS PA Areas of application • Measurement in liquids and solids • Reliable detection of buildup on the antenna Detailed description Special Documentation SD03093F Accessories The weather protection cover can be ordered together with the device via the "Accessory enclosed"...
Micropilot FMR60B PROFIBUS PA 115 (4.53) 140 (5.51) 32 (1.26) 165 (6.5) 140 (5.51) A0038280 64 Dimensions. Unit of measurement mm (in) Material Plastic Order number for accessories: 71438291 Mounting bracket, The device can be mounted on a wall or ceiling with the mounting bracket.
Micropilot FMR60B PROFIBUS PA Field Xpert SMT70 Universal, high-performance tablet PC for device configuration in Ex Zone 2 and non-Ex areas For details, see "Technical Information" TI01342S DeviceCare SFE100 Configuration tool for HART, PROFIBUS and FOUNDATION Fieldbus field devices Technical Information TI01134S...
For an overview of the scope of the associated Technical Documentation, refer to the following: • Device Viewer (www.endress.com/deviceviewer): Enter the serial number from the nameplate • Endress+Hauser Operations app: Enter serial number from nameplate or scan matrix code on nameplate. Endress+Hauser...
PROFIBUS User Organization e.V. (Profibus User Organization), Karlsruhe - Germany Bluetooth® The Bluetooth® word mark and logos are registered trademarks owned by the Bluetooth SIG, Inc. and any use of such marks by Endress+Hauser is under license. Other trademarks and trade names are those of their respective owners. Apple®...
Need help?
Do you have a question about the Micropilot FMR60B PROFIBUS PA and is the answer not in the manual?
Questions and answers