TI01699F/00/EN/01.23-00
71609844
2023-01-02
Products
Technical Information
Micropilot FMR62B
PROFINET with Ethernet-APL
Free space radar
Level measurement in liquids
Application
• Continuous, non-contact level measurement of liquids, pastes and sludges
• Process connections: Flanges
• Maximum measuring range: 80 m (262 ft)
• Temperature: –196 to +450 °C (–321 to +842 °F)
• Pressure: –1 to +160 bar (–14.5 to +2 321 psi)
• Accuracy: ±1 mm (±0.04 in)
Your benefits
• PTFE antenna or ceramic sealed high-temperature horn antenna
• Reliable measurement thanks to strong signal focusing, even with multiple
internal fixtures
• Easy, guided commissioning with intuitive user interface
• Bluetooth®wireless technology for commissioning, operation and maintenance
• Longer calibration cycles with Radar Accuracy Index
Solutions
Services

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Micropilot FMR62B PROFINET with Ethernet-APL and is the answer not in the manual?

Questions and answers

Summary of Contents for Endress+Hauser Micropilot FMR62B PROFINET with Ethernet-APL

  • Page 1 Products Solutions Services TI01699F/00/EN/01.23-00 71609844 2023-01-02 Technical Information Micropilot FMR62B PROFINET with Ethernet-APL Free space radar Level measurement in liquids Application • Continuous, non-contact level measurement of liquids, pastes and sludges • Process connections: Flanges • Maximum measuring range: 80 m (262 ft) •...
  • Page 2: Table Of Contents

    Micropilot FMR62B PROFINET with Ethernet-APL Table of contents Important document information ....3 Process ........44 Symbols .
  • Page 3: Important Document Information

    Micropilot FMR62B PROFINET with Ethernet-APL Important document information Symbols Safety symbols DANGER This symbol alerts you to a dangerous situation. Failure to avoid this situation will result in serious or fatal injury. WARNING This symbol alerts you to a dangerous situation. Failure to avoid this situation can result in serious or fatal injury.
  • Page 4: Graphic Conventions

    Micropilot FMR62B PROFINET with Ethernet-APL Graphic conventions • Installation, explosion and electrical connection drawings are presented in simplified format • Devices, assemblies, components and dimensional drawings are presented in reduced-line format • Dimensional drawings are not to-scale representations; the dimensions indicated are rounded off to 2 decimal places •...
  • Page 5: Input

    Micropilot FMR62B PROFINET with Ethernet-APL D = (c ∆t) / 2 where c is the speed of propagation of the wave. In summary, D can be calculated from the measured difference frequency Δf. D is then used to determine the content of the tank or silo.
  • Page 6 Micropilot FMR62B PROFINET with Ethernet-APL 100% A0051658  3 Usable measuring range Length of antenna + 10 mm (0.4 in) Usable measuring range 50 to 80 mm (1.97 to 3.15 in); medium εr < 2 Vessel height Reference point of measurement, varies depending on the antenna system For further information on the reference point, see →...
  • Page 7 To measure absorbing gases, either use a guided radar, measuring devices with another measuring frequency or another measuring principle. If measurements must be performed in one of these media, please contact Endress+Hauser. For the dielectric constants (DC values) of many media commonly used in industry, please refer •...
  • Page 8 Micropilot FMR62B PROFINET with Ethernet-APL Antenna, PTFE cladded flush mount, 50 mm (2 in) in storage vessel Media group Measuring range A0 (ε 1.2 to 1.4) 7 m (23 ft) A (ε 1.4 to 1.9) 12 m (39 ft) B (ε...
  • Page 9 Micropilot FMR62B PROFINET with Ethernet-APL PTFE Drip-off antenna, 50 mm (2 in) in buffer vessel Media group Measuring range A0 (ε 1.2 to 1.4) 4 m (13 ft) A (ε 1.4 to 1.9) 7 m (23 ft) B (ε 1.9 to 4) 13 m (43 ft) C (ε...
  • Page 10 Micropilot FMR62B PROFINET with Ethernet-APL Antenna, horn 316L, 65 mm (2.6 in) in buffer vessel Media group Measuring range A0 (ε 1.2 to 1.4) 11 m (36 ft) A (ε 1.4 to 1.9) 21 m (69 ft) B (ε 1.9 to 4) 40 m (131 ft) C (ε...
  • Page 11 Micropilot FMR62B PROFINET with Ethernet-APL Antenna, PTFE cladded flush mount, 80 mm (3 in) in vessel with agitator Media group Measuring range A0 (ε 1.2 to 1.4) 7 m (23 ft) A (ε 1.4 to 1.9) 13 m (43 ft) B (ε...
  • Page 12: Operating Frequency

    Micropilot FMR62B PROFINET with Ethernet-APL Measurement in bypass Bypass measuring conditions Application in vessels with moving medium surface (e.g. permanent free filling from above, mixing jets) Antenna, PTFE cladded flush mount, 80 mm (3 in) in bypass Media group Measuring range A0 (ε...
  • Page 13 Micropilot FMR62B PROFINET with Ethernet-APL Conformance Class Conformance Class B Netload Class Netload Class II Baud rates Automatic 10 Mbit/s with full-duplex detection Cycle times From 32 ms Polarity Auto-polarity for automatic correction of crossed TxD and RxD pairs Media Redundancy Protocol...
  • Page 14: Power Supply

    Micropilot FMR62B PROFINET with Ethernet-APL Power supply Terminal assignment Single compartment housing A0042594  4 Connection terminals and ground terminal in the connection compartment Positive terminal Negative terminal Internal ground terminal Dual compartment housing A0042803  5 Connection terminals and ground terminal in the connection compartment...
  • Page 15: Available Device Plugs

    Micropilot FMR62B PROFINET with Ethernet-APL Dual compartment housing, L-form A0045842  6 Connection terminals and ground terminal in the connection compartment Positive terminal Negative terminal Internal ground terminal Terminals • Supply voltage and internal ground terminal: 0.5 to 2.5 mm (20 to 14 AWG) •...
  • Page 16: Electrical Connection

    Micropilot FMR62B PROFINET with Ethernet-APL Electrical connection Connection examples PROFINET with Ethernet-APL A0045802  8 Connection example for PROFINET with Ethernet-APL Automation system APL field switch Observe cable specifications Transmitter Potential equalization The protective ground on the device must not be connected. If necessary, the potential matching line can be connected to the outer ground terminal of the transmitter before the device is connected.
  • Page 17: Cable Entries

    Micropilot FMR62B PROFINET with Ethernet-APL Cable entries A0046584 Single compartment housing, plastic Single compartment housing, aluminum Single compartment housing, 316L hygiene Dual compartment housing Dual compartment housing, L-form Cable entry Dummy plug The type of cable entry depends on the device version ordered.
  • Page 18: Performance Characteristics

    Micropilot FMR62B PROFINET with Ethernet-APL Depending on the type of port (DC power supply, input/output port) different testing levels according to IEC / DIN EN 61326-1 against transient overvoltages (Surge) are applied (IEC / DIN EN 61000-4-5 Surge): Test level on DC power ports and input/output ports is 1 000 V line to earth Devices with optional overvoltage protection •...
  • Page 19: Measured Value Resolution

    Micropilot FMR62B PROFINET with Ethernet-APL Differing values in near-range applications ∆ [mm (in)] 4 (0.16) 1 (0.04) -1 (-0.04) -4 (-0.16) D [m ( )] 0.8 (2.62) A0032636  9 Maximum measured error in near-range applications Δ Maximum measured error...
  • Page 20: Mounting

    Micropilot FMR62B PROFINET with Ethernet-APL Gas phase Temperature Pressure 1 bar (14.5 psi) 10 bar (145 psi) 25 bar (362 psi) +400 °C (+752 °F) –0.02 % +0.03 % +0.11 % Water (saturated steam) +100 °C (+212 °F) +0.02 % +180 °C (+356 °F)
  • Page 21: Orientation

    Micropilot FMR62B PROFINET with Ethernet-APL Orientation Internal vessel fittings α A0031777 Avoid internal fittings (point level switches, temperature sensors, struts, vacuum rings, heating coils, baffles etc.) inside the signal beam. Pay attention to the beam angle α. Avoiding interference echoes...
  • Page 22: Installation Instructions

    Micropilot FMR62B PROFINET with Ethernet-APL Radial alignment of the antenna Based on the directional characteristic, radial alignment of the antenna is not necessary. Installation instructions Horn antenna 65 mm (2.56 in) Information about the mounting nozzle The maximum nozzle length H depends on the nozzle diameter D.
  • Page 23 Micropilot FMR62B PROFINET with Ethernet-APL Antenna, PTFE cladded, flush mount 50 mm (2 in) Mounting cladded flanges Note the following for cladded flanges: • Use the same number of flange screws as the number of flange bores provided. • Tighten the screws with the necessary torque (see Table).
  • Page 24: Beam Angle

    Micropilot FMR62B PROFINET with Ethernet-APL Flange size Number of screws Tightening torque DN80 PN10/16 40 to 55 Nm DN80 PN25/40 40 to 55 Nm DN100 PN10/16 40 to 60 Nm DN100 PN25/40 55 to 80 Nm DN150 PN10/16 75 to 105 Nm ASME NPS 3"...
  • Page 25 Micropilot FMR62B PROFINET with Ethernet-APL α α A0031824  10 Relationship between beam angle α, distance D and beamwidth diameter W The beamwidth diameter W depends on the beam angle α and the distance D. Horn antenna 65 mm (2.56 in), α 4 °...
  • Page 26: Special Mounting Instructions

    Micropilot FMR62B PROFINET with Ethernet-APL PTFE cladded, flush mount 50 mm (2 in) antenna, α 7 ° W = D × 0.12 5 m (16 ft) 0.61 m (2.00 ft) 10 m (33 ft) 1.22 m (4.00 ft) 15 m (49 ft) 1.83 m (6.00 ft) 20 m (66 ft) 2.44 m (8.01 ft)
  • Page 27 Micropilot FMR62B PROFINET with Ethernet-APL • Measurements can be performed through an open full bore ball valve without any problems. • At the transitions, no gap exceeding 1 mm (0.04 in) may be left. • Opening diameter of ball valve must always correspond to the pipe diameter; avoid edges and constrictions.
  • Page 28 Micropilot FMR62B PROFINET with Ethernet-APL 100% A0046559  12 Example of stilling well design. Unit of measurement mm (in) Stilling well with holes; example for flush mount antenna 80 mm (3 in) Stilling well with slots Full bore ball valve e.g.
  • Page 29 Micropilot FMR62B PROFINET with Ethernet-APL Recommendations for the bypass • Metal (no plastic or enamel liner) • Constant diameter • Select an antenna that is as big as possible; recommendation, use 80 mm (3 in) • Difference in diameter between antenna and inner diameter of the bypass as small as possible •...
  • Page 30: Environment

    Micropilot FMR62B PROFINET with Ethernet-APL The material thickness can be a full multiple of the optimum thickness (table); it is important to note, however, that the microwave transparency decreases significantly with increasing material thickness. Optimum material thickness Material Optimum material thickness PE;...
  • Page 31 Micropilot FMR62B PROFINET with Ethernet-APL Plastic housing Plastic housing; process temperature –20 to +150 °C (–4 to +302 °F) A0032024  15 Plastic housing; process temperature –20 to +150 °C (–4 to +302 °F) = T : –20 °C (–4 °F) |  T : +76 °C (+169 °F)
  • Page 32 Micropilot FMR62B PROFINET with Ethernet-APL Restriction to a process temperature of 0 to +200 °C (+32 to +392 °F) with CSA C/US approval and plastic housing A0048826  18 Plastic housing; process temperature 0 to +200 °C (+32 to +392 °F) with CSA C/US approval = T...
  • Page 33 Micropilot FMR62B PROFINET with Ethernet-APL Plastic housing; process temperature –40 to +200 °C (–40 to +392 °F) A0032024  21 Plastic housing; process temperature –40 to +200 °C (–40 to +392 °F) = T : –40 °C (–40 °F) |  T : +76 °C (+169 °F) = T...
  • Page 34 Micropilot FMR62B PROFINET with Ethernet-APL Restriction to a process temperature of 0 to +280 °C (+32 to +536 °F) with CSA C/US approval and plastic housing A0048826  24 Plastic housing; process temperature 0 to +280 °C (+32 to +536 °F) with CSA C/US approval = T...
  • Page 35 Micropilot FMR62B PROFINET with Ethernet-APL Plastic housing; process temperature –60 to +150 °C (–76 to +302 °F) A0032024  27 Plastic housing; process temperature –60 to +150 °C (–76 to +302 °F) = T : –60 °C (–76 °F) |  T : +76 °C (+169 °F) = T...
  • Page 36 Micropilot FMR62B PROFINET with Ethernet-APL Restriction to a process temperature of 0 to +200 °C (+32 to +392 °F) with CSA C/US approval and plastic housing A0048826  30 CSA C/US approval and plastic housing; process temperature 0 to +200 °C (+32 to +392 °F) = T...
  • Page 37 Micropilot FMR62B PROFINET with Ethernet-APL Aluminum housing; process temperature –40 to +150 °C (–40 to +302 °F) A0032024  33 Aluminum housing, coated; process temperature –40 to +150 °C (–40 to +302 °F) = T : –40 °C (–40 °F) |  T : +79 °C (+174 °F) = T...
  • Page 38 Micropilot FMR62B PROFINET with Ethernet-APL Aluminum housing; process temperature –40 to +450 °C (–40 to +842 °F) A0032024  36 Aluminum housing, coated; process temperature –40 to +450 °C (–40 to +842 °F) = T : –40 °C (–40 °F) |  T : +79 °C (+174 °F) = T...
  • Page 39 Micropilot FMR62B PROFINET with Ethernet-APL Housing 316L 316L housing; process temperature –20 to +150 °C (–4 to +302 °F) A0032024  39 316L housing; process temperature –20 to +150 °C (–4 to +302 °F) = T : –20 °C (–4 °F) |  T : +77 °C (+171 °F)
  • Page 40 Micropilot FMR62B PROFINET with Ethernet-APL 316L housing; process temperature –40 to +200 °C (–40 to +392 °F) A0032024  42 316L housing; process temperature –40 to +200 °C (–40 to +392 °F) = T : –40 °C (–40 °F) |  T : +77 °C (+171 °F) = T...
  • Page 41 Micropilot FMR62B PROFINET with Ethernet-APL 316L housing; process temperature –60 to +150 °C (–76 to +302 °F) A0032024  45 316L housing; process temperature –60 to +150 °C (–76 to +302 °F) = T : –60 °C (–76 °F) |  T : +77 °C (+171 °F) = T...
  • Page 42 Micropilot FMR62B PROFINET with Ethernet-APL 316L housing, hygiene; process temperature –20 to +200 °C (–4 to +392 °F) A0032024  48 316L housing, hygiene; process temperature –20 to +200 °C (–4 to +392 °F) = T : –20 °C (–4 °F) |  T : +76 °C (+169 °F)
  • Page 43: Storage Temperature

    Micropilot FMR62B PROFINET with Ethernet-APL 316L housing, hygiene; process temperature –60 to +150 °C (–76 to +302 °F) A0032024  51 316L housing, hygiene; process temperature –60 to +150 °C (–76 to +302 °F) = T : –60 °C (–76 °F) |  T : +76 °C (+169 °F)
  • Page 44: Vibration Resistance

    Micropilot FMR62B PROFINET with Ethernet-APL • Thread G1/2, IP66/68 NEMA TYPE 4X/6P If the G1/2 thread is selected, the device is delivered with an M20 thread as standard and a G1/2 adapter is included with the delivery, along with the corresponding documentation •...
  • Page 45: Dielectric Constant

    –20 to +200 °C (–4 to +392 °F) The pressure range may be further restricted in the event of a CRN approval. Dielectric constant For liquids ε ≥  1.2 Contact Endress+Hauser for applications with lower dielectric constants than indicated. Endress+Hauser...
  • Page 46: Mechanical Construction

    Micropilot FMR62B PROFINET with Ethernet-APL Mechanical construction Dimensions The dimensions of the individual components must be added together for the total dimensions. Single compartment housing, plastic 94 (3.7) 107.5 (4.23) A0048768  53 Dimensions of single compartment housing, plastic (PBT). Unit of measurement mm (in)
  • Page 47 Micropilot FMR62B PROFINET with Ethernet-APL 316L single compartment housing, hygiene 92 (3.62) 123 (4.84) A0050364  55 Dimensions of 316L single compartment housing, hygiene. Unit of measurement mm (in) Height with cover with glass viewing window (dust Ex) Height with cover with plastic viewing window...
  • Page 48 Micropilot FMR62B PROFINET with Ethernet-APL Aluminum dual compartment housing 132 (5.2) 121 (4.76) 115 (4.53) 118 (4.65) 64 (2.52) 54 (2.13) 78 (3.07) 143 (5.63) A0038377  56 Dimensions of dual compartment housing. Unit of measurement mm (in) Height with cover with glass viewing window (devices for Ex d/XP, Dust-Ex)
  • Page 49 Micropilot FMR62B PROFINET with Ethernet-APL Aluminum or 316L dual compartment housing, L-form 110 (4.33) 101 (3.98) 140 (5.51) 138 (5.43) A0038381  57 Dimensions of dual compartment housing, L-form. Unit of measurement mm (in) Height with cover with glass viewing window (devices for Ex d/XP, Dust-Ex)
  • Page 50 Micropilot FMR62B PROFINET with Ethernet-APL Drip-off antenna - flange process connection 42.5 (1.67) A0046498  59 Dimensions of flange process connection. Unit of measurement mm (in) Process temperature version ≤150 °C (302 °F) Process temperature version ≤200 °C (392 °F)
  • Page 51 Micropilot FMR62B PROFINET with Ethernet-APL Antenna, cladded flush mount, PTFE, 50 mm (2 in), with flange 47.5 (1.87) A0046486  60 Dimensions of antenna, cladded flush mount, PTFE, 50 mm (2 in), with flange. Unit of measurement mm (in) Process temperature version ≤150 °C (302 °F) Process temperature version ≤200 °C (392 °F)
  • Page 52: Weight

    Micropilot FMR62B PROFINET with Ethernet-APL Antenna, cladded flush mount, PTFE, 80 mm (3 in), with flange 75 (2.95) A0046487  61 Dimensions of antenna, cladded flush mount, PTFE, 80 mm (3 in), with flange. Unit of measurement mm (in) Process temperature version ≤150 °C (302 °F) Process temperature version ≤200 °C (392 °F)
  • Page 53: Materials

    Micropilot FMR62B PROFINET with Ethernet-APL Drip-off antenna 50 mm (2 in) 1.70 kg (3.75 lb) + flange weight Antenna, cladded flush mount, PTFE, 50 mm (2 in) 1.50 kg (3.31 lb) + flange weight Antenna, cladded flush mount, PTFE, 80 mm (3 in) 2.9 kg (6.39 lb) + flange weight...
  • Page 54 Micropilot FMR62B PROFINET with Ethernet-APL Materials in contact with the medium DN65 horn antenna A0046618  62 Material; DN65 horn antenna. Unit of measurement mm (in) Horn: 316L / 1.4404 Antenna: Al (ceramic) Antenna seal: graphite Process connection: 316L / 1.4404 Housing adapter: 316L / 1.4404...
  • Page 55 Micropilot FMR62B PROFINET with Ethernet-APL Antenna, cladded flush mount, PTFE, 50 mm (2 in), with flange A0046609  64 Material; antenna, cladded flush mount, PTFE, 50 mm (2 in), with flange Antenna: PTFE, seal material: PTFE (cladding) Process connection: 316L / 1.4404 Housing adapter: 316L / 1.4404...
  • Page 56: Display And User Interface

    Micropilot FMR62B PROFINET with Ethernet-APL Display and user interface Operating concept Operator-oriented menu structure for user-specific tasks • Guidance • Diagnostics • Application • System Fast and safe commissioning • Interactive wizard with graphical user interface for guided commissioning in FieldCare, DeviceCare or DTM, AMS and PDM-based third-party tools or SmartBlue •...
  • Page 57: Local Display

    Micropilot FMR62B PROFINET with Ethernet-APL Local display Device display (optional) Functions: • Display of measured values and fault and notice messages • Background lighting, which switches from green to red in the event of an error • The device display can be removed for easier operation A0039284 ...
  • Page 58: System Integration

    A0039148 Computer with FieldCare/DeviceCare operating tool Commubox FXA291 Service interface (CDI) of the measuring device (= Endress+Hauser Common Data Interface) Via Web browser Function scope Thanks to the integrated Web server the device can be operated and configured via a Web browser.
  • Page 59: Ce Mark

    Micropilot FMR62B PROFINET with Ethernet-APL CE mark The measuring system meets the legal requirements of the applicable EU directives. These are listed in the corresponding EU Declaration of Conformity together with the standards applied. The manufacturer confirms successful testing of the device by affixing to it the CE mark.
  • Page 60: En 302372 Radio Standard

    Micropilot FMR62B PROFINET with Ethernet-APL Astronomy stations Country Name of the station Latitude Longitude Germany Effelsberg 50° 31'   32" North 06° 53'   00" East Finland Metsähovi 60° 13'   04" North 24° 23'   37" East Tuorla 60° 24'   56" North 24° 26'   31" East France Plateau de Bure 44° 38'  ...
  • Page 61: Certification Profinet With Ethernet-Apl

    Micropilot FMR62B PROFINET with Ethernet-APL This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) This device may not interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.
  • Page 62: Calibration

    • Automatic verification of exclusion criteria • Automatic creation of the order code and its breakdown in PDF or Excel output format • Ability to order directly in the Endress+Hauser Online Shop Calibration Factory calibration certificate The calibration points are spread evenly over the measuring range (0 to 100 %).
  • Page 63: Test, Certificate, Declaration

    Condition Monitoring system and the in-situ verification of devices in the application. The application package can be ordered together with the device or can be activated subsequently with an activation code. Detailed information on the order code is available via the Endress+Hauser website www.endress.com...
  • Page 64: Accessories

    Micropilot FMR62B PROFINET with Ethernet-APL Heartbeat Monitoring Foam detection wizard and Build-up detection wizard are available, process windows can be configured. Furthermore, additional monitoring parameters can be displayed and used for predictive maintenance or application optimization. "Foam detection" wizard This wizard configures the automatic foam detection.
  • Page 65: Plastic Weather Protection Cover

    Micropilot FMR62B PROFINET with Ethernet-APL 228.9 (9.01) 136.4 (5.37) 92.5 (3.64) 170.5 (6.71) 81 (3.19) 103 (4.06) A0039231  69 Dimensions. Unit of measurement mm (in) Material • Weather protection cover: 316L • Clamping screw: A4 • Holder: 316L Order number for accessories:...
  • Page 66: Remote Display Fhx50B

    Micropilot FMR62B PROFINET with Ethernet-APL M12 socket, straight • Material: Body: PBT; union nut: nickel-plated die-cast zinc; seal: NBR • Degree of protection (fully locked): IP67 • Pg coupling: Pg7 • Order number: 52006263 A0051232  72 M12 socket, angled M12 socket, angled •...
  • Page 67: Gas-Tight Feedthrough

    Micropilot FMR62B PROFINET with Ethernet-APL A0046692 Plastic single compartment housing, remote display Aluminum single compartment housing, remote display Single compartment housing, 316L hygiene, remote display Device side, plastic single compartment housing prepared for display FHX50B Device side, aluminum single compartment housing prepared for display FHX50B...
  • Page 68: Field Xpert Smt70

    For an overview of the scope of the associated Technical Documentation, refer to the following: • Device Viewer (www.endress.com/deviceviewer): Enter the serial number from the nameplate • Endress+Hauser Operations app: Enter serial number from nameplate or scan matrix code on nameplate. Document function...
  • Page 69 Micropilot FMR62B PROFINET with Ethernet-APL Bluetooth® The Bluetooth® word mark and logos are registered trademarks owned by the Bluetooth SIG, Inc. and any use of such marks by Endress+Hauser is under license. Other trademarks and trade names are those of their respective owners. Apple®...
  • Page 72 *71609844* 71609844 www.addresses.endress.com...

Table of Contents