Whirlpool WHVS 90F LT C K Instructions For Use Manual page 15

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
The hood automatically sets extraction speed (power) 1 and then increases it if the environmental conditions detected by
the hood sensor require it.
If there is no change in the environmental conditions, after 5 minutes (if the hood is already at extraction speed (power) 1),
the hood switches off.
Note: for the correct use of this function, adjust the relative parameters first (see the paragraph "Adjusting the parameters
for automatic operation").
Note: during automatic operation, if the user uses other functions that adjust the speed, the auto ventilation function is
deactivated.
T9. FILTER SATURATION INDICATOR
At regular intervals, the hood signals the need to perform maintenance on the filters.
Note: the indicators are activated when the hood is on.
Key T9 on: the grease filter requires maintenance.
Key T9 flashing: the activated carbon filter requires maintenance.
Reset filter saturation indicator:
Note: this operation must be performed with the hood on.
Press and hold T9; the light goes out, indicating that the reset was successful.
Activation of the activated carbon filter saturation indicator.
Note: this operation must be performed with the extraction motor off.
This indicator is normally deactivated; it must be activated if the hood is installed in the filter version, i.e. in the
presence of activated carbon filters.
Simultaneously press and hold keys T1 and T10 to activate the function: the keys will light up, indicating activation.
To deactivate the function, press and hold the same keys (T1 and T10) again: the keys will flash briefly, then go out,
indicating deactivation.
T10. "BREATH DAILY CYCLE" OPERATING MODE ON/OFF
The hood automatically sets extraction speed (power) 1 and then increases it if the environmental conditions detected by
the hood sensor require it.
If the extraction speed is not changed, depending on the environmental conditions detected, the hood switches off after 2
hours.
In any case, after 5 hours the hood is switched off forcefully.
Note: for the correct use of this function, adjust the relative parameters first (see the paragraph "Adjusting the parameters
for
automatic operation).
T11. "BREATH INTENSIVE CYCLE" OPERATING MODE ON/OFF
The hood automatically sets extraction speed (power) 5 and then increases it if the environmental conditions detected by
the hood sensor require it.
If the extraction speed is not changed, depending on the environmental conditions detected, the hood switches off after 2
hours.
In any case, after 5 hours the hood is switched off forcefully.
Note: for the correct use of this function, adjust the relative parameters first (see the paragraph "Adjusting the parameters
for automatic operation").
T12. WI-FI FUNCTION ACTIVE LIGHT INDICATOR
The indicator lights up when the hood is controlled remotely via App.
T13. WI-FI CONNECTION
Press to activate/deactivate the Wi-Fi functions.
This function allows the product to be connected to the Internet and remotely monitor/control the hood via a Smartphone or
Tablet.
To use the Wi-Fi function, the device must be connected to the home wireless network (internet) according to the
configuration procedure described in the "WI-FI MANUAL" instructions.
ADJUSTING THE PARAMETERS FOR AUTOMATIC OPERATION
For the correct use of automatic operation, perform "Hood calibration" and "Hob selection".
Hood calibration
Note: this operation must be performed in standby mode, i.e. 1 minute after the motor has been switched off Press key T4
for 5 seconds.
6

Advertisement

Table of Contents
loading

Table of Contents