PIETRO FIORENTINI SSM-AQUO Use And Maintenance Manual

PIETRO FIORENTINI SSM-AQUO Use And Maintenance Manual

Static smart cold water meter
Table of Contents

Advertisement

Quick Links

SSM-AQUO
Static smart cold water meter
USE, MAINTENANCE
USE, MAINTENANCE
Revision A - Edition 08/2023
AND WARNING
AND WARNING
MANUAL
MANUAL
EN

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SSM-AQUO and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for PIETRO FIORENTINI SSM-AQUO

  • Page 1 SSM-AQUO Static smart cold water meter Revision A - Edition 08/2023 USE, MAINTENANCE USE, MAINTENANCE AND WARNING AND WARNING MANUAL MANUAL...
  • Page 2 StAtic SmARt cold wAtER mEtER iNtRodUctioN REV. A Use, maintenance and warning manual Use, maintenance and warning manual...
  • Page 3: Introduction

    NOTICE! Details of the product may differ from the images in this document. Revision: A COPYRIGHT 2023 © PIETRO FIORENTINI S.P.A. StAtic SmARt cold wAtER mEtER iNtRodUctioN REV. A Use, maintenance and warning manual...
  • Page 4 StAtic SmARt cold wAtER mEtER iNtRodUctioN REV. A Use, maintenance and warning manual...
  • Page 5: Revision History

    1.1 - REVISION HISTORY Revision Date Revision contents index 08/2023 First issue Tab. 1.1. StAtic SmARt cold wAtER mEtER iNtRodUctioN REV. A Use, maintenance and warning manual...
  • Page 6: Table Of Contents

    INDEX 1 - INTRODUCTION ........................3 1.1 - REViSioN HiStoRY ..........................5 2 - GENERAL INFORMATION ....................9 2.1 - mANUFActURER idENtiFicAtioN ......................9 2.2 - idENtiFicAtioN oF tHE PRodUct ......................9 2.3 - REGUlAtoRY FRAmEwoRK ......................... 10 2.4 - wARRANtY ............................10 2.4.1 - REFERENcE oPERAtiNG coNditioNS ....................11 2.5 - AddRESSEES, SUPPlY ANd StoRAGE oF tHE mANUAl ..............
  • Page 7 6.1.1 - PAcKAGiNG ANd FAStENERS USEd FoR tRANSPoRt ..............40 6.2 - PAcKAGiNG coNtENt .......................... 40 6.3 - PHYSicAl cHARActERiSticS oF tHE EQUiPmENt ................41 6.3.1 - SSm-AQUo ............................41 6.4 - EQUiPmENt ANcHoRiNG ANd liFtiNG mEtHod................42 6.4.1 - FoRKliFt HANdliNG mEtHod ......................43 6.5 - PAcKAGiNG REmoVAl ..........................
  • Page 8 7 - INSTALLATION ........................47 7.1 - GENERAl wARNiNGS ........................... 47 7.2 - iNStAllAtioN PRE-REQUiSitES ......................47 7.2.1 - AllowEd ENViRoNmENtAl coNditioNS ..................47 7.3 - cHEcKS BEFoRE iNStAllAtioN ......................48 7.4 - SPEciFic SAFEtY iNStRUctioNS FoR tHE iNStAllAtioN StEP ............48 7.5 - iNStAllAtioN REQUiREmENtS ......................
  • Page 9: General Information

    Address Tel. +39 0444 968511 Fax +39 0444 960468 www.fiorentini.com sales@fiorentini.com Tab. 2.2. NOTICE! For any problems with the equipment, please contact PIETRO FIORENTINI S.p.A.. 2.2 - IDENTIFICATION OF THE PRODUCT Equipment coNtAtoRE SmARt StAtico PER AcQUA FREddA Series SSm-AQUo •...
  • Page 10: Regulatory Framework

    PiEtRo FioRENtiNi S.P.A. guarantees that the equipment was manufactured using the best materials, with high quality workmanship, and complies with the quality requirements, specifications and performance set out in the order. the warranty shall be considered null and void and PiEtRo FioRENtiNi S.P.A. shall not be liable for any damage and/or malfunctions: •...
  • Page 11: Reference Operating Conditions

    2.4.1 - REFERENCE OPERATING CONDITIONS the reference operating conditions for battery life calculations can be found at tab. 2.4: Operative Reference indications condition display always active (automatic menu scrolling) User interface 15 minutes per month (NFc/Zvei interface) Upgrade local: No. 3 (within the equipment's service life) firmware code wireless m-Bus version: •...
  • Page 12: Addressees, Supply And Storage Of The Manual

    Removing, rewriting or editing the pages of the manual and their contents is not allowed. PIETRO FIORENTINI S.p.A. shall not be held liable for any damage to people, animals and property caused by failure to adhere to the warnings and operating procedures described in this manual.
  • Page 13: Symbols Used In The Manual

    2.7 - SYMBOLS USED IN THE MANUAL Symbol Definition Symbol used to identify important warnings for the safety of the operator and/or equipment. Symbol used to identify information of particular importance in the instruction manual. the information may also concern the safety of the personnel involved in using the equipment. obligation to consult the instruction manual/booklet.
  • Page 14: Equipment Identification

    2.8 - EQUIPMENT IDENTIFICATION The equipment is equipped with identification silk screens. The rating plates specify identification details of the equipment to be provided, if necessary, to PIETRO FIORENTINI S.p.A. At tab. 2.7 the equipment identifier: Type of plate Image mod.
  • Page 15: Identifier Of The Logic Device

    2.8.1 - IDENTIFIER OF THE LOGIC DEVICE Term Description Format Fio-w-07-ZV-YY-XXXXXX Fixed field indicating the manufacturer (PIETRO FIORENTINI S.p.A.) according to the encoding of the Flag Association Reserved device type (water meter) measurement technology communication technology Year of manufacture XXXXXX Progressive number Tab.
  • Page 16: Remote Communication Type

    2.8.1.2 - REMOTE COMMUNICATION TYPE Code Type of communication Model code “V” version wireless m-Bus & loRawAN integrated NB-iot integrated Tab. 2.10. 2.8.2 - DESCRIPTION OF IDENTIFYING ELEMENTS the information described in tab. 2.11 can be found on the identification silkscreen: Pos.
  • Page 17 Fig. 2.1. Description of the nameplates StAtic SmARt cold wAtER mEtER GENERAl iNFoRmAtioN REV. A Use, maintenance and warning manual...
  • Page 18: Glossary Of Measurement Units

    2.9 - GLOSSARY OF MEASUREMENT UNITS Type of measurement Unit of measurement Description m³ cubic metres Consumption and Volumetric flow rate litres per hour Temperature °c degree centigrade Tab. 2.12. 2.10 - QUALIFIED PROFESSIONAL FIGURES Qualified operators in charge of using and managing the equipment throughout its technical service life to be used as indicated: Professional figure...
  • Page 19: Safety

    3.1.2 - POWER SUPPLY DEVICES SSM-AQUO can only be powered by the specific battery pack approved with the device; using other power sources is prohibited. the device uses a single battery pack to manage the metrology part, the local interfaces and the remote communication part.
  • Page 20: Safety Instructions For Installation

    Upon receipt of the device, examine the supplied material. immediately report any shipping damage. Storage As a rule, SSm-AQUo must be stored in a horizontal position and in a dry place at room temperature (refer to paragraph 6.6.1). WARNING! •...
  • Page 21: Personal Protective Equipment

    3.2 - PERSONAL PROTECTIVE EQUIPMENT the following table shows the Personal Protective Equipment (PPE) and its description; an obligation is associated with each symbol. Personal protective equipment means any equipment intended to be worn by the worker in order to protect them against one or several risks that are likely to threaten their safety or health during work.
  • Page 22: Obligations And Prohibitions

    3.3 - OBLIGATIONS AND PROHIBITIONS the following is a list of obligations and prohibitions to be observed for the safety of the operator. it is mandatory to: • carefully read and understand the use, maintenance and warning manual; • before installing the equipment, strictly refer to the details specified on the nameplates and in the manual; •...
  • Page 23: Residual Risks

    WARNING! If there are any functional faults, do not operate. Immediately contact PIETRO FIORENTINI S.p.A. for the necessary directions. WARNING! It is mandatory to implement protective measures against electrostatic discharges during installation, configuration and maintenance of the equipment.
  • Page 24: Safety And Fraud Prevention

    3.5 - SAFETY AND FRAUD PREVENTION the solutions implemented on the equipment to assure safety comply with the requirements set forth by the reference standard in force. in detail, access: • to the electronics is not possible without removing the mechanical metrological seals and without causing permanent damage to the metrological cover, in accordance with that described in the legalisation plan indicated in the type ex- amination certificate (MID) of the meter;...
  • Page 25: Safety Pictograms

    NOISE LEVEL SSm-AQUo is a static meter and has no moving parts. For the value of the noise generated by the equipment and further information, contact PiEtRo FioRENtiNi S.p.A. ATTENTION! The obligation to use earmuffs or ear plugs to protect the hearing of qualified professional figures (refer- ence paragraph 2.10) remains in the event that the noise in the installation environment of the equipment...
  • Page 26 StAtic SmARt cold wAtER mEtER SAFEtY REV. A Use, maintenance and warning manual...
  • Page 27: Description And Operation

    States relating to the making available on the market of measuring instruments (implemented in the italian Republic by Government decree no. legislative decree 84/2016. as amended). the SSm-AQUo water meters consist of a brass body with threaded connections, a pair of ultrasonic transducers and the electronic display device.
  • Page 28: Power Supply Devices

    4.1.1.1 - CONNECTION OF THE POWER SUPPLY DEVICES NOTICE! The SSM-AQUO device is supplied with the battery pack already connected and ready for use in the field. 4.1.1.2 - POWER SUPPLY STATUS A calculation is made of the actual consumption, based on: •...
  • Page 29: Acquisition Of The Measure

    4.1.2 - ACQUISITION OF THE MEASURE The flow of water volumes (flow rate) is measured continuously by means of specific sensors, connected to the calculation board via an electrical connection. the governing microprocessor: • pilots the detection of the flow rate and temperature sensors; •...
  • Page 30: User Interface

    “improper”. in the event of “improper use”, PiEtRo FioRENtiNi S.p.A. shall not be held liable for any damage caused to people or property, and any type of warranty on the equipment shall be deemed void.
  • Page 31: Technical Data

    4.3 - TECHNICAL DATA General features Electronic casing Polycarbonate Enclosure size Alloy brass cw617N-dw, according to EN 12165 Casing protection rating iP68 Maximum working pressure 16 bar Operating temperature range -25° c + 55° c Water temperature range +0.1° c + 50° c Storage temperature range -25°c + 55°...
  • Page 32 StAtic SmARt cold wAtER mEtER dEScRiPtioN ANd oPERAtioN REV. A Use, maintenance and warning manual...
  • Page 33: User Interface

    Pos. Element Description lcd display Allows you to consult the data provided by the equipment. black and white with segments Tab. 5.23. Fig. 5.3. User interface SSM-AQUO StAtic SmARt cold wAtER mEtER USER iNtERFAcE REV. A Use, maintenance and warning manual...
  • Page 34: Lcd Display Description

    5.2 - LCD DISPLAY DESCRIPTION Fig. 5.4. LCD Display SSM-AQUO tab. 5.24 describes the main elements on the display (Fig. 5.4): Pos. Description ICONS FIELD Flow direction: ► direct flow ◀ reverse flow low battery Pipe rupture, sudden increase in water flow rate...
  • Page 35: Navigation Procedure

    5.3 - NAVIGATION PROCEDURE the SSm-AQUo equipment display is always on. there are no navigation buttons, and the menu displays data cyclically according to the manufacturer's predefined schedule indicated in tab. 5.25. the display can be customised by extending the menu from the manufacturer via the NFc interface.
  • Page 36: Alarms

    5.3.2 - ALARMS tab. 5.26 indicates the sequence for the following display during the chapter selection phase: Field shown on display How much is activated How much is deactivated Presence of water in the pipe, automat- Empty pipe: no water in the pipe ically reset Leakage: detects continuous flow When the flow is interrupted, it is auto-...
  • Page 37: Data Logger

    5.4 - DATA LOGGER the line of SSm-AQUo ultrasonic smart water meters has data storage memory with FiFo logic. the recorded values (refer to the 'Variable' column of tab. 5.27) are stored: • each hour ('Hourly data') • at midnight ('daily data') •...
  • Page 38 Transmis- Typical Transmission Power Protocol Data transmitted sion calendar window output • Absolute totaliser • date and time • Alarms (par. 5.3.2) • Recorded volumes (in litres) - mid- night (24:00) Random in the loRawAN two-way 2 tx per day 14dBm •...
  • Page 39: Transport And Handling

    6 - TRANSPORT AND HANDLING 6.1 - SPECIFIC WARNINGS FOR TRANSPORT AND HANDLING NOTICE! Transport and handling must be carried out in compliance with the regulations in force in the country of installation by personnel who are: • qualified (specially trained); •...
  • Page 40: Packaging And Fasteners Used For Transport

    PiEtRo FioRENtiNi S.p.A.. NOTICE! PIETRO FIORENTINI S.p.A. shall not be liable for any damage to people or property caused by accidents due to failure to comply with the instructions provided in this manual. tab. 6.30 describes the types of packaging used: Ref.
  • Page 41: Physical Characteristics Of The Equipment

    6.3 - PHYSICAL CHARACTERISTICS OF THE EQUIPMENT 6.3.1 - SSM-AQUO Fig. 6.5. Dimensions SSM-AQUO - brass version Dimensions DN (mm) DN 15 DN 20 DN 25 DN 32 DN 40 Nominal dimensions inches 1/2” 3/4” 1” 1” 1/4 1” 1/2...
  • Page 42: Equipment Anchoring And Lifting Method

    6.4 - EQUIPMENT ANCHORING AND LIFTING METHOD HAZARD! Using lifting equipment (if necessary) for unloading, carrying and handling packages is reserved only for skilled operators who have been properly trained (and are appropriately qualified if required by the regula- tions in force in the country of installation) and are familiar with: •...
  • Page 43: Forklift Handling Method

    6.4.1 - FORKLIFT HANDLING METHOD HAZARD! It is forbidden to: • Do not transit under suspended loads; • Do not move the load over the personnel operating in the site/plant area. WARNING! The following is not allowed on forklifts: • carrying passengers;...
  • Page 44 Step Action Image Sollevare lentamente il carico di qualche decina di centimetri e veri carne la stabilità facendo attenzio- Inclinare il montante all’indietro (verso il posto guida) per avvantaggiare il momento ribaltante e Adeguare la velocità d ne che il baricentro del carico sia posizionato al centro delle forche di sollevamento. garantire una maggiore stabilità...
  • Page 45: Packaging Removal

    • do not install the equipment; • contact PIETRO FIORENTINI S.p.A. and specify the details provided on the equipment nameplate. WARNING! The single piece of equipment is contained in a specifically created cardboard box. Avoid taking the equipment out of the box before its installation.
  • Page 46: Storage And Environmental Conditions

    6.6 - STORAGE AND ENVIRONMENTAL CONDITIONS WARNING! Protect the equipment from blows and impacts, even accidental, until it is installed. NOTICE! The meters must be stored in an upright position. if the equipment needs to be stored for an extended period, the minimum environmental conditions for the intended stor- age are provided in tab.
  • Page 47: Installation

    WARNING! It is strictly forbidden to make any modifications to the equipment. WARNING! PIETRO FIORENTINI S.p.A. is not liable for damage caused by incorrect installation of the equipment and/ or otherwise different from that indicated in this manual. 7.2 - INSTALLATION PRE-REQUISITES 7.2.1 - ALLOWED ENVIRONMENTAL CONDITIONS...
  • Page 48: Checks Before Installation

    7.3 - CHECKS BEFORE INSTALLATION the installation site must be suitable for the safe use of the equipment. the equipment installation area must have lighting that guarantees the operator good visibility during the installation phas- Before installation, it must be ensured that: •...
  • Page 49: Installation Requirements

    WARNING! Check the distance between couplings to avoid mechanical stress (U+D < 5 mm) Fig. 7.8. Distance between SSM-AQUO meter and the joints NOTICE! The equipment is class U0D0 and does not require a straight section before and after the meter.
  • Page 50: Installation Procedure

    7.6 - INSTALLATION PROCEDURE to install the meter (A), proceed as described at tab. 7.39: Step Action Remove any packaging or protection present install new gaskets in the pipe connections NOTICE! Gaskets are not included in the meter package. Position the meter in accordance with the flow direction indicated on the side of the meter Fasten the nuts according to the tightening torques indicated in the table tab.
  • Page 51: Tightening Torques

    Tightening Torque (Nm) Tab. 7.40. 7.8 - EQUIPMENT ADJUSTMENTS NOTICE! The equipment is adjusted as required by the Customer, directly in the facility PIETRO FIORENTINI S.p.A. No further adjustments are required. StAtic SmARt cold wAtER mEtER iNStAllAtioN REV. A Use, maintenance and warning manual...
  • Page 52 StAtic SmARt cold wAtER mEtER iNStAllAtioN REV. A Use, maintenance and warning manual...
  • Page 53: Configuration

    To activate communication with SSM-AQUO: approach the reader device and submit the access credentials defined in the order (installer profile and password). Place the probe head in the appropriate slot on the front part of SSm-AQUo with the cable facing downwards. the slot will help the device to be put in place.
  • Page 54 StAtic SmARt cold wAtER mEtER coNFiGURAtioN REV. A Use, maintenance and warning manual...
  • Page 55: Maintenance And Functional Checks

    9 - MAINTENANCE AND FUNCTIONAL CHECKS 9.1 - ROUTINE MAINTENANCE NOTICE! There are no routine maintenance activities. 9.2 - SPECIAL MAINTENANCE NOTICE! There are no special maintenance activities. StAtic SmARt cold wAtER mEtER mAiNtENANcE ANd FUNctioNAl cHEcKS REV. A Use, maintenance and warning manual...
  • Page 56 StAtic SmARt cold wAtER mEtER mAiNtENANcE ANd FUNctioNAl cHEcKS REV. A Use, maintenance and warning manual...
  • Page 57: Uninstallation And Disposal

    10 - UNINSTALLATION AND DISPOSAL 10.1 - QUALIFICATION OF THE OPERATORS IN CHARGE Uninstallation Operator qualification • Qualified uninstallation operator WARNING! The PPE listed in this table is related to the risk associated with the equipment. PPE required For the PPE required to protect against risks associated with the workplace, installation or operating conditions, please refer to: •...
  • Page 58: Information Required In Case Of New Installation

    10.3 - INFORMATION REQUIRED IN CASE OF NEW INSTALLATION NOTICE! Should the equipment be reused after uninstallation, refer to chapters: “Installation” and “Configuration”. 10.4 - STORAGE OF THE BATTERIES NOTICE! Refer to paragraph 6.6 to store the batteries. 10.5 - INFORMATION REQUIRED IN CASE OF RE-INSTALLATION NOTICE! Should the equipment be reused after uninstallation, refer to chapter “7 - Installation”...
  • Page 59: Disposal Information

    10.6 - DISPOSAL INFORMATION NOTICE! • Proper disposal prevents damage to humans and the environment and promotes the reuse of precious raw materials. • Bear in mind that the regulations in force in the country of installation must be complied with. •...
  • Page 60: Disposing Of The Batteries

    10.6.1 - DISPOSING OF THE BATTERIES Proceed with disposal in compliance with the requirements: • on transport and packaging in the chapter; • of the legislation in force in the country of installation of the equipment. WARNING! When disposing of the batteries, they must be removed from the equipment, as indicated in Directive 2006/66/EC art.12 paragraph 3.
  • Page 61: Recommended Spare Parts

    It is recommended to use original spare partsPIETRO FIORENTINI S.p.A. PIETRO FIORENTINI S.p.A. shall not be held liable for any damage caused by using non-original parts. 11.2 - HOW TO REQUEST SPARE PARTS the SSm-AQUo device has no replaceable parts.
  • Page 62 TM0109ENG...

Table of Contents