PIETRO FIORENTINI SSM-ICON 250 Manual

PIETRO FIORENTINI SSM-ICON 250 Manual

Static smart meter
Table of Contents

Advertisement

Quick Links

SSM-ICON 250
Static smart meter
OPERATION, MAINTENANCE
OPERATION, MAINTENANCE
AND WARNING MANUAL
AND WARNING MANUAL
Review A - Edition 05/2023
EN

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SSM-ICON 250 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for PIETRO FIORENTINI SSM-ICON 250

  • Page 1 SSM-ICON 250 Static smart meter Review A - Edition 05/2023 OPERATION, MAINTENANCE OPERATION, MAINTENANCE AND WARNING MANUAL AND WARNING MANUAL...
  • Page 2 StAtic SmARt mEtER iNtRODUctiON | REV Operation, maintenance and warning manual Operation, maintenance and warning manual...
  • Page 3: Introduction

    The images in this document are indicative of the product type and may differ in the details. Revision: A COPYRIGHT 2023 © PIETRO FIORENTINI S.P.A. StAtic SmARt mEtER iNtRODUctiON | REV Operation, maintenance and warning manual...
  • Page 4 StAtic SmARt mEtER iNtRODUctiON | REV Operation, maintenance and warning manual...
  • Page 5: Revision History

    1.1 - REVISION HISTORY Revision Date Review Contents index 05/2023 First issue Tab. 1.1. StAtic SmARt mEtER iNtRODUctiON | REV Operation, maintenance and warning manual...
  • Page 6: Table Of Contents

    INDICE 1 - INTRODUCTION ........................3 1.1 - REViSiON HiStORY ..........................5 2 - GENERAL INFORMATION ....................11 2.1 - mANUFActURER iDENtiFicAtiON ......................11 2.2 - PRODUct iDENtiFicAtiON ........................11 2.3 - REGULAtORY FRAmEWORK ......................... 12 2.4 - WARRANtY ............................12 2.4.1 - REFERENcE OPERAtiNG cONDitiONS ....................13 2.5 - REciPiENtS, SUPPLY AND cONSERVAtiON OF tHE mANUAL ............
  • Page 7 4 - DESCRIPTION AND OPERATION ..................31 4.1 - GENERAL DEScRiPtiON ........................31 4.1.1 - POWER DEVicES ..........................32 4.1.1.1 - cONNEctiON OF POWER DEVicES ...................32 4.1.1.2 - POWER StAtUS ..........................32 4.1.2 - SHUt-OFF VALVE ..........................33 4.1.3 - mEASUREmENt AcQUiSitiON ......................34 4.1.4 - DiFFERENtiAL PRESSURE AcQUiSitiON ....................34 4.1.5 - AcQUiSitiON OF AmBiENt tEmPERAtURE ..................34 4.1.6 - AcQUiSitiON OF SEiSmic EVENtS .....................34...
  • Page 8 6 - TRANSPORT AND HANDLING ..................47 6.1 - SPEciFic WARNiNGS FOR tRANSPORt AND HANDLiNG ..............47 6.1.1 - PAcKAGiNG AND FAStENiNG SYStEmS USED FOR tRANSPORt ............47 6.2 - PAcKAGE cONtENtS ........................... 48 6.3 - PHYSicAL cHARActERiSticS OF tHE EQUiPmENt ................49 6.4 - mEtHOD FOR ANcHORiNG AND LiFtiNG tHE EQUiPmENt ..............
  • Page 9 10 - UNINSTALLATION AND DISPOSAL ................. 69 10.1 - GENERAL SAFEtY WARNiNGS ......................69 10.2 - QUALiFicAtiON OF tHE OPERAtORS iN cHARGE ................69 10.3 - UNiNStALLiNG ............................69 10.4 - iNFORmAtiON NEEDED iN cASE OF NEW iNStALLAtiON ..............70 10.5 - iNFORmAtiON NEEDED iN cASE OF RE-iNStALLAtiON ..............
  • Page 10 StAtic SmARt mEtER iNtRODUctiON | REV Operation, maintenance and warning manual...
  • Page 11: General Information

    2 - GENERAL INFORMATION 2.1 - MANUFACTURER IDENTIFICATION Manufacturer PiEtRO FiORENtiNi S.P.A. Via Enrico Fermi, 8/10 36057 Arcugnano (Vi) - itALY Address Tel. +39 0444 968511 Fax +39 0444 960468 www.fiorentini.com sales@fiorentini.com Tab. 2.2. For any problems found on the equipment, contact your gas network distributor.
  • Page 12: Regulatory Framework

    REGULATORY FRAMEWORK PiEtRO FiORENtiNi S.P.A. with registered office in Arcugnano (Italy) - Via E. Fermi, 8/10, declares that the equipment in the series SSm-icON 250 that this manual refers to is designed, manufactured, tested and controlled in accordance with the requirements of the following standards: •...
  • Page 13: Reference Operating Conditions

    2.4.1 - REFERENCE OPERATING CONDITIONS the reference operating conditions for battery life calculation are described in tab. 2.4: Operating Reference indications condition 15 minutes per month (local interface) User interface 15 minutes per month (Display) Shut-off 1 handling cycle (opening/closing) each week valve Firmware code 3 times in 20 years...
  • Page 14: Recipients, Supply And Conservation Of The Manual

    It is forbidden to remove, rewrite or modify the pages of the manual and their contents. PIETRO FIORENTINI S.p.A. declines all responsibility for any damage to people, animals and things caused by failure to observe the warnings and operating methods described in this manual.
  • Page 15: Symbols Used In The Manual

    2.7 - SYMBOLS USED IN THE MANUAL Symbol Definition Symbol used to identify important warnings for operator and/or equipment safety. Symbol used to identify particularly important information in the manual. the information may also concern the safety of personnel involved in using the equipment. Obligation to consult the instruction manual/booklet.
  • Page 16: Identification Plates Applied

    SSm-icON-250-U7-Ntc Tab. 2.7. It is absolutely forbidden to remove the identification plates and/or replace them with others. If, for accidental reasons, the plates are damaged or removed, the customer must inform PIETRO FIORENTINI S.p.A. StAtic SmARt mEtER GENERAL iNFORmAtiON REV.
  • Page 17: Device Identifier

    2.8.1 - DEVICE IDENTIFIER Type Description Sequential number indicating the identification code of a meter assigned by METER SERIAL NUMBER the manufacturer. Sequential number indicating the identification code of a meter assigned by PURCHASER'S BADGE the customer. Tab. 2.8. StAtic SmARt mEtER GENERAL iNFORmAtiON REV.
  • Page 18: Description Of Identification Plates

    2.8.2 - DESCRIPTION OF IDENTIFICATION PLATES The identification plate bears the information described in tab. 2.9: Pos. Description manufacturer's Logo Identification of the gas inlet connection Static smart meter series. Meter class as defined by ANSI B109.1 Class, Division, and Group as defined by NEC500 Operating ambient temperature range Year of manufacture of the meter Reference temperature for volume conversion...
  • Page 19: Measurement Unit Glossary

    2.9 - MEASUREMENT UNIT GLOSSARY Measurement type Unit of measurement Description Scfh Standard cubic feet per hour Standard cubic feet Consumption and Volumetric flow cfh/h cubic meters per hour cubic feet Pressure ˝wc inch of water column Pascal °c celsius degree Temperature °F Degree Fahrenheit...
  • Page 20 Professional Definition trained and licensed technician to operate and manage the equipment who must: • be able to carry out all the operations necessary for the proper functioning of the equip- ment and system, guaranteeing their own safety and that of any third parties present; Specialized •...
  • Page 21: Safety

    3 - SAFETY 3.1 - GENERAL SAFETY WARNINGS The equipment described in this manual is normally placed in systems that carry flammable gases (for exam- ple: natural gas). The user and installer of this device are required to comply with all national, state, and local laws required to avoid the hazards of gas leaks resulting from improper installation, startup, or use of this product or not de- scribed in the following manual.
  • Page 22: Safety Instructions

    3.2 - SAFETY INSTRUCTIONS SSm-icON 250 is an intrinsically safe apparatus suitable for use in hazardous areas class 1, Division 1, Group D, temperature class t3. the relevant standard for compliance with safety requirements is UL 913 intrinsically Safe Apparatus and Associated Appara- tus for Use in Class I, II, and III, Division 1, Hazardous (Classified) Locations, Edition 8, Revision Date 05/10/2022 3.2.1 - ELECTROSTATIC DISCHARGES...
  • Page 23: Safety Instructions For Installation In Hazardous Areas

    Any technical modification is forbidden. transport As a rule SSm-icON 250 should be transported upright and inside the original packing box provided by PiEtRO FiORENtiNi S.p.A. When you receive the apparatus, examine the material provided. Report any transportation damage immediately.
  • Page 24 • The arrow and "INLET" lettering located on the left front of the apparatus indicate the direction of gas flow and the gas inlet connection. • Install the apparatus in a compartment that meets current safety requirements, protected from possible mechanical damage, at least 3 ft away from heat sources or open flames, in a dry and ventilated place, and protected from external agents and corrosion.
  • Page 25: Compliance For United States Of America

    USA, Fcc class B-Part 15 the meter SSm-icON 250 has been tested and found to comply with the limits for class B digital devices pursuant to Part 15 of the Fcc standard. the limits are set to provide reasonable protection against harmful interference in a residential installation.
  • Page 26: Personal Protective Equipment

    3.6 - PERSONAL PROTECTIVE EQUIPMENT the following table shows the Personal Protective Equipment (PPE) and its description; an obligation is linked to each symbol. Personal protective equipment means any equipment intended to be worn by the worker for the purpose of protecting him against one or more hazards likely to threaten his safety or health while at work.
  • Page 27: Obligations And Prohibitions

    RESIDUAL RISKS The device SSM-ICON 250 is certified Class 1, Division 1, Group D and is approved for installations in high explosion hazard areas, i.e., areas where an explosive atmosphere consisting of a mixture of air and flammable substances in the form of gas, vapor or mist is present permanently or for long periods.
  • Page 28: Electrostatic Discharge Risk

    3.8.1 - ELECTROSTATIC DISCHARGE RISK in these areas, due to the presence of gases in the atmosphere, sparks produced by electrostatic discharges could still pro- duce explosions in extreme cases. Ensure that the area is not hazardous during installation, maintenance, cleaning or contact with the device. During installation, configuration and maintenance of the equipment, it is mandatory to implement electrostat- ic discharge protection measures.
  • Page 29: Security And Anti-Fraud

    3.9 - SECURITY AND ANTI-FRAUD Access to the internal parts of the device is protected. Any attempt at access causes obvious damage to mechanical parts, especially access: • to the electronics, this is not possible without permanent damage to the front cover of the device; •...
  • Page 30: Safety Pictograms

    SSm-icON 250 is a static meter and has no moving parts. For the generated noise value of the equipment and further information, please contact PiEtRO FiORENtiNi S.p.A. The obligation to use ear muffs or earplugs for hearing protection for licensed professionals (reference to paragraph 2.10) remains in case the noise in the environment where the equipment is installed (depending on...
  • Page 31: Description And Operation

    4 - DESCRIPTION AND OPERATION 4.1 - GENERAL DESCRIPTION The equipment SSM-ICON 250 is a static gas flow meter, which is applied at redelivery end points of gas networks. the meter integrates a static volume measurement sensor capable of: •...
  • Page 32: Power Devices

    4.1.1.1 - CONNECTION OF POWER DEVICES The equipment SSM-ICON 250 comes with the battery pack already connected and ready for use in the field. 4.1.1.2 - POWER STATUS A calculation of the actual consumption is made for each of the battery groups based on: •...
  • Page 33: Shut-Off Valve

    4.1.2 - SHUT-OFF VALVE The gas flow shut-off valve is located inside the meter body in the outlet connection and is intended to shut off the gas flow to the user. the valve is specially designed to guarantee its performance and operation for at least 20 years. It is mandatory that a technician be on site near the meter to reopen the valve and ensure safe conditions before gas flow is resumed after the valve is closed.
  • Page 34: Measurement Acquisition

    4.1.3 - MEASUREMENT ACQUISITION Gas volume flow (flow rate) is measured continuously by a special sensor, which is connected to the calculation board through an electrical connection. the governing microprocessor: • detects the measurements of the flow and temperature sensors (for possible compensation); •...
  • Page 35: Events And Diagnostics

    4.1.7 - EVENTS AND DIAGNOSTICS the equipment implements the following services: • detection and reporting of anomalies • functional requirements - event log • functional requirements - diagnostics and alarms • internal diagnostics function, which can be disabled via OBiS 4.1.7.1 - DEVICE DIAGNOSTICS the encoding of diagnostic information is carried out in bit-mapped format, as shown below in tab.
  • Page 36: Activation And Configuration

    4.1.8 - ACTIVATION AND CONFIGURATION the equipment implements the following services: • synchronization; • software update; • management and maintenance of the infrastructure; • functional requirements - programming; • functional requirements-field operations for startup and maintenance; • functional requirements - clock 4.1.9 - COMMUNICATION INTERFACE the equipment has two communication interfaces, one local and one remote: Interface...
  • Page 37: Intended Use

    Any other use of the equipment than that envisaged must be authorized in advance in writing by PiEtRO FiORENtiNi S.p.A. in the absence of written permission, the use is considered “improper”.
  • Page 38: Technical Data

    4.3 - TECHNICAL DATA General features Electronic enclosure Polycarbonate Enclosure protection rating iP68 (not UL tested) 3 ft/6 hr ; NEmA 4X Maximum working pressure 5 psig / 35 kPa Operating ambient temperature from -31 °F to +131 °F Gas temperature range from -31 °F to +131 °F Temperature sensor integrated...
  • Page 39: User Interface

    Long press (2 sec.): to access the next menu Long press (5 sec.): to activate wireless communication with devices equipped with tAm mobile application Tab. 5.23. Fig. 5.3. User interface SSM-ICON 250 StAtic SmARt mEtER USER iNtERFAcE REV. A Operation, maintenance and warning manual...
  • Page 40: Description Of Lcd Display

    To enable long battery life, the display is normally kept off. With the display off, to turn it on, press the "Enter" key for at least 1 sec. Fig. 5.4. LCD display SSM-ICON 250 tab. 5.24 describes the main elements on the display: Pos.
  • Page 41 Pos. Element Description CONSUMPTION INDICATOR FIELD Flame Indicates, if active, the presence of a current gas flow. NUMERIC FIELD Data indicates the value referring to the indicated parameter. Tab. 5.24. StAtic SmARt mEtER USER iNtERFAcE REV. A Operation, maintenance and warning manual...
  • Page 42: Browsing Procedure

    5.3 - BROWSING PROCEDURE • With the display on, the "Enter" key can be pressed in "short" or "long" mode (> 2 sec.). • The browse key is always activated in "short" mode. • Failure to press the button for more than 2 minutes switches the display to the off status.
  • Page 43: Main Menu

    5.3.1 - MAIN MENU While viewing the following chapter, the symbols shown in the “Active chapter Field” will all be off. the default chapter page display sequence is shown at tab. 5.25: Sequence Explanatory field Description totalizer t volume totalizer [ccF]. meter serial number Serial number of the device.
  • Page 44: Secondary Menu Selection

    5.3.2 - SECONDARY MENU SELECTION Use the browse key to scroll through the pages in the interface; then press the “Enter” key in long mode to access the specific page sequence of the desired sub menu. tab. 5.26 shows the display sequence of the sub menu pages. Main menu Secondary Menu Description...
  • Page 45: Alarms

    5.4 - ALARMS When the alarm icon on the display lights up this means that one or more of the following error conditions may be in progress according to the instrument configuration: • Volume measurement alarm • Alarm flow rate exceeding the stated maximum •...
  • Page 46 StAtic SmARt mEtER USER iNtERFAcE REV. A Operation, maintenance and warning manual...
  • Page 47: Transport And Handling

    • immediately report to PiEtRO FiORENtiNi S.p.A. any damage found. PIETRO FIORENTINI S.p.A. is not liable for damage to property or persons caused by accidents caused by failure to comply with the instructions given in this manual. StAtic SmARt mEtER tRANSPORt AND HANDLiNG REV.
  • Page 48: Package Contents

    PACKAGE CONTENTS the package contains: Content description Gas meter SSM-ICON 250 including 2 connection fitting protection caps. The batteries are already electrically connected internally in their place of operation. Tab. 6.30. The operation, maintenance and warning manual is downloadable from the Manufacturer’s website: https://www.fiorentini.com...
  • Page 49: Physical Characteristics Of The Equipment

    PHYSICAL CHARACTERISTICS OF THE EQUIPMENT Fig. 6.6. SSM-ICON 250 Standard Dimensions The height of meter SSM-ICON 250-U7 varies depending on the type of threading of the required process connections. See Tab. 6.31 for details on heights and weights for other available versions.
  • Page 50: Method For Anchoring And Lifting The Equipment

    6.4 - METHOD FOR ANCHORING AND LIFTING THE EQUIPMENT The use of lifting equipment (if required) for unloading, transporting and handling of packages is reserved only for qualified operators who have received adequate training and instruction (holding the appropriate license when regulations in the country of installation require it) and knowledgeable: •...
  • Page 51: Forklift Handling Method

    6.4.1 - FORKLIFT HANDLING METHOD It is forbidden to: • pass under suspended loads; • move the load over the personnel working in the site/plant area. On forklift trucks it is forbidden to: • transport passengers; • lift people. Use extreme care during all handling operations in order to avoid shock or vibration of equipment batteries. if the cardboard boxes (single or multiple) are supported by a pallet, proceed as shown in tab.
  • Page 52 Posizionare le forche del carrello elevatore sotto il piano del carico. Assicurarsi che le forche fuoriescano dalla parte anteriore del carico (almeno 5 cm), per una lunghezza Sollevare le forch su ciente ad eliminare eventuali rischi di ribaltamento della parte trasportata. Nota: se necessar Sollevare lentamente il carico di qualche decina di centimetri e veri carne la stabilità...
  • Page 53: Unpacking

    • do not perform the installation operations; • contact PIETRO FIORENTINI S.p.A. communicating the data shown on the identification plate of the equipment. The individual equipment is contained in a specially designed cardboard box. Avoid taking the equipment out of the box before installation.
  • Page 54: Storage And Environmental Conditions

    6.6 - STORAGE AND ENVIRONMENTAL CONDITIONS Protect the equipment also from accidental blows and shocks until it is installed. Meters should be stored in an upright position. the minimum environmental conditions expected if the equipment is to be stored for a long period are given in tab. 6.35. compliance with these conditions guarantees the stated performance: Terms and conditions Data...
  • Page 55: Installation

    It is forbidden to make changes to the equipment. PIETRO FIORENTINI S.p.A. shall not be liable for damage caused by improper installation of the equipment and/or otherwise different from what is stated in this manual.
  • Page 56: Checks Before Installation

    7.3 - CHECKS BEFORE INSTALLATION the place of installation must be suitable for safe use of the equipment. the equipment installation area should have lighting that provides the operator with good visibility during the installation steps. Before proceeding with installation you must make sure that: •...
  • Page 57: Installation-Specific Safety Warnings

    7.4 - INSTALLATION-SPECIFIC SAFETY WARNINGS The equipment comes with its battery packs already inserted and connected, so once installed, it is ready for use. Before proceeding with the installation phase, make sure that the upstream and downstream valves installed on the line are closed. The installation could also take place in environments at risk of explosion and this implies the adoption of all the necessary prevention and protection measures.
  • Page 58: Meter Installation Procedure

    Tighten the fittings to a torque that conforms to the type of meter connections (see references ANSI B109.1). Fill the meter SSM-ICON 250 slowly with distribution network pressure and check the connection fittings for tightness. The shut-off valve, located on the system upstream of the meter, should be opened gradually.
  • Page 59: Activation Procedure For The Acquisition Of Seismic Events

    "SEiSmic OFF" are displayed Failure of the activation procedure is due to the application of noncompliant stresses or the sys- tem where the meter is installed SSM-ICON 250 does not comply with the minimum requirements (ASCE 25-16).
  • Page 60: Equipment Adjustments

    7.7 - EQUIPMENT ADJUSTMENTS The equipment is adjusted as requested by the Customer directly at the factory PIETRO FIORENTINI S.p.A. No further adjustments need to be made. StAtic SmARt mEtER iNStALLAtiON REV. A Operation, maintenance and warning manual...
  • Page 61: Configuration

    VERIFICATION OF CORRECT CONFIGURATION Equipment verifications are carried out automatically by SAC. 8.4 - CONNECTING WITH OTHER DEVICES the connection of SSm-icON 250 with the SSm-cOm remote communication device or equivalent devices is intended. StAtic SmARt mEtER cONFiGURAtiON REV. A...
  • Page 62 StAtic SmARt mEtER cONFiGURAtiON REV. A Operation, maintenance and warning manual...
  • Page 63: Maintenance And Functional Testing

    Repair or maintenance work not provided for in this manual may be carried out only with prior approval from PIETRO FIORENTINI S.p.A.. No liability related to damage to persons or property can be attributed to PIETRO FIORENTINI S.p.A. for interventions other than those described or performed in a manner other than those indicated.
  • Page 64: Extraordinary Maintenance

    • torx t20 screwdriver; required • 2 screw cover seals provided by Pietro Fiorentini (see par. 11.3); • 2 self-tapping screws m4x12 (see par. 11.3). Tab. 9.42. The equipment is designed to ensure field replacement of the remote communication apparatus in the event of any depletion of battery power.
  • Page 65 StAtic SmARt mEtER mAiNtENANcE AND FUNctiONAL cHEcKS | REV. A Operation, maintenance and warning manual...
  • Page 66 Take care that the O-ring (D) on the communication module is properly installed. PIETRO FIORENTINI S.p.A. cannot be held responsible in case of malfunction to the optical com- munication between the meter SSM-ICON 250 and the SSM-COM communication device if the seal between the two modules is not fitted.
  • Page 67 Fig. 9.8. Replacement of the SSM-COM communication module StAtic SmARt mEtER mAiNtENANcE AND FUNctiONAL cHEcKS | REV. A Operation, maintenance and warning manual...
  • Page 68 StAtic SmARt mEtER mAiNtENANcE AND FUNctiONAL cHEcKS | REV. A Operation, maintenance and warning manual...
  • Page 69: Uninstallation And Disposal

    10 - UNINSTALLATION AND DISPOSAL 10.1 - GENERAL SAFETY WARNINGS Ensure that there are no effective ignition sources in the work area set up for equipment de-installation and/or disposal. 10.2 - QUALIFICATION OF THE OPERATORS IN CHARGE Uninstalling Operator qualification •...
  • Page 70: Information Needed In Case Of New Installation

    10.4 - INFORMATION NEEDED IN CASE OF NEW INSTALLATION In case the equipment after uninstallation is to be reused, refer to chapters: "Installation" and "Configuration". 10.5 - INFORMATION NEEDED IN CASE OF RE-INSTALLATION If the equipment needs to be reused after uninstallation, refer to chapter 7 “Installation”. StAtic SmARt mEtER UNiNStALLAtiON AND DiSPOSAL | REV.
  • Page 71: Disposal Information

    10.6 - DISPOSAL INFORMATION • Proper disposal avoids harm to humans and the environment and promotes the reuse of valuable raw materials. • Please remember to comply with the regulations in force in the country where the equipment is installed. •...
  • Page 72: Battery Disposal

    10.6.1 - BATTERY DISPOSAL Proceed with disposal in accordance with the rules: • of transport and packaging provided in the chapter; • of the regulations in force in the country where the equipment is installed. Take measures to prevent any leakage of contents from batteries under normal transport conditions. StAtic SmARt mEtER UNiNStALLAtiON AND DiSPOSAL | REV.
  • Page 73: Recommended Spare Parts

    By using non-recommended spare parts PIETRO FIORENTINI S.p.A. the stated performance cannot be guar- anteed. It is recommended to use the original PIETRO FIORENTINI S.p.A. spare parts PIETRO FIORENTINI S.p.A. is not responsible for damage caused by the use of non-original spare parts or components. 11.2 - HOW TO REQUEST SPARE PARTS For specific information, consult the PIETRO FIORENTINI S.p.A.
  • Page 74: Spare Parts List

    11.3 - SPARE PARTS LIST Spare parts are unambiguously identified by: • the location shown on the equipment assembly drawing (Fig. 11.9); • an identification code that associates the position with the component (Tab. 11.48). Reference the order codes for spare parts: Pos.
  • Page 75 StAtic SmARt mEtER REcOmmENDED SPARE PARtS | REV. A Operation, maintenance and warning manual...
  • Page 76 TM0065USA...