Operating Supplies; Cabling Requirements; Power Cable; Lvol To Interface Controller - Digital Equipment LV8 User Manual

Printer/plotter
Table of Contents

Advertisement

2.1.4
Operating Supplies
The
following
items
are
included with each LV01
unit:
One
(1) LV8/LV12/LV11
User's Guide
(DEC
no.
DEC-12-HLVAA-A-D)
One
(1) two-gallon
bottle of Toner Pre-Mix
(DEC
no.
49—01099)
One
(1) eight-ounce
bottle of Toner Concentrate
(DEC
no.
49-01100)
One
(1)
bottle of clear
dispersant
for
cleaning
purposes
(DEC
no.
49—01
101)
One
(1)
carton
of 1000 feet
continuous
form fanfold paper
(DEC
no.
36-11227—01)
Since
print
quality depends
on
the
type
and characteristics of paper and
toner
used,
supplies
furnished
by
DEC
are
recommended for proper
operation.
Performance
may
be
degraded
if other
supplies
are
used and machine
performance
cannot
be
guaranteed.
2.2
CABLING
REQUIREMENTS
2.2.1
Power Cable
A
7.5-foot power cord
is
permanently
attached
to
the LV01
at
the
rear
of the machine
adjacent
to
the fuse holder.
The cord for 60 Hz
systems
terminates in
a
standard
3-wire, male,
wall-type plug (NEMA 5-15P).
The cord for 50 Hz
systems
has
3
15A,
250V male
plug (NEMA 6-15P).
CAUTION
LV01 power
requirements
are
104—132
Vac, 3A,
47—63 Hz
or
208—264
Vac,
47—63
Hz,
600W maximum.
Prolonged
operation
above
or
below rated
voltages
may
cause
equipment
failure
and void the
warranty.
A 3-wire
(hot,
neutral,
ground)
receptacle
must
be available for proper power
application.
If
a
proper 3-wire
receptacle
is
not
available,
a
separate
wire
must
be connected from the LV01 chassis
to
"earth groun ".
WARNING
Do
not
work
on
the LV01 unit without
disconnecting
main
power
to
the machine. Make
sure
that the
safety
screen over
the power
supply
section
at
the
rear
of machine is
always
installed.
Dangerous voltages
of
approximately
1000V
are
present
in this section
during operation.
2.2.2
LV01
to
Interface Controller
The interface cable between the LV01 and the
respective
LVll
or
LV8 interface
is
shown
on
DEC
drawing
D-IA-7009133—0-0. The LV01
connects to
a
Cannon DCC-37P located
at
the lower left
corner on
the
rear
of the
LV01. The cable
terminates
at
the interface
in
a
Berg
connector
(DEC
no.
12-09941).
2.2.3
LVl
1,
LV8 Interface Controller Module
Mounting
The M7258 module
(LVll)
is
mounted
in
either
a
DDll-A
mounting
unit
or one
of the slots of the processor
mounting
box. Refer
to
the PDP-I 1
Peripherals
and
Interfacing
Handbook for detailed information
on
mounting
and
Unibus
connections.
24