Thank you for purchasing Niigata Seiki Digital Inside Calipers.
This is a precision measuring tool for measuring inside dimensions.
●For safe and proper use, please read this instruction manual before use and follow the procedures described.
Please keep manual where it is accessible to user for future reference.
●Keep this manual with the instrument if transferred or leased to a third party.
●For inquiries about this product, please contact dealer or Niigata Seiki.
■PART IDENTIFICATION AND FUNCTION
※Model
④Lock Screw
shown.
GDCS-150IK
③LCD Display
②Inside Jaws
① Inside Meas. Surfaces
①Inside Meas. Surfaces ...
Position surfaces inside object to be
measured.
②Inside Jaws ...............
For measuring inside dimensions.
③LCD Display ............
Displays digital measurement.
④Lock Screw ...............
Tighten to prevent the slide and display
from moving.
⑤ [ HOLD ] Button .........
When pressed, "HOLD" Icon appears on
Display and measurement will be fixed.
SAFETY PRECAUTIONS
To prevent harm to yourself or others, and to prevent damage to
property, always follow the procedures marked by the following
symbols.
WARNING
Indicates risk of personal injury or property damage if not followed.
Read the manual and follow the directions.
・Use of product other than as described in this
manual may cause accident.
Use only for measuring.
・Use for any purpose other than measuring may
damage or wear the instrument. Improper use may
also cause accident.
Handle with Care.
・Do not drop or subject instrument to excessive shock.
Do not place under heavy objects. Improper handling
may cause damage or poor accuracy.
・Do not scratch instrument, for example by writing ID
number.
Avoid using in high electric fields, such as near
fluorescent lights or switching power supplies.
・Incorrect value may be displayed on LCD.
GDCS - 150IK / GDCS - 200IK
Model No.
S
- Knife Edge Type
⑤ [ HOLD ] Button
⑥ Output Connector
⑩ Scale
⑦ Battery Cover
⑧ [ ZERO ] Button
⑨ [ ON/OFF ] Button
⑥Output Connector ...
Connect to optional BluetoothBOX
to send measurements to PC.
⑦Battery Cover .........
Open to access battery.
⑧ [ ZERO ] Button ......
When pressed, Display will read
"0.00"
⑨ [ ON/OFF ] Button ...
For turning power ON/OFF.
⑩Scale ..................
Supports LCD Display Unit.
Please Observe
Denotes a prohibition -
Denotes a requirement -
You MUST NOT do
You MUST do
Use and store only in environment meeting the
following conditions:
●Dry location protected from rain, water, and oils.
●Location that is not excessively hot.
●Location protected from use by children and
unauthorized people.
・Use in places contrary to the above may cause
damage to the product resulting in accident or injury.
Do not disassemble or modify.
・Disassembly may damage product or cause accident.
For repair, please contact distributor.
Do not write on instrument with electric engraver.
・Do not engrave instrument body or jaw, such as an ID
number with engraver or electric pen.
PREPARATION FOR USE
Before using the calipers, please follow the steps below:
●Wipe off rust proofing and dirt from measuring
surfaces and slide.
Contamination of surfaces may cause measurement error.
●Allow the calipers and object to be measured
time to reach the same temperature.
A temperature difference between the object to be
measured and the caliper may cause measurement error.
Allow enough time for the temperatures to equilibrate.
INSERTING・REPLACING BATTERY
①Slide cover in direction of arrow.
②Insert battery with (+) side outward.
③Replace battery cover.
Use only CR2032 type
Notice
battery.
Battery
●Use care to avoid damaging
Cover
terminals when inserting
battery.
●Terminals may be broken if battery is pressed straight
down.
●Insert battery at angle, underneath the small hook, as
shown.
Battery
Hook
Terminals
Terminals
TROUBLESHOOTING
Q. Nothing is displayed on LCD.
A. The battery may be running low, please replace
battery with a new one.
Q. With power on, the number on the LCD does not
change as Display Unit is moved.
A. Please reset by removing battery for about 30sec.,
and then replacing.
Q. Nothing happens when buttons are pressed.
A. Make sure battery is properly inserted.
Q. The characters "MIN", "MAX", or "△" are displayed
on LCD.
A. Cycle power, or apply several long presses to
[ HOLD ] Button. Use as normal once character is off.
Q. The correct value is not displayed.
A. High humidity may cause dampness. Please dry off
the instrument and use only in dry location.
SERVICE
●If Instrument is not working properly, or if you have any
questions, please contact distributor.
●Please note, manufacturer is unable to respond to
inquires or provide service directly. Please contact
distributor.
HOW TO USE
■Power ON/OFF
①To turn on, press the [ ON/OFF ] Button.
②To turn off, press the [ ON/OFF ] Button.
③With power on, press the [ HOLD ] Button to fix the value
on the display.
■Absolute Measurement Mode
①Loosen the lock screw, and turn on power.
②With jaws closed, press the [ ZERO ] Button.
③When "0.00mm" is displayed on LCD, Calipers is ready to
start measurement.
■Comparisons Measure Mode
①Loosen the lock screw, and turn on power.
②With jaws open to desired reference position ( any point
is OK, ) press [ ZERO ] Button.
③When "0.00mm" is displayed on LCD, Calipers is ready
to start measurement.
AFTER USE CARE・STORAGE
●After use, wipe off any dirt or oil from measuring
surfaces, sliding surfaces, and exterior using a
dry cloth and perform rust prevention treatment.
For rust prevention, lightly apply anti-rust oil, or place in
rust preventive bag.
●Store with Lock Screw loosened.
If stored with Lock Screw tight, expansion due to temperature
changes may cause excessive force which will cause
inaccuracy.
●Store in a cool, dry, and dark location in the
provided case.
Keep out of direct sunlight and moisture, and please keep
secure from unauthorized personnel.
●Remove battery if Caliper will not be used for a
long period of time.
Battery
Batteries may leak if left in unused instrument for an
extended period.
PRODUCT SPECIFICATIONS
Measurement
Jaw Length
Model
Range
GDCS - 150IK
15 - 150 mm
GDCS - 200IK
18 - 200 mm
●Resolution : 0.01mm
●Maximum permissible error :
±0.04 mm
※Not including quantization error ( ±1 count )
●Display
: 5 Digit LCD
●Auto Off
: approx. 20min.
●Maximum response speed : Slide to Right .....1.5m/s
Slide to Left ....... 0.75m/s
※Left/Right as shown in diagram at top of manual.
●Operating Temperature Range :
0° C 〜 40° C
●Storage Temperature Range
: −10° C 〜 60° C
●Power
: ( 1x ) CR2032 Lithium Battery
●Battery Life : approx. 2.5 years in normal use
●Accessory : CR2032 Lithium Battery ( for test )
Niigata seiki Co., Ltd.
5-3-14, Tsukanome, Sanjo, Niigata, Japan, 955-0055
Tel. : +81-256-33-5522 Fax. : +81-256-33-5518
MAIL intl.sales@niigataseiki.co.jp
URL
http://www.niigataseiki.co.jp
Weight
22 0 g
60 mm
26 0 g
75 mm

Advertisement

loading

Summary of Contents for Niigata seiki GDCS-150IK

  • Page 1 A temperature difference between the object to be ②With jaws closed, press the [ ZERO ] Button. ●For inquiries about this product, please contact dealer or Niigata Seiki. measured and the caliper may cause measurement error. ③When “0.00mm” is displayed on LCD, Calipers is ready to Allow enough time for the temperatures to equilibrate.
  • Page 2 なります。同じ温度になるよう、温度慣らしは十分に行って ●正しく安全にお使いいただくため、ご使用の前に本取扱説明書を必ず読み、記載の手順に従ってご使用ください。 ■絶対測定モード お読みになった後は、お使いになる方がいつでも見ることができる場所に大切に保管してください。 ください。 ①止めねじをゆるめ、 電源を入れてください。 ●第三者に譲渡・貸与される場合も、この説明書を必ず添付してください。 ②ノギスのジョウを閉じた状態で "ZERO"スイッチを押してくださ ●当商品に関するお問い合わせは、お買い求めの販売店もしくは当社にご連絡ください。 電池のセット・交換 い。 ■各部の名称と機能 ③LCD表示部に"0.00mm"が表示されると計測開始OKです。 ④止めねじ ⑤ HOLDスイッチ ※イラストはGDCS-150IKです。 ■比較測定モード ①電池蓋を矢印の向きに開けます。 ⑥出力コネクタ ③LCD表示部 ⑩ 本尺 ②電池を、必ず (+) 側を表にしてセッ ト ①止めねじをゆるめ、 電源を入れてください。 してください。 ②ノギスのジョウが開いた状態 (どのポイントでもOK) の時に ③電池蓋を元通りに装着してください。 "ZERO"スイッチを押してください。 電池は必ずCR2032をお ご注意 ③LCD表示部に"0.00mm"が表示されると計測開始OKです。...

This manual is also suitable for:

Gdcs-200ik