Precision Measuring Tool
For Wire Rope Diameter Measurements
WIRE ROPE CALIPERS
Thank you for purchasing Niigata Seiki Wire Rope Calipers.
This product is designed for precise and repeatable measurement of wire rope.
●For safe and proper use, please read this instruction manual before use and follow the procedures described.
Please keep manual where it is accessible to user for future reference.
●Keep this manual with the instrument if transferred or leased to a third party.
●For inquiries about this product, please contact dealer or Niigata Seiki.
■PART IDENTIFICATION AND FUNCTION
①Jaws
②Measuring Surfaces
⑨ [ ON/OFF ] Button
①Jaws ..........................................
For positioning outside of Wire Rope for measurement.
②Measuring Surfaces ........................
Surfaces for measuring Outside Diameter of Wire Rope.
③LCD Display .................................
Displays digital measurement.
④Lock Screw....................................
Tighten to prevent the slide and display from moving.
⑤ [ HOLD ] Button ..............................
When pressed, "HOLD"Icon appears on Display and measurement will be fixed.
⑥Output Connector ........................
Connect to optional BluetoothBOX to send measurements to PC.
⑦Battery Cover ..............................
Open to access battery.
⑧ [ ZERO ] Button..............................
When pressed, Display will read "0.00".
⑨ [ ON/OFF ] Button ...........................
For turning power ON / OFF.
⑩ Scale ..........................................
Supports LCD Display Unit.
SAFETY PRECAUTIONS
To prevent harm to yourself or others, and to prevent damage to
property, always follow the procedures marked by the following
symbols.
WARNING
Indicates risk of personal injury or property damage if not followed.
Read the manual and follow the directions.
・Use of product other than as described in this manual
may cause accident.
Use only for measuring.
・Use for any purpose other than measuring may
damage or wear the instrument. Improper use may
also cause accident.
Handle with Care.
・Do not drop or subject instrument to excessive shock.
Do not place under heavy objects. Improper handling
may cause damage or poor accuracy.
・Do not scratch instrument, for example by writing ID
number.
Avoid using in high electric fields, such as near
fluorescent lights or switching power supplies.
・Incorrect value may be displayed on LCD.
User Manual
GDCS - 100WR
Model No.
③ LCD Display
④Lock Screw
⑤ [ HOLD ] Button
⑥ Output Connector
⑩Scale
⑦ Battery Cover
⑧ [ ZERO ] Button
Please Observe
Denotes a prohibition -
Denotes a requirement -
You MUST NOT do
You MUST do
Use and store only in environment meeting the
following conditions:
●Dry location protected from rain, water, and oils.
●Location that is not excessively hot.
●Location protected from use by children and
unauthorized people.
・Use in places contrary to the above may cause
damage to the product resulting in accident or injury.
Do not disassemble or modify.
・Disassembly may damage product or cause accident.
For repair, please contact distributor or place of
purchase.
Do not write on instrument with electric engraver.
・Do not engrave instrument body or jaws, such as an ID
number with engraver or electric pen.
PREPARATION FOR USE
Before using the calipers, please follow the steps below:
●Wipe off rust proofing and dirt from measuring
surfaces and slide.
Contamination of surfaces may cause measurement error.
●Allow the calipers and object to be measured time to
reach the same temperature.
A temperature difference between the object to be measured
and the caliper may cause measurement error. Allow enough
time for the temperatures to equilibrate.
INSERTING・REPLACING BATTERY
① Slide cover in direction of arrow.
② Insert battery with (+) side outward.
③ Replace battery cover.
Use only CR2032 type
Notice
battery.
●Use care to avoid damaging
Battery
Cover
terminals when inserting
battery.
●Terminals may be broken if battery is pressed straight down.
●Insert battery at angle, underneath the small hook, as shown.
Battery
Hook
Terminals
Terminals
TROUBLESHOOTING
Q. Nothing is displayed on LCD.
A. The battery may be running low, please replace battery
with a new one.
Q. With power on, the number on the LCD does not change
as Display Unit is moved.
A. Please reset by removing battery for about 30sec., and
then replacing.
Q. Nothing happens when buttons are pressed.
A. Make sure battery is properly inserted.
Q. The characters "MIN", "MAX", or "△" are displayed on LCD.
A. Cycle power, or apply several long presses to [ HOLD ]
Button. Use as normal once character is off.
Q. The correct value is not displayed.
A. High humidity may cause dampness. Please dry off the
instrument and use only in dry location.
AFTER USE CARE・STORAGE
●After use, wipe off any dirt or oil from measuring
surfaces, sliding surfaces, and exterior using a dry
cloth and perform rust prevention treatment.
For rust prevention, lightly apply anti-rust oil, or place in rust
preventive bag.
●Store with Lock Screw loosened.
If stored with Lock Screw tight, expansion due to temperature
changes may cause excessive force which will cause inaccuracy.
●Store in a cool, dry, and dark location in the provided
case.
Keep out of direct sunlight and moisture, and please keep
secure from unauthorized personnel.
●Remove battery if Caliper will not be used for a long
period of time.
Batteries may leak if left in unused instrument for an extended
period.
HOW TO USE
■Power ON/OFF
①To turn on, press the [ ON/OFF ] Button.
②To turn off, press the [ ON/OFF ] Button.
③With power on, press the [ HOLD ] Button to fix the value on
the display.
■Absolute Measurement Mode
①Loosen the lock screw, and turn on power.
②With jaws closed, press the [ ZERO ] Button.
③When "0.00mm" is displayed on LCD, Calipers is ready to
start measurement.
■Comparisons Measure Mode
①Loosen the lock screw, and turn on power.
②With jaws open to desired reference position ( any point is
OK, ) press [ ZERO ] Button.
③When "0.00mm" is displayed on LCD, Calipers is ready to
start measurement.
×
Correct
Object to
Object to
Measure
Measure
Jaw
Battery
SERVICE
●If Instrument is not working properly, or if you have any
questions, please contact distributor or place of purchase.
●Please note, manufacturer is unable to respond to inquires or
provide service directly. Please contact distributor or place of
purchase.
PRODUCT SPECIFICATIONS
● Measuring Range : 0 -100mm
※For measuring rope of maximum diameter of 38mm.
● Resolution : 0.01mm
● Maximum Permissible Error : ±0.05mm
※Not including quantization error ( ±1 count )
● Display
: 5 Digit LCD
● Auto Off
: approx. 20 min.
● Maximum response speed : Slide to Right ..... 1.5 m/s
Slide to Left ....... 0.75 m/s
※Left/Right as shown in diagram at top of manual.
● Operating Temperature Range :
0° C ~40° C
● Storage Temperature Range
: −10° C ~60° C
● Power
: ( 1x ) CR2032 Lithium Battery
● Battery Life : approx. 2.5 years in normal use
● Weight
: 170g
● Accessory : CR2032 Lithium Battery ( for test )
Niigata seiki Co., Ltd.
5-3-14, Tsukanome, Sanjo, Niigata, Japan, 955-0055
Tel. : +81-256-33-5522 Fax. : +81-256-33-5518
MAIL intl.sales@niigataseiki.co.jp
URL
http://www.niigataseiki.co.jp
Wrong
Jaw

Advertisement

loading

Summary of Contents for Niigata seiki GDCS-100WR

  • Page 1 ②With jaws closed, press the [ ZERO ] Button. ●Keep this manual with the instrument if transferred or leased to a third party. INSERTING・REPLACING BATTERY ●For inquiries about this product, please contact dealer or Niigata Seiki. ③When “0.00mm” is displayed on LCD, Calipers is ready to start measurement.
  • Page 2 使用前の準備 使用方法 取扱説明書 品番 GDCS-100WR ワイヤーロープ径測定ノギス ■電源のON/OFF ご使用前に、下記の準備を行ってください。 ワイヤーロープ測定用 ●測定面、 摺動面、 外観などの汚れや防錆油などを拭き取る ①電源をONにするには、 ”ON/OFF”スイッチを押してください。 精密測定工具 そのまま測定を行うと誤差の原因となります。 ②電源をOFFにするには、 ”ON/OFF”スイッチを押してください。 ●本体と被測定物の温度慣らしを十分に行う ③電源ONの状態から“HOLD”スイッチを押すと数値が固定されます。 この度は「ワイヤーロープ径測定ノギス」をお買上げいただきありがとうございます。 測定器本体と被測定物の間に温度差があると、 誤差の原因となり この商品は、ワイヤーロープの径を安定して測定できる精密測定工具です。 ■絶対測定モード ます。 同じ温度になるよう、 温度慣らしは十分に行ってください。 ●正しく安全にお使いいただくため、ご使用の前に本取扱説明書を必ず読み、記載の手順に従ってご使用ください。 ①止めねじをゆるめ、 電源を入れてください。 電池のセッ ト ・ 交換 お読みになった後は、お使いになる方がいつでも見ることができる場所に大切に保管してください。 ②ノギスのジョウを閉じた状態で "ZERO"スイッチを押してください。 ●第三者に譲渡・貸与される場合も、この説明書を必ず添付してください。 ③LCD表示部に"0.00mm"が表示されると計測開始OKです。...