■PART IDENTIFICATION AND FUNCTION
③ LCD Display
②Jaws
① Probe Tips
① Probe Tips....................................
② Jaws ..........................................
③ LCD Display .................................
④ Lock Screw....................................
⑤ [ HOLD ] Button ..............................
⑥ Output Connector ........................
⑦ Battery Cover ..............................
⑧ [ ZERO ] Button..............................
⑨ [ ON/OFF ] Button ...........................
⑩ Scale ..........................................
SAFETY PRECAUTIONS
To prevent harm to yourself or others, and to prevent damage to
property, always follow the procedures marked by the following
symbols.
WARNING
Read the manual and follow the directions.
・Use of product other than as described in this manual
may cause accident.
Use only for measuring.
・Use for any purpose other than measuring may
damage or wear the instrument. Improper use may
also cause accident.
Handle with Care.
・Do not drop or subject instrument to excessive shock.
Do not place under heavy objects. Improper handling
may cause damage or poor accuracy.
・Do not scratch instrument, for example by writing ID
number.
Avoid using in high electric fields, such as near
fluorescent lights or switching power supplies.
・Incorrect value may be displayed on LCD.
User Manual
④ Lock Screw
⑧ [ ZERO ] Button
⑨ [ ON/OFF ] Button
Measuring surfaces which contact the workpiece.
For positioning on Object to be measured.
Displays digital measurement.
Tighten to prevent the slide and display from moving.
When pressed, "HOLD"Icon appears on Display and measurement will be fixed.
Connect to optional Bluetooth Box to send measurements to PC.
Open to access battery.
When pressed, Display will read "0.00".
For turning power ON / OFF.
Supports LCD Display Unit.
Indicates risk of personal injury or property damage if not followed.
Model No.
※Model GDCS-150NP Shown.
⑤ [ HOLD ] Button
⑥Output Connector
⑦Battery Cover
Please Observe
Denotes a prohibition -
You MUST NOT do
Use and store only in environment meeting the
following conditions:
●Dry location protected from rain, water, and oils.
●Location that is not excessively hot.
●Location protected from use by children and
unauthorized people.
・Use in places contrary to the above may cause
damage to the product resulting in accident or injury.
Do not use excessive force during measurement.
・The Probe Tips may be bent, causing inaccuracy.
Do not disassemble or modify.
・Disassembly may damage product or cause accident.
For repair, please contact distributor or place of
purchase.
Do not write on instrument with electric engraver.
・Do not engrave instrument body or jaws, such as an ID
number with engraver or electric pen.
GDCS - 150NP/GDCS - 200NP
⑩Scale
Denotes a requirement -
You MUST do

Advertisement

loading

Summary of Contents for Niigata seiki GDCS-150NP

  • Page 1 Please keep manual where it is accessible to user for future reference. ●Keep this manual with the instrument if transferred or leased to a third party. ●For inquiries about this product, please contact dealer or Niigata Seiki at the address listed on the following page. ■PART IDENTIFICATION AND FUNCTION ※Model GDCS-150NP Shown.
  • Page 2 ●Store in a cool, dry, and dark location in the provided case. Niigata seiki Co., Ltd. Keep out of direct sunlight and moisture, and please keep secure from unauthorized personnel. 6-15-22, Tsukanome, Sanjo, Niigata, Japan, 955-0055 ●Remove battery if Caliper will not be used for a long...

This manual is also suitable for:

Gdcs-200np