  • Page 1 7200 200-1000 V PRIME EN INSTALLATION, OPERATION AND MAINTENANCE MANUAL...
  • Page 2: Table Of Contents

    GENERAL INFORMATION GENERAL INFORMATION RANGE The following symbols are used in this manual: MODEL CODE CAUTION! = Identifies actions that require caution and ad- RIELLO 7200.200 V PRIME 20096892 equate preparation. RIELLO 7200.300 V PRIME 20096894 RIELLO 7200.430 V PRIME 20096895 STOP! = Identifies actions that you MUST NOT do.
  • Page 3: Precautions

    Never attempt to install the system without using suitable product. personal protection equipment and without following all applicable occupational safety standards. RIELLO S.p.A. Via Ing.Pilade Riello 7 37045 Legnago (VR) - ITALY Do not touch the product when barefoot or wet if it has any BOLLITORE T067773IFE...
  • Page 4: Structure, Dimensions And Fittings

    GENERAL INFORMATION GENERAL INFORMATION 4 STRUCTURE, DIMENSIONS AND FITTINGS (SB) Plug for anode inspection and lifting Magnesium anode Temperature gauge Plug for inspecting the second anode Storage cylinder Coil Bt Storage cylinder THERMOSTAT SENSOR or storage cylinder Adjustable foot TEMPERATURE SENSOR Insulation M Guide Cover...
  • Page 5: Technical Specifications

    GENERAL INFORMATION GENERAL INFORMATION 5 TECHNICAL SPECIFICATIONS 7200 V PRIME DESCRIPTION 1000 Type of storage cylinder Vitrified Storage cylinder layout Vertical Heat exchanger layout Vertical Storage cylinder capacity Diameter of storage cylinder with insulation 1000 Diameter of storage cylinder without insulation Height with insulation 1335 1835...
  • Page 6: Installation

    INSTALLATION INSTALLATION INSTALLATION 6 ASSEMBLY OF THE INSULATION AND THE LINING 7 PLACE OF INSTALLATION 7200 V PRIME 800 - 1000 7200 V PRIME storage cylinders can be installed in any room The assembly of the insulation and lining components must be where there is no specific requirement for an electrical protec- performed at the site of installation to facilitate passage through tion rating higher than IP X0D.
  • Page 7: Technical Assistance Service

    TECHNICAL ASSISTANCE SERVICE TECHNICAL ASSISTANCE SERVICE TECHNICAL ASSISTANCE SERVICE 8 MAINTENANCE MODELS 7200 V PRIME 800 - 1000 Removing and checking the second magnesium anode Perform the following operations before beginning any main- − Remove the plug (5) and use a suitable wrench to un- tenance: screw the anode holder (6).
  • Page 8 RIELLO S.p.A. Via Ing. Pilade Riello, 7 37045 - Legnago (VR) www.riello.com The manufacturer strives to continuously improve all products. Appearance, dimensions, technical specifications, standard equipment and accessories are therefore liable to modification without notice.