  • Page 1 PROMATRIX 9000 Public Address and Voice Alarm System Release notes...
  • Page 3: Table Of Contents

    PROMATRIX 9000 Table of contents | en Table of contents Introduction Document history Release history Scope Installation and configuration Supported products Release 1.70 Release 1.61 Release 1.60 Release 1.50 Release 1.42 Release 1.41 Release 1.40 Release 1.30 Release 1.20 Compliance to voice alarm standards Release 1.20...
  • Page 4 | Table of contents PROMATRIX 9000 Multiple redundant System controllers 6.10 DHCP server 6.11 Sticky faults 6.12 Multi-subnet 6.13 Firmware upload of CST and PRA-ANS with static IP-addresses Security precautions 2022-12 | V1.70 | Dynacord Release notes...
  • Page 5: Introduction

    PROMATRIX 9000 Introduction | en Introduction Document history Release date Documentation version Reason 2020-12 V1.20 edition 2021-06 V1.40 Chapters updated for release 1.40 2021-10 V1.41 Chapter updated: 1.1, 1.2, 2.2. Chapter added: 2.1, 3.3. 2021-12 V1.42 Chapter updated: 1.1, 1.2.
  • Page 6: Installation And Configuration

    PROMATRIX 9000 product section. When a PROMATRIX 9000 system is installed for voice alarm purposes, take notice of the installation and configuration directions in the checklist for compliance to the EN 54‑16 and EN 54‑4 standards. The checklist can be found at the end of the installation manual.
  • Page 7: Release

    – OMNEO platform upgrade to enable multi-VLAN support for PROMATRIX 9000. PROMATRIX 9000 can now be installed in networks that are divided by a router in multiple sub networks. – Support of OMN-ARNIE and OMN-ARNIS supervision. In case of redundant deployment, both the primary and the secondary devices are supervised.
  • Page 8: Release 1.41

    | Supported products PROMATRIX 9000 – In accordance with the North American standard for Mass Notification Systems, the software language set of English (UL 2572) has been revised and expanded in UL 2572 terminology. – The Call station indicator test has been extended to the LCD display, in cadence with the microphone LED ring, the display will show the identical colors.
  • Page 9 Refer to – Release 1.20, page 9 Release 1.30 Not published, release for internal purposes only. Release 1.20 The following PROMATRIX 9000 products can be installed and configured: PM9-SCL System controller, large PM9-AD604 Amplifier, 600 W 4‑channel PM9-AD608 Amplifier, 600 W 8‑channel PM9-EOL End‑of‑line device...
  • Page 10: Compliance To Voice Alarm Standards Release

    | Compliance to voice alarm standards PROMATRIX 9000 The following products can be used without need for configuration: PRA-PSM24 Power supply module 24 V PRA-PSM48 Power supply module 48 V The following products are already described in the installation manual and/or the...
  • Page 11: Release 1.40

    No new changes and/or additions. Release 1.50 Same compliances as Release 1.20, page 10 . For release 1.50, the PROMATRIX 9000 system has also been certified for EN54‑16 and ISO 7240‑169. Notice! In combination with the PROMATRIX 9000 system, the OMN-ARNIE, the OMN-ARNIS and the Cisco IE-5000-12S12P-10G switch are not certified with DNV-GL Type Approval.
  • Page 12: Fault Event - Temperature Too High

    | Notices PROMATRIX 9000 Fault event - Temperature too high If the amplifier detects temperature higher than +90 °C, the output level is attenuated by -3 dB in order to counteract this. The -3 dB attenuation is removed after the fault is acknowledged and reset.
  • Page 13: Static Ip In Fail Safe Mode

    IP. 4.12 ARNI V8.41 In a life safety system, version 1.61 of PROMATRIX 9000 cannot be used in combination with an 8.41 or early versions of the OMN-ARNIE/OMN-ARNIS devices. Missing functions System functions that are mentioned in the documentation, but have been postponed.
  • Page 14: Load Measurement

    For highest security, these Dante output channels in combination with System controller redundancy must not be used as part of the PROMATRIX 9000 system. Multiple redundant System controllers Release 1.20 is tested with one duty and one redundant System controller.
  • Page 15 This is also the case for PROMATRIX 9000 call stations that are connected via a single network cable. Make sure that the connector cover of the device is in place and properly fixed, to Dynacord 2022-12 | V1.70 |...
  • Page 16 They form a security risk, as no precautions are taken against malicious or accidental attacks through their network interfaces. For highest security, these Dante/AES67 devices should not be used as part of the PROMATRIX 9000 system. If such inputs or outputs are needed, use unicast connections.
  • Page 17 PROMATRIX 9000 Security precautions | en – In case a PC for event logs is used (PROMATRIX 9000 logging server and viewer), make sure that the PC is not accessible by unauthorized persons. – Do not leave unprotected call stations that can address a wide area on public accessible places.
  • Page 18 | Security precautions PROMATRIX 9000 2022-12 | V1.70 | Dynacord Release notes...
  • Page 20 Bosch Sicherheitssysteme GmbH Robert-Bosch-Ring 5 85630 Grasbrunn Germany www.dynacord.com © Bosch Sicherheitssysteme GmbH, 2022 202212191647...